NTIS 바로가기방사선기술과학 = Journal of radiological science and technology, v.46 no.3, 2023년, pp.187 - 195
정회원 (백석문화대학교 방사선학과) , 민정환 (신구대학교 방사선학과)
A shield was made by mixing materials such as bismuth(Bi) and barium(Ba) with silicon to evaluate its shielding ability. Bismuth was made into a shield by mixing a bismuth oxide(Bi2O3) colloidal solution and a silicon base and applied to a fibrous fabric, and barium was made by mixing lead oxide(PbO...
Song SK, Gil JW, Lee BY. Status of diagnostic X-ray?equipment in the Republic of Korea, 2021. Public?Health Weekly Report. 2022;15(51):3021-32.
Jang DG, Lee SH, Choi HS, Son JC, Toon CY, Ji?YS, et al. A study on the apron shielding ratio according to electromagnetic radiation energy. Journal of?Radiological Science and Technology. 2014;37(4):247-52.
Kwon YH. A study of MSDs and their policy reform?for workers in healthcare and medical fields [master's?thesis]. Seoul: Seoul Tech; 2009.
Matsuda M, Suzuki T. Evaluation of lead aprons and?their maintenance and management at our hospital.?J Anesth. 2016;30(3):518-21.
Park KY. Modification of lipoproteins by blood lead?(Pb) to result skin toxicity and pro-atherogenic effect?[master's thesis]. Gyeongbuk: Young-Nam Univ;?2014.
Korea Industry Society Association. Safety policy?against lead poisoning. KISA, 05; 1995.
Kim SC, Kim KT, Park JK. Barium compounds?through monte carlo simulations compare the performance of medical radiation shielding analysis.?Journal of the Korean Society of Radiology. 2013;7(6):403-8.
Kim SC, Park MH. Development of radiation shield with?environmentally-friendly materials; I: Comparison?and evaluation of fiber, rubber, silicon in the radiation shielding sheet. Journal of Radiological Science?and Technology. 2010;33(2):121-6.
Park HH, Lee JY, Kim JH. The usability evaluation?according to the application of bismuth shields in?PET/CT examination. Journal of Radiological Science?and Technology. 2014;37(1):49-56.
Jang SG, Han SC, Kang SJ, Lee SS. Preliminary?study for development of low dose radiation shielding material using liquid silicon and metalic?compound. Journal of Radiological Science and?Technology. 2017;40(3):461-8.
Korea Standard. Testing method of lead equivalent?for x-ray protective devices, No. 2015-0654. KSA 4025; 2017.
Ngaile JE, Uiso CBS, Msaki P, Kamena R. Use of?lead shields for radiation protection of superficial?organs in patients undergoing head CT examinations.?Radiation Protection Dosemetry. 2008;130(4):490-8.
Korean intellectual property office patent gazette(A),?Radiation shielding fabric. Number 10-08600332;?2008.
Korean intellectual property office patent gazette(A),?Radiation shielding fabric. Number 10-2009-0011082;?2009.
Choi TJ, Oh YK, Kim JH, Kim OB. Development?of lead free shielding material for diagnostic radiation beams. Medical Physics. 2010;21(2):232-7.
Park YS, Lee JS, Dong KR. Compare shielding performance evaluation of lead alternatives. Advanced?Engineering and Technology. 2015;8(1):79-85.
L HR. Preparation and characterization of X-ray?shielding materials by tungsten-silicon composites?[master's thesis]. Daegu: University of Keimyung;?2014.
Trapp JV, Kron T, Webster JG, Tabakov S, Ritenour?ER, Ng KH, et al. An introduction to radiation protection in medicine. Adelaide: Australasian Physical?& Engineering Sciences in Medicine; 2008.
Jeong HW, Kim JM, Lin SS. Broad beam transmission properties of some shielding materials for?use in diagnostic radiology. Journal of Radiological?Science and Technology. 2004;27(4):23-9.
National Council on Radiation Protection and?Measurements(NCRP). Structural shielding design?and evaluation for medical use of X rays and gamma?rays of energies up to 10 MeV. Bethesda: NCRP;?1976.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
Free Access. 출판사/학술단체 등이 허락한 무료 공개 사이트를 통해 자유로운 이용이 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.