최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기한국음향학회지= The journal of the acoustical society of Korea, v.42 no.3, 2023년, pp.203 - 213
이유림 (대진대학교 휴먼.로봇융합전공) , 정목근 (대진대학교 전자공학과)
In medical ultrasound imaging systems, Side lobes may appear if signals outside the imaging point are not completely removed during receive focusing. If the time signal of the side lobe overlaps with the time signal (main lobe) from the image point, it is difficult to completely remove it using filt...
J. A. Jensen and N. B. Svendsen, "Calculation of?pressure fields from arbitrarily shaped, apodized, and?excited ultrasound transducers," IEEE Trans. Ultrason.?Ferroelectr. Freq. Control, 39, 262-267 (1992).
D. A. Guenther and W. F. Walker, "Optimal apodization?design for medical ultrasound using constrained least?squares part II simulation results," IEEE Trans. Ultrason.?Ferroelectr. Freq. Control, 54, 343-358 (2007).
J. A. Mann and W. F. Walker, "A constrained adaptive?beamformer for medical ultrasound: Initial results,"?Proc. IEEE Ultrason. Symp. 2, 1807-1810 (2002).
J. F. Synnevag, A. Austeng, and S. Holm, "Benefits of?minimum-variance beamforming in medical ultrasound?imaging," IEEE Trans. Ultrason. Ferroelectr. Freq.?Control, 56, 1868-1879 (2009).
R. F. Wagner, M. F. Insana, and S. W. Smith, "Fundamental correlation lengths of coherent speckle in?medical ultrasonic images," IEEE Trans. Ultrason.?Ferroelectr. Freq. Control, 35, 34-44 (1988).
Y. Wang, H. Peng, C. Zheng, Z. Han, and H. Qiao, "A?dynamic generalized coherence factor for side lobe?suppression in ultrasound imaging," Comput. Biol.?Med. 116, 103522 (2020).
M. A. L. Bell, R. Goswami, J. A. Kisslo, J. J. Dahl, and?G. E. Trahey, "Short-lag spatial coherence imaging of?cardiac ultrasound data: Initial clinical results," Ultrasound Med. Biol. 39, 1861-1874 (2013).
M. A. L. Bell, J. J. Dahl, and G. E. Trahey, "Resolution?and brightness characteristics of short-lag spatial?coherence (SLSC) images," IEEE Trans. Ultrason.?Ferroelectr. Freq. Control, 62, 1265-1276 (2015).
T. A. Gallagher, A. J. Nemeth, and L. Hacein-Bey, "An?introduction to the Fourier transform: relationship to?MRI," Am. J. Roentgenol, 190, 1396-1405 (2008).
D. Gottleib, B. Gustafsson, and P. P. Forssen, "On the?direct Fourier method for computer tomography,"?IEEE Trans. Medical Imag. 19, 223-232 (2000).
M. M. Bronstein, A. M. Bronstein, M. Zibulevsky,?and H. Azhari, "Reconstruction in diffraction ultrasound tomography using nonuniform FFT," IEEE?T-MI, 21, 1395-1401 (2002).
W. F. Walker and G. E. Trahey, "The application of?k-space in pulse echo ultrasound," IEEE Trans. Ultrason.?Ferroelectr. Freq. Control, 45, 541-558 (1998).
K. Nagai, "A new synthetic-aperture focusing method?for ultrasonic B-scan imaging by the Fourier transform," IEEE Trans. Son. and Ultrason. 32, 531-536?(1985).
T. Stepinski, "An implementation of synthetic aperture?focusing technique in frequency domain," IEEE Trans.?Ultrason. Ferroelectr. Freq. Control, 54, 1399-1408?(2007).
M. K. Jeong, "A Fourier transform-based sidelobe?reduction method in ultrasound imaging," IEEE Trans.?Ultrason. Ferroelectr. Freq. Control, 47, 759-763 (2000).
M. K. Jeong and S. J. Kwon, "Estimation of side lobes?in ultrasound imaging systems," Biomed Eng. Lett. 5,?229-239 (2015).
M. K. Jeong, "Suppression of side lobe and grating?lobe in ultrasound medical imaging system" (in Korean),?J. Acoust. Soc. Kr. 41, 525-533 (2022).
A. Rodriguez-Molares, O. M. H. Rindal, J. D'hooge,?S. E. Masoy, A. Austeng, M. A. L. Bell, and H. Torp,?"The generalized contrast-to-noise ratio: A formal definition for lesion detectability," IEEE Trans. Ultrason.?Ferroelectr. Freq. Control, 67, 745-759 (2019).
R. F. Wagner, "Statistics of speckle in ultrasound?B-scans," IEEE Trans. Son. Ultrason. 30, 156-163?(1983).
T. A. Tuthill, R. H. Sperry, and K. J. Parker, "Deviations from Rayleigh statistics in ultrasonic speckle,"?Ultrasonic imaging, 10, 81-89 (1988).
M. K. Jeong and S. J. Kwon, "A new method for?assessing the performance of signal processing filters?in suppressing the side lobe level," USG, 40, 289-300?(2021).
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
오픈액세스 학술지에 출판된 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.