Purpose: As fire accidents happen at the production and storage sites of superabsorbent polymers for convenience of daily life, an experimental study was conducted to secure basic data to establish practical preventive measures against them. Method: The sample container (20cm width × 20cm len...
고흡수성 중합물질의 자연발화 한계온도를 구하기 위하여 용기의 충전상태를 변형하여 발화한계온도를 구하였다. 실험에 사용한 용기의 크기는 가로와 세로의 길이를 20cm×20cm로 하고 두께를 3cm, 5cm, 7cm, 14cm하여 시료의 충전상태에 따른 온도의 변화를 관찰하였으며, 자연발화한계온도의 결과를 Table 1에 나타내었다.
American Society for Testing and Materials (ASTM) (1998). Standard Test Method for Minimum Explosible?Combustible Dusts. ASTM E 1515-98, ASTM, West Conshohocken, PA.
Choi, I.G., Cho, I.K., Mok, Y.S., Lee, D.H., Choi, J.W., Ha, D.M. (1998). "The measurement of minimum ignition?energy and explosion limit for pine tree dust." The Korean Institute of Gas, Vol. 2, No. 2, pp. 55-60.
Choi, J.W., Mok, Y.S., Ha, D.M. (2001). "A study on spontaneous ignition of hydroxy propyl methyl cellulose."?Journal of Korean Institute of Fire Science and Engineering, Vol. 15, No. 4, pp. 34-40.
Choi, J.W., Mok, Y.S., Ok, G., Sagong, S.H. (1999). "A study on the spontaneous ignition of painting waste." The?Korean Society of Safety, Vol. 14, No. 2, pp. 90-96.
Choi, Y.J., Kim, J.H., Choi, J.W. (2017). "A study on the spontaneous ignition characteristics and fire risk of?commercial wood pellets." Korean Journal of Chemical Engineering, Vol. 55, No. 5, pp. 623-628.
Eckhoff, R.K. (2002). "Minimum Ignition Energy(MIE) - A basic ignition sensitivity parameter in design of?intrinsically safe electrical apparatus for explosive dust clouds." Journal of Prevention in the Process Industries, Vol.?15, pp. 305-310.
Frank-Kamenetskii, D.A. (1969). Diffusion and Heat Transfer in Chemical Kinetises. 2nd., Trans by Appleton,?Pleum Press, Princeton, New Jersey, pp. 5-36.
International Electrotechnicla Commission (IEC) (1994). Electrical Apparatus for Use in the Presence of Ignitable?Dust : Part2 ; Test Method, Section 3, Method for Determining the Minimum Ignition Energy of Dust/Air Mixtures.?IEC, Geneva.
International Standard Organization (ISO) (1985). Explosion Protection Systems-Part 1 : Determination of?Explosion Indices of Combustible Dusts in Air. ISO 6184/1.
Kim, K.S., Choi, Y.J., Choi, J.W. (2022). "An experimental study on the spontaneous ignition of flaxseed oil and?olive oil adsorbed on towels." Journal of the Society of Disaster Information, Vol. 18, No. 2, pp. 324-332.
Korea Occupational Safety and Health Agency (2013). Fire and Explosion Risk Assessment of PVC and SAP Dust.?Risk Assessment Report.
Lebecki, K., Dyduch, Z., Fibich, A., Sliz, J. (2003). "Ignition of a dust layer by a constant heat flux." Journal of Loss?Prevention in the Process Industries, Vol. 16, No. 4, pp. 243-248.
Lee, K.J. (2020). "A strategy of smart city growth through social and living lab." Journal of the Society of Disaster?Information, Vol. 16, No. 2, pp. 291-298.
Lu, P., Liao, G.X., Sun, J.H., Li, P.D. (2004). "Experimental research on index gas of the coal spontaneous at?low-temperature stage." Journal of Loss Prevention in the Process Industries, Vol. 17, pp. 243-247.
Mok, Y.S., Choi, J.W. (1992). "A study on auto ignition of granulated activated carbon with change of ambient temperature." The Korean Society of Safety, Vol. 7, No. 4, pp. 45-53.
Mok, Y.S., Choi, J.W. (2001). "A study on autoignition characteristics of methylmethacrylate-butadiene-styrene?copolymer." Journal of the Korean Society of Safety, Vol. 16, No. 3, pp. 83-88.
Pilao, R., Ramalho, E., Pinho, C. (2004). "Influence of initial pressure on the explosiblility of cork dust/air?mictures." Vol. 17, pp. 87-96.
Semenov, N.N. (1935). Chemical Kinetics and Chain Reactions. Oxford University Press, Oxford Oxfordshire.
Takeda H. (1976). "Theory of thermal ignition." Industrial Pyrotechnics Association, Vol. 38, No. 5, pp. 15-20.
THE FACT (2012). Fire at Japanese Superabsorbent Polymer (SAP) plant(hymeji workshop).
United National (1999). Recommendations on the Transport of Dangerous Goods. 11th Revised Edition, New York?and Geneva.?
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
오픈액세스 학술지에 출판된 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.