NTIS 바로가기한국방사선학회 논문지 = Journal of the Korean Society of Radiology, v.17 no.4, 2023년, pp.489 - 495
이기윤 (강원대학교 보건의료과학과) , 정경환 (강원대학교 보건의료과학과) , 한동희 (강원대학교 보건의료과학과) , 김장오 (강원대학교 방사선학과) , 한만석 (강원대학교 방사선학과) , 길종원 (질병관리청 의료안전예방국 의료방사선과) , 백철하 (강원대학교 보건의료과학과)
Radiation shielding facilities are constructed in locations where diagnostic radiation generators are installed, with the aim of preventing exposure for patients and radiation workers. The purpose of this study is seek to compare and validate the trend of attenuation thickness of lead, the primary m...
J. K. Shultis, R. E. Faw, "Radiation Shielding?Technology", Health Physics, Vol. 88, No. 4, pp.?297-322, 2005.
M. A. H. Abdullah, R. S. M. Rashid, M. Amran, F.?Hejazii, N. M. Azreen, R. Fediuk, Y. L. Voo, N. I.?Vatin, M. I. Idris, "Recent Trends in Advanced?Radiation Shielding Concrete for Construction of?Facilities: Materials and Properties", Polymers, Vol.?14, No. 14, pp. 2830, 2022.?https://doi.org/10.3390/polym14142830
F. H. Omoumi, X. Wu, M. U. Ghani, M. D. Wong,?Y. Li, H. Liu, "Mathematical estimation of half-value?layer thicknesses", Journal of Applied Clinical?Medical Physics, Vol. 22, No. 10, pp. 320-328,?2021. https://doi.org/10.1002/acm2.13385
Korea Medical Law, Safety Management of?Diagnostic Radiation Generators Rule, 2022.
National Committee on Radiation Protection (US),?Structural shielding design for medical x-ray imaging?facilities, NCRP, 2004.
D. G. Sutton, C. J. Martin, J. R. Williams, D. J.?Peet, Radiation Shielding for Diagnostic Radiology,?The British Institute of Radiology, 2012.
Radiological Protection Institute of Ireland, The?Design of Diagnostic Medical Facilities where?Ionising Radiation is used, Radiological Protection?Institute of Ireland, 2009.
J. H. Jung, "Location of radiation room and?shielding facility", Dental arirang, from URL;?https://www.dentalarirang.com/news/articleView.html?idxno28313
J. Y. Seo, "A policy to strengthen radiation defense?standards came out, but...", Dental arirang, from?URL;?https://www.dentalarirang.com/news/articleView.html?idxno22649
Food and Drug Administration, Guidelines for?Radiation Protection Facility Inspection, Ministry of?Health and Welfare, Korea,
T. Goorley, M. James, T. Booth, F. Brown, J. Bull,?L. J. Cox, J. Durkee, J. Elson, M. Fensin, R. A.?Forster, J. Hendricks, H. G. Hughes, R. Johns, B.?Kiedrowski, R. Martz, S. Mashnik, G. McKinney,?D. Pelowitz, R. Prael, J. Sweezy, L. Waters, T.?Wilcox, T. Zukaitis, "Initial MCNP6 release?overview", Nuclear technology, Vol. 180, No. 3,?pp. 298-315, 2012.?https://doi.org/10.13182/NT11-135
Y. H. Chung, C. H. Baek, S. J. Lee, "Monte Carlo?simulation codes for nuclear medicine imaging",?Nuclear Medicine and Molecular Imaging, Vol. 42,?No. 2, pp. 127-136, 2008.
T. Nowak, M. Hupfer, R. Brauweiler, F. Eisa, W.?A. Kalender, "Potential of high-Z contrast agents in?clinical contrast-enhanced computed tomography",?Medical physics, Vol. 38, No. 12, pp. 6469-6482,?2011. https://doi.org/10.1118/1.3658738
K. Cranley, B. J. Gilmore, G. W. A. Fogarty, L.?Deponds, Report 78 Catalogue of diagnostic X-ray?spectra and data, Institute of Physics and?Engineering in Medicine, York, Uk, 1997.
P. Schardt, J. Deuringer, J. Freudenberger, E. Hell,?W. Knupfer, D. Mattern, M. Schild, "New x-ray?tube performance in computed tomography by?introducing the rotating envelope tube technology",?Medical physics, Vol. 31, No. 9, pp. 2699-2706,?2004. https://doi.org/10.1118/1.1783552
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
Free Access. 출판사/학술단체 등이 허락한 무료 공개 사이트를 통해 자유로운 이용이 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.