최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기한국음향학회지= The journal of the acoustical society of Korea, v.42 no.5, 2023년, pp.429 - 440
이문환 (대구경북과학기술원 전기전자컴퓨터공학과) , 박희연 (대구경북과학기술원 전기전자컴퓨터공학과) , 이경수 (대구경북과학기술원 전기전자컴퓨터공학과) , 김세웅 (대구경북과학기술원 전기전자컴퓨터공학과) , 김지훈 (강남대학교 ICT융합공학부 전자공학전공) , 황재윤 (대구경북과학기술원 전기전자컴퓨터공학과)
This study explores recent research trends and potential applications of ultrasound optical imaging-based multimodal technology. Ultrasound imaging has been widely utilized in medical diagnostics due to its real-time capability and relative safety. However, the drawback of low resolution in ultrasou...
R. Guo, G. Lu, B. Qin, and B. Fei, "Ultrasound?imaging technologies for breast cancer detection and?management: A review," Ultrasound Med. Biol. 44,?37-70 (2018).
S.-F. Huang, R.-F. Chang, W. K. Moon, Y.-H. Lee,?D.-R. Chen, and J. S. Suri, "Analysis of tumor?vascularity using three-dimensional power Doppler?ultrasound images," IEEE Trans. Med. Imaging, 27,?320-330 (2008).
R. Y. Chiao and X. Hao, "Coded excitation for diagnostic ultrasound: a system developer's perspective,"?IEEE Trans. Ultrason. Ferroelectr. Freq. Control. 52,?160-170 (2005).
M. Freesmeyer, S. Wiegand, J.-H. Schierz, T. Winkens,?and K. Licht, "Multimodal evaluation of 2-D and 3-D?ultrasound, computed tomography and magnetic resonance imaging in measurements of the thyroid volume?using universally applicable cross-sectional imaging?software: a phantom study," Ultrasound Med. Biol.?40, 1453-1462 (2014).
F. Paparo, R. Piccazzo, L. Cevasco, A. Piccardo, F.?Pinna, F. Belli, L. Bacigalupo, E. Biscaldi, G. De Caro,?and G. A. Rollandi, "Advantages of percutaneous?abdominal biopsy under PET-CT/ultrasound fusion?imaging guidance: a pictorial essay," Abdom. Imaging,?39, 1102-1113 (2014).
F. Lindseth, J. H. Kaspersen, S. Ommedal, T. Lango,?J. Bang, J. Hokland, G. Unsgaard, and T. A. N. Hernes,?"Multimodal image fusion in ultrasound-based neuronavigation: improving overview and interpretation by?integrating preoperative MRI with intraoperative 3D?ultrasound," Comput. Aided Surg. 8, 49-69 (2003).
F. Hasford, J. Amuasi, A. Kyere, and M. Vangu,"?Ultrasound and PET-CT image fusion for prostate?brachytherapy image guidance," IAEA-CN-232, 47,?20-21 (2015).
J. M. Schmitt, "Optical coherence tomography (OCT):?A review," IEEE J. Sel. Topics. Quant. Electro. 5,?1205-1215 (1999).
J. Yin, H. C. Yang, X. Li, J. Zhang, Q. Zhou, C. Hu, K.?K. Shung, and Z. Chen, "Integrated intravascular optical?coherence tomography ultrasound imaging system," J.?Biomed. Opt. 15, 010512 (2010).
S. Liang, T. Ma, J. Jing, X. Li, J. Li, K. K. Shung, Q.?Zhou, J. Zhang, and Z. Chen, "Trimodality imaging?system and intravascular endoscopic probe: combined?optical coherence tomography, fluorescence imaging?and ultrasound imaging," Opt. Lett. 39, 6652-6655?(2014).
A. F. Kukk, D. Wu, E. Gaffal, R. Panzer, S. Emmert,?and B. Roth, "Multimodal system for optical biopsy of?melanoma with integrated ultrasound, optical coherence?tomography and Raman spectroscopy," J. Biophotonics,?15, e202200129 (2022).
H. Kang, X. Qian, R. Chen, R. Wodnicki, Y. Sun, R.?Li, Y. Li, K. K. Shung, Z. Chen, and Q. Zhou, "2-D?ultrasonic array-based optical coherence elastography,"?IEEE Trans. Ultrason. Ferroelectr. Freq. Control. 68,?1096-1104 (2020).
M. Xu and L. V. Wang, "Photoacoustic imaging in?biomedicine," Rev. Sci. Instrum. 77, 041101 (2006).
C. Kim, C. Favazza, and L. V. Wang, "In vivo photoacoustic tomography of chemicals: high-resolution?functional and molecular optical imaging at new?depths," Chem. Rev. 110, 2756-2782 (2010).
Y. Yang, X. Li, T. Wang, P. D. Kumavor, A. Aguirre,?K. K. Shung, Q. Zhou, M. Sanders, M. Brewer, and Q.?Zhu, "Integrated optical coherence tomography, ultrasound and photoacoustic imaging for ovarian tissue?characterization," Biomed. Opt. Express, 2, 2551-2561?(2011).
W. Wei, X. Li, Q. Zhou, K. K. Shung, and Z. Chen,?"Integrated ultrasound and photoacoustic probe for?co-registered intravascular imaging," J. Biomed. Opt.?16, 106001 (2011).
J.-M. Yang, C. Favazza, R. Chen, J. Yao, X. Cai, K.?Maslov, Q. Zhou, K.K. Shung, and L. V. Wang, "Simultaneous functional photoacoustic and ultrasonic?endoscopy of internal organs in vivo," Nat. Med. 18,?1297-1302 (2012).
Z. Wang, F . Yang, H. Ma, Z. Cheng, and S. Yang,?"Photoacoustic and ultrasound (PAUS) dermoscope?with high sensitivity and penetration depth by using a?bimorph transducer," J. Biophotonics, 13, e202000145?(2020).
S. Park, S. Kang, and J. H. Chang, "Optically transparent focused transducers for combined photoacoustic?and ultrasound microscopy," J. Med. Biol. Eng. 40,?707-718 (2020).
H. Chen, S. Agrawal, M. Osman, J. Minotto, S. Mirg,?J. Liu, A. Dangi, Q. Tran, T. Jackson, and S.-R.?Kothapalli, "A transparent ultrasound array for real-time optical, ultrasound, and photoacoustic imaging,"?BME Frontiers, 2022 1-14 (2022).
A. R. Valimukhametova, O. S. Zub, B. H. Lee, O. Fannon,?S. Nguyen, R. Gonzalez-Rodriguez, G. R. Akkaraju,?and A.V. Naumov, "Dual-mode fluorescence/ultrasound imaging with biocompatible metal-doped graphene?quantum dots," ACS Biomater. Sci Eng. 8, 4965-4975?(2022).
T. Yao, S. Yu, Y. Liu, and B. Yuan, "In vivo ultrasound-switchable fluorescence imaging," Sci. Rep. 9,?9855 (2019).
C. S. Snyder, S. Kaushal, Y. Kono, H. S. Tran Cao, R.?M. Hoffman, and M. Bouvet, "Complementarity of?ultrasound and fluorescence imaging in an orthotopic?mouse model of pancreatic cancer," BMC Cancer, 9,?106-115 (2009).
H. Estrada, J. Robin, A. Ozbek, Z. Chen, A. Marowsky,?Q. Zhou, D. Beck, B. le Roy, M. Arand, S. Shoham,?and D. Razansky, "High-resolution fluorescence-guided?transcranial ultrasound mapping in the live mouse?brain," Sci. Adv. 7, eabi5464 (2021).
P. Rauschendorfer, G. Wissmeyer, F. A. Jaffer, D.?Gorpas, and V. Ntziachristos, "Accounting for blood?attenuation in intravascular near-infrared fluorescence-ultrasound imaging using a fluorophore-coated guidewire," J. Biomed. Opt. 28, 046001 (2023).
H. Kim, S. Youn, J. Kim, S. Park, M. Lee, J. Y.?Hwang, and J. H. Chang, "Deep laser microscopy?using optical clearing by ultrasound-induced gas?bubbles," Nat. Phot. 16, 762-768 (2022).
D. Gorpas, H. Fatakdawala, J. Bec, D. Ma, D. R.?Yankelevich, J. Qi, and L. Marcu, "Fluorescence lifetime imaging and intravascular ultrasound: co-registration?study using ex vivo human coronaries," IEEE Trans.?Med. Imaging, 34, 156-166 (2015).
D. Ma, J. Bec, D. R. Yankelevich, D. Gorpas, H.?Fatakdawala, and L. Marcu, "Rotational multispectral?fluorescence lifetime imaging and intravascular ultrasound: bimodal system for intravascular applications,"?J. Biomed. Opt. 19, 066004 (2014).
H. Fatakdawala, S. Poti, F. Zhou, Y. Sun, J. Bec, J.?Liu, D. R. Yankelevich, S. P. Tinling, R. F. Gandour-Edwards, D. G. Farwell, and L. Marcu, "Multimodal?in vivo imaging of oral cancer using fluorescence?lifetime, photoacoustic and ultrasound techniques,"?Biomed. Opt. Express, 4, 1724-1741 (2013).
J. Kim, A. Seo, J. -Y. Kim, S. H. Choi, H .-J. Yoon, E.?Kim, and J. Y. Hwang, "A multimodal biomicroscopic?system based on high-frequency acoustic radiation?force impulse and multispectral imaging techniques?for tumor characterization ex vivo," Sci. Rep. 7,?17518 (2017).
J. Kim, H. M. Lew, J. -H. Kim, S. Youn, H. Al?Faruque, A. N. Seo, S. Y. Park, J. H. Chang, E. Kim,?and J. Y. Hwang, "Forward-looking multimodal endoscopic system based on optical multispectral and high-frequency ultrasound imaging techniques for tumor?detection," IEEE Trans. Med. Imaging, 40, 594-606?(2020).
O. Ronneberger, P. Fischer, and T. Brox. "U-net:?convolutional networks for biomedical image segmentation," Proc. MICCAI, 234-241 (2015).
Y. Guo, G. Wu, J. Stein, and A. Krishnamurthy, "SAU-Net: A universal deep network for cell counting," Proc.?10th ACM Int. Con. Bioinfo. Comput. Biol. Health?Info. 299-306 (2019).?
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
오픈액세스 학술지에 출판된 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.