최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기한국방사선학회 논문지 = Journal of the Korean Society of Radiology, v.17 no.6, 2023년, pp.1001 - 1007
서정민 (부산가톨릭대학교 방사선학과)
Dose limits are not applied to medical radiation exposure therefore justification and optimization should be essential for protecting radiation. This study explores methods to reduce exposure dose undergoing general radiation exam by bolus(tissue equivalent material) with keeping image quality. Hand...
E. Vano, D.L. Miller, C.J. Martin etc., Diagnostic?Reference Levels in Medical Imaging, ICRP No. 135,?2017.
Korea Center for Disease Control & Prevention,?Guidelines of Diagnositc Reference Level(General?Radiography), Ministry of Health and Welfare, Korea,?2019.
The Korean Society of Radiology, Final Report on?the Development of Evaluation Standards for?Appropriateness and Safety Management of Medical?Radiation in Diagnosis, Health Insurance Review &?Assessment Service in Korea, 2018
S. G. Shin, "Reducing Methods of Patient's Exposed?Dose Using Auto Exposure Control System in Digital?Radiography", Journal of Radiological Science and?Technology, Vol. 36, No. 2, pp. 111-122, 2013.
S. I. Shin, C. Y. Kim, S. C. Kim, "The Study on?the Reduction of Patient Surface Dose Through the?use of Copper Filter in a Digital Chest?Radiography", Journal of Radiological Science and?Technology, Vol. 31, No. 3, pp. 223-228, 2008.
J. H. Hwang, K. M. Jung, H. S. Kim, B. S. Kang,?K. B. Lee, "Dose Reduction According to the?Exposure Condition in Intervention Procedure : Focus?on the Change of Dose Area and Image Quality",?Journal of Radiological Science and Technology, Vol.?40, No. 3, pp. 393-400, 2017.?https://doi.org/10.17946/JRST.2017.40.3.06
D. W. Sung, "Radiation exposure in diagnostic?areas: issues and countermeasures", Journal of the?Korean Medical Association, Vol. 54, No. 12, pp.?1246-1247, 2011.?https://doi.org/10.5124/jkma.2011.54.12.1246
T. H. Lee, S. H. Jeong, D. W. Kim, M. H. Park,?T. H. Kim, "Radiation Protective Effect of the?Thyroid Gland Using Bolus Protector in the Dental?Cone Beam Computed Tomography", Journal of the?Korean Society of Radiology, Vol. 13, No. 3, pp.?459-464, 2019.?https://doi.org/10.7742/jksr.2019.13.3.459
H. L. Lee, H. W. Choi, H. Y. Kim, H. M. Lee, C.?S. Lim, "The Effects of a Thyroid Shield Made of?a Tissue-Equivalent Material on the Reduction of?the Thyroid Exposure Dose in Panoramic?Radiography", Journal of the Korea?Academia-Industrial cooperation Society, Vol. 13,?No. 5, pp. 2278-2284, 2012. https://doi.org/10.5762/KAIS.2012.13.5.2278
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
Free Access. 출판사/학술단체 등이 허락한 무료 공개 사이트를 통해 자유로운 이용이 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.