최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Medical physics, v.27 no.7, 2000년, pp.1503 - 1508
Baydush, Alan H. , Floyd Jr., Carey E.
Purpose: The effect of image processing, specifically Bayesian image estimation (BIE), on digital mammographic images is studied. BIE is an iterative, nonlinear statistical estimation technique that has previously been used in chest radiography to reduce image scatter content and improve the contras...
Boring, C. C., Squires, T. S., Tong, T., Montgomery, S.. Cancer statistics, 1994. CA: A Cancer Journal for Clinicians, vol.44, no.1, 7-26.
RCNA Tabar L. 187 30 1992 Update of the Swedish two‐county program of mammographic screening for breast cancer
Nystrom, L., Wall, S., Rutqvist, L.E., Lindgren, A., Lindqvist, M., Ryden, S., Andersson, J., Bjurstam, N., Fagerberg, G., Frisell, J., Tabar, L., Larsson, L.-G.. Breast cancer screening with mammography: overview of Swedish randomised trials. The Lancet, vol.341, no.8851, 973-978.
Shapiro, Sam. Screening: Assessment of current studies. Cancer, vol.74, no.1, 231-238.
Rutqvist, Lars E., Miller, Anthony B., Andersson, Ingvar, Hakama, Matti, Hakulinen, Timo, Sigfússon, Baldur F., Tabár, Làszlo. Chapter IV. Reduced breast-cancer mortality with mammography screening-an assessment of currently available data. International journal of cancer: Journal international du cancer, vol.46, no.suppl5, 76-84.
Muntz, E. P., Jafroudi, H., Jennings, R., Bernstein, H.. An approach to specifying a minimum dose system for mammography using multiparameter optimization techniques : Specifying a minimum dose system for mammography. Medical physics, vol.12, no.1, 5-12.
Bernstein, H., Muntz, E. P.. Experimental verification of a technique for predicting scattered radiation transfer: Application to low photon energies. Medical physics, vol.13, no.6, 836-842.
Barnes, G T. Contrast and scatter in x-ray imaging.. Radiographics : a review publication of the Radiological Society of North America, Inc, vol.11, no.2, 307-323.
Dance, D R, Day, G J. The computation of scatter in mammography by Monte Carlo methods. Physics in medicine & biology, vol.29, no.3, 237-247.
Yester, Michael V., Barnes, Gary T., King, Michael A.. Experimental measurements of the scatter reduction obtained in mammography with a scanning multiple slit assembly. Medical physics, vol.8, no.2, 158-162.
Klein, D. J., Chan, Heang‐Ping, Muntz, E. P., Doi, K., Lee, K., Chopelas, P., Bernstein, H., Lee, J.. Experimental and theoretical energy and angular dependencies of scattered radiation in the mammography energy range. Medical physics, vol.10, no.5, 664-668.
Australas. Phys. Eng. Sci. Med. Simeoni R. J. 33 16 1993 Scatter radiation in mammography
T. S. Curry III J. E. Dowdey and R. C. Murry Jr. Christensen's Introduction to the Physics of Diagnostic Radiology 4th ed. (Lea & Febiger Philadelphia 1990).
Radiol. Diagn. (Berlin) Waegner U. 465 31 1990 The reduction of radiation burden in mammography using film‐screen combination systems
Boone, John M., Shaber, Gary S., Tecotzky, Melvin. Dual‐energy mammography: A detector analysis. Medical physics, vol.17, no.4, 665-675.
Fahrig, Rebecca, Mainprize, James G., Robert, Normand, Rogers, Arthur, Yaffe, Martin J.. Performance of glass fiber antiscatter devices at mammographic energies. Medical physics, vol.21, no.8, 1277-1282.
Fahrig, Rebecca, Rowlands, J. A., Yaffe, Martin J.. X‐ray imaging with amorphous selenium: Optimal spectra for digital mammography. Medical physics, vol.23, no.4, 557-567.
Krol, A., Bassano, D. A., Chamberlain, C. C., Prasad, S. C.. Scatter reduction in mammography with air gap. Medical physics, vol.23, no.7, 1263-1270.
Muntz, EP, Logan, WW. Focal spot size and scatter suppression in magnification mammography. AJR : American journal of roentgenology, vol.133, no.3, 453-459.
Nielsen, B., Fagerberg, G.. Image Quality in Mammography with Special Reference to Anti-Scatter Grids and the Magnification Technique. Acta radiologica.: Diagnosis, vol.27, no.4, 467-479.
Nishikawa, Robert M., Mawdsley, Gordon E., Fenster, Aaron, Yaffe, Martin J.. Scanned‐projection digital mammography. Medical physics, vol.14, no.5, 717-727.
Thompson, C. J., Murthy, K., Weinberg, I. N., Mako, F.. Feasibility study for positron emission mammography. Medical physics, vol.21, no.4, 529-538.
Yester, Michael V., Barnes, Gary T., King, Michael A.. Experimental measurements of the scatter reduction obtained in mammography with a scanning multiple slit assembly. Medical physics, vol.8, no.2, 158-162.
LAM, KWOK LEUNG, CHAN, HEANG-PING. Exposure Equalization Technique in Mammography :. Investigative radiology, vol.24, no.2, 154-157.
Johns, Paul C., Drost, Dick J., Yaffe, Martin J., Fenster, Aaron. Dual‐energy mammography: Initial experimental results. Medical physics, vol.12, no.3, 297-304.
Med. Prog. Technol. Barnes G. T. 7 19 1993 Scanning slit mammography
Chen, Chin-Tu, Metz, Charles E.. A Simplified EM Reconstruction Algorithm for TOFPET. IEEE transactions on nuclear science, vol.32, no.1, 885-888.
Hebert, T., Leahy, R.. A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs priors. IEEE transactions on medical imaging, vol.8, no.2, 194-202.
J. Comput.‐Assist. Tomogr. Lange K. 306 8 1984 EM reconstruction algorithms for emission and transmission tomography
Shepp, L. A., Vardi, Y.. Maximum Likelihood Reconstruction for Emission Tomography. IEEE transactions on medical imaging, vol.1, no.2, 113-122.
Baydush, Alan H., Floyd Jr., Carey E.. Spatially varying Bayesian image estimation. Academic radiology, vol.3, no.2, 129-136.
Baydush, Alan H., Floyd Jr., Carey E.. Bayesian image estimation of digital chest radiography: Interdependence of noise, resolution, and scatter fraction. Medical physics, vol.22, no.8, 1255-1261.
FLOYD Jr, CAREY E., BAYDUSH, ALAN H., LO, JOSEPH Y., BROWSHER, JAMES E., RAVIN, CARL E.. Scatter Compensation for Digital Chest Radiography Using Maximum Likelihood Expectation Maximization :. Investigative radiology, vol.28, no.5, 427-433.
FLOYD Jr., CAREY E., BAYDUSH, ALAN H., LO, JOSEPH Y., BOWSHER, JAMES E., RAVIN, CARL E.. Bayesian Restoration of Chest Radiographs Scatter Compensation with Improved Signal-to-Noise Ratio :. Investigative radiology, vol.29, no.10, 904-910.
CHAN, HEANG-PING, VYBORNY, CARL J., MacMAHON, HEBER, METZ, CHARLES E., DOI, KUNIO, SICKLES, EDWARD A.. Digital Mammography : ROC Studies of the Effects of Pixel Size and Unsharp-Mask Filtering on the Detection of Subtle Microcalcifications. Investigative radiology, vol.22, no.7, 581-589.
Hale, Maj. Douglas A., Cook, Jay F., Baniqued, Zita, Silva‐Hale, Antonia, Molloy, Mark, Pearl, Richard H., Hadro, Neal C., Jaques, David P.. Selective digital enhancement of conventional film mammography. Journal of surgical oncology, vol.55, no.1, 42-46.
Puff, Derek T., Pisano, Etta D., Muller, Keith E., Johnston, R. Eugene, Hemminger, Bradley M., Burbeck, Christina A., McLelland, Robert, Pizer, Stephen M.. A method for determination of optimal image enhancement for the detection of mammographic abnormalities. Journal of digital imaging : the official journal of the Society for Computer Applications in Radiology, vol.7, no.4, 161-171.
Brailean, James C., Little, Darnell, Giger, Maryellen L., Chen, Chin‐Tu, Sullivan, Barry J.. Application of the EM algorithm to radiographic images. Medical physics, vol.19, no.5, 1175-1182.
Ned. Tijdschr. Geneeskd. Nab H. W. 2383 134 1990 Digital mammography is very useful in mass screening of breast cancer
Brettle, D S, Ward, S C, Parkin, G J S, Cowen, A R, Sumsion, H J. A clinical comparison between conventional and digital mammography utilizing computed radiography. The British journal of radiology, vol.67, no.797, 464-468.
Wang, Jun, Huang, H.K.. Film digitization aliasing artifacts caused by grid line patterns. IEEE transactions on medical imaging, vol.13, no.2, 375-385.
Baydush, Alan H., Bowsher, James E., Laading, Jacob K., Floyd Jr., Carey E.. Improved Bayesian image estimation for digital chest radiography. Medical physics, vol.24, no.4, 539-545.
Boone, John M., Arnold, Ben A., Seibert, J. Anthony. Characterization of the point spread function and modulation transfer function of scattered radiation using a digital imaging system. Medical physics, vol.13, no.2, 254-256.
Love, L. Alan, Kruger, Robert A.. Scatter estimation for a digital radiographic system using convolution filtering. Medical physics, vol.14, no.2, 178-185.
10.1111/j.2517-6161.1977.tb01600.x A. P. Dempster N. M. Laird and D. B. Rubin “Maximum likelihood from incomplete data via the EM algorithm ” J. R. Stat. Soc. London Series. B 1-38 (1977).
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.