최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Journal of structural engineering, v.126 no.9, 2000년, pp.1070 - 1077
Vecchio, F. J. (Prof., Dept. of Civ. Engrg., Univ. of Toronto, Toronto, ON, Canada M5S 1A4.)
A conceptual model is presented for describing the behavior of cracked reinforced concrete elements, representing a hybrid formulation between a fully rotating crack model and a fixed crack model. The formulation described builds on the concepts of the modified compression field theory, treating cracked concrete as an orthotropic material with unique stress-strain relationships in compression and tension. Advancements in the formulation, relative to the modified compression field theory, include a new approach to the reorientation of concrete stress and strain fields, removing the restriction that they be coincident, and an improved treatment of shear stresses on crack surfaces. New sets of equilibrium, compatibility, and constitutive relations are formulated accordingly, and alternative crack slip models are discussed. The proposed theory is shown to yield improved simulations of response in specific situations where the previous formulation was found to produce inaccuracies. This paper describes the formulation of the theory at the fundamental level.(Author abstract)
Ayoub, Amir, Filippou, Filip C.. Nonlinear Finite-Element Analysis of RC Shear Panels and Walls. Journal of structural engineering, vol.124, no.3, 298-308.
Bentz E. C. ( 1999). “Sectional analysis of reinforced concrete structures.” PhD thesis Dept. of Civ. Engrg. University of Toronto Toronto.
10.14359/3013 Bhide S. B. and Collins M. P. (1989). “Influence of axial tension on the shear capacity of reinforced concrete members.” ACI Struct. J. 86(5) 570-581.
“Design of concrete structures: Structures (design)-A national standard of Canada.” Canadian Standards Association (CSA) Committee A23.3. 1994 Canadian Standards Association (CSA) Committee A23.3. (1994). “Design of concrete structures: Structures (design)-A national standard of Canada.” Rexdale, Ont., Canada.
10.14359/9838 Collins M. P. Mitchell D. Adebar P. and Vecchio F. J. (1996). “A general shear design method.” ACI Struct. J. 93(1) 36-45.
Foster S. J. ( 1992). “The structural behavior of reinforced concrete deep beams.” PhD dissertation University of New South Wales New South Wales Australia.
Kaufmann, Walter, Marti, Peter. Structural Concrete: Cracked Membrane Model. Journal of structural engineering, vol.124, no.12, 1467-1475.
Okamura H. and Maekawa K. ( 1991). “Nonlinear analysis and constitutive methods of reinforced concrete.” ISBN 7655-1506-0 University of Tokyo Tokyo.
Vecchio, F. J.. Finite Element Modeling of Concrete Expansion and Confinement. Journal of structural engineering, vol.118, no.9, 2390-2406.
10.14359/839 Vecchio F. J. (2000). “Analysis of shear-critical reinforced concrete beams.” ACI Struct. J. 97(1) 102-110.
Vecchio, F. J., Collins, M. P.. Compression Response of Cracked Reinforced Concrete. Journal of structural engineering, vol.119, no.12, 3590-3610.
Vecchio F. J. Polak M. A. and Selby R. G. (1996). “Nonlinear analysis of reinforced concrete: The University of Toronto experience.” Proc. 3rd Asian-Pacific Conf. on Computational Mech.
Walraven, Joost C.. Fundamental Analysis of Aggregate Interlock. Proceedings of the American Society of Civil Engineers. Journal of the Structural Division, vol.107, no.11, 2245-2270.