Liu, Jing-Fu
(The Chinese Academy of Sciences, Research Center for Eco-Environmental Sciences, Beijing 100085, China)
,
Jiang, Gui-Bin
(The First Light Industry Institute of Beijing, No.7 Ju-Er Hutong, Beijing 100009, China)
,
Feng, Ying-Di
(The First Light Industry Institute of Beijing, No.7 Ju-Er Hutong, Beijing 100009, China)
AbstractA rapid and simple procedure was developed for the determination of copper, iron, manganese, and zinc in animal feeds using an identical flow injection spectrophotometric manifold but different chromogenic reagents and different detection wavelengths. Bis(cyclohexanone)oxalydihydrazone, form...
AbstractA rapid and simple procedure was developed for the determination of copper, iron, manganese, and zinc in animal feeds using an identical flow injection spectrophotometric manifold but different chromogenic reagents and different detection wavelengths. Bis(cyclohexanone)oxalydihydrazone, formaldoxime, 1,10-phenanthroline, and xylenol orange were adopted as chromogenic reagents for Cu, Mn, Fe, and Zn, respectively. Detection conditions such as manifold parameters, buffer pH, reagent concentration, temperature, and acidity of sample solution were optimized. Analytical characteristics of the method and interference of metal ions commonly present in feeds were studied. By changing the reagents and detection wavelengths, which can be done quickly, the proposed low cost flow injection system can determine Cu, Fe, Mn, or Zn in the range of 0.5-10 mg/L with a sampling throughput of 120/h.
AbstractA rapid and simple procedure was developed for the determination of copper, iron, manganese, and zinc in animal feeds using an identical flow injection spectrophotometric manifold but different chromogenic reagents and different detection wavelengths. Bis(cyclohexanone)oxalydihydrazone, formaldoxime, 1,10-phenanthroline, and xylenol orange were adopted as chromogenic reagents for Cu, Mn, Fe, and Zn, respectively. Detection conditions such as manifold parameters, buffer pH, reagent concentration, temperature, and acidity of sample solution were optimized. Analytical characteristics of the method and interference of metal ions commonly present in feeds were studied. By changing the reagents and detection wavelengths, which can be done quickly, the proposed low cost flow injection system can determine Cu, Fe, Mn, or Zn in the range of 0.5-10 mg/L with a sampling throughput of 120/h.
이 논문을 인용한 문헌
활용도 분석정보
상세보기
다운로드
내보내기
활용도 Top5 논문
해당 논문의 주제분야에서 활용도가 높은 상위 5개 콘텐츠를 보여줍니다. 더보기 버튼을 클릭하시면 더 많은 관련자료를 살펴볼 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.