최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Transfusion, v.40 no.11, 2000년, pp.1376 - 1383
Kumpel, Belinda M.
BACKGROUND: An analysis was carried out to determine the sources and extent of errors encountered in the quantitation of the volume of fetomaternal hemorrhage (FMH) by flow cytometry. Different assay conditions were compared, to define the simplest, most accurate protocol.STUDY DESIGN AND METHODS: D...
Tovey, L A. ABC of transfusion. Haemolytic disease of the newborn and its prevention.. BMJ : British medical journal, vol.300, no.6720, 313-316.
Letsky, E A, De Silva, M. Preventing Rh immunisation. BMJ : British medical journal, vol.309, no.6949, 213-214.
Nance, Sandra J., Nelson, Janice M., Arndt, Patricia A., Lam, Hwai-Tai C., Garratty, George. Quantitation of Fetal-Maternal Hemorrhage by Flow Cytometry: A Simple and Accurate Method. American journal of clinical pathology, vol.91, no.3, 288-292.
Immunohematology Nelson M 55 10 1994 10.21307/immunohematology-2019-819 Development of a flow cytometric test for the detection of D-positive fetal cells after fetomaternal hemorrhage and a survey of the prevalence in D-negative women.
Lloyd‐Evans, P., Kumpel, B. M., Bromelow, I., Austin, E., Taylor, E.. Use of a directly conjugated monoclonal anti‐D (BRAD‐3) for quantification of fetomaternal hemorrhage by flow cytometry. Transfusion, vol.36, no.5, 432-437.
Nelson, M., Zarkos, K., Popp, H., Gibson, J.. A Flow-Cytometric Equivalent of the Kleihauer Test. Vox sanguinis, vol.75, no.3, 234-241.
Davis, B.H., Olsen, S., Bigelow, N.C., Chen, JC.. Detection of fetal red cells in fetomaternal hemorrhage using a fetal hemoglobin monoclonal antibody by flow cytometry. Transfusion, vol.38, no.8, 749-756.
Wintrobe′s clinical haematology Perkins SL 2738 1999
Kelsey,, Reilly,, Chapman,, Bain,, Bates,, Knowles,, Shwe,, Parker‐Williams,, Robson,, Robson,, Bruce,, Chapman,, Duguid,, Knowles,, Murphy,, Williamson,, Cavill,, Wood,, Amos,, Bain,, Chapman,, Hyde,, Matutes,, Parker‐Williams,, Cavill,, Wood,. The estimation of fetomaternal haemorrhage. Transfusion medicine, vol.9, no.1, 87-92.
Kumpel, B.M., Austin, E.B., Lee, D., Jackson, D.J., Judson, P.A., Chapman, G.E.. Comparison of flow cytometric assays with isotopic assays of 51chromium‐labeled cells for estimation of red cell clearance or survival in vivo. Transfusion, vol.40, no.2, 228-239.
J Matern Fetal Invest Fung KAFK 121 8 1998 Clinical usefulness of flow cytometry in detection and quantification of fetomaternal hemorrhage.
McHugh, Thomas M., Reid, Marion E., Stites, Daniel P., Chase, Eric S., Casavant, Conrad H.. Detection of the Human Erythrocyte Surface Antigen Gerbich by Flow Cytometry using Human Antibodies and Phycoerythrin for Extreme Immunofluorescence Sensitivity. Vox sanguinis, vol.53, no.4, 231-234.
Gorick, B., McDougall, D. C. J., Ouwehand, W. H., Overbeeke, M. A. M., Tippett, P., Hughes‐Jones, N. C., van Rhenen, D. J.. Quantitation of D Sites on Selected ‘Weak D’ and ‘Partial D’ Red Cells. Vox sanguinis, vol.65, no.2, 136-140.
Mayne, K., Bowell, P., Woodward, T., Sibley, C., Lomas, C., Tippett, P.. Rh immunization by the partial D antigen of category DVa. British journal of haematology, vol.76, no.4, 537-539.
Jones, J.W., Lloyd-Evans, P., Kumpel, B.M.. Quantitation of Rh D Antigen Sites on Weak D and D Variant Red Cells by Flow Cytometry. Vox sanguinis, vol.71, no.3, 176-183.
Blood Kumpel BM 1701 86 1995 10.1182/blood.V86.5.1701.bloodjournal8651701 Human Rh D monoclonal antibodies (BRAD‐3 and BRAD‐5) cause accelerated clearance of Rh D+ red blood cells and suppression of Rh D immunization in Rh D- volunteers.
Garratty, G., Arndt, P.. Applications of flow cytofluorometry to transfusion science. Transfusion, vol.35, no.2, 157-178.
Hemolytic disease of the newborn Mollison PL 1 1984
Lubenko,, Williams,, Johnson,, Pluck,, Armstrong,, MacLennan,. Monitoring the clearance of fetal RhD‐positive red cells in FMH following RhD immunoglobulin administration. Transfusion medicine, vol.9, no.4, 331-335.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.