NTIS 바로가기Biosensors & bioelectronics, v.16 no.1/2, 2001년, pp.9 - 16
Han, Shubo (Department of Chemistry, Graduate School, University of Science and Technology of China, Chinese Academy of Sciences, Yuquan Road, 19A Box 3908, Beijing 100039, People's Republic of China) , Zhu, Min (Department of Chemistry, Graduate School, University of Science and Technology of China, Chinese Academy of Sciences, Yuquan Road, 19A Box 3908, Beijing 100039, People's Republic of China) , Yuan, Zhuobin (Department of Chemistry, Graduate School, University of Science and Technology of China, Chinese Academy of Sciences, Yuquan Road, 19A Box 3908, Beijing 100039, People's Republic of China) , Li, Xin (Department of Environmental Science, Hebei University of Science and Technology, Shijiazhuang 050018, People's Republic of China)
AbstractA methylene blue-mediated enzyme biosensor has been developed for the detection of inhibitors including mercury(II), mercury(I), methylmercury, and mercury–glutathione complex. The inhibition to horseradish peroxidase was apparently reversible and noncompetitive in the presence of HgC...
Electroanalysis Adeyoju 7 924 1995 10.1002/elan.1140071003 Kinetic characterizations of the effects of organic solvents on the performance of a peroxidase-modified electrode in detecting peroxides, thiourea and ethylenethiourea
Anal. Chim. Acta Adeyoju 305 1-3 57 1995 10.1016/0003-2670(94)00291-S Reactivities of amperometric organic phase peroxidase-modified electrodes in the presence and absence of thiourea and ethylene thiourea as inhibitors
Mikrochim. Acta Amine 121 183 1995 10.1007/BF01248250 Determination of mercury(II), methylmercury and ethylmercury in ng/ml range with an electrochemical enzyme glucose probe
Anal. Lett. Bogdanovskaya 27 2823 1994 10.1080/00032719408000295 Bioelectrocatalysis by immobilized peroxidase: the reaction mechanism and the possibility of electroanalytical detection of both inhibitors and activators of enzyme
Anal. Chem. Bontidean 70 9 4162 1998 10.1021/ac9803636 Detection of heavy metal ions at femtomolar levels using protein-based biosensors
Talanta Evtugyn 46 465 1998 10.1016/S0039-9140(97)00313-5 Sensitivity and selectivity of electrochemical enzyme sensors for inhibitor determination
Biosens. Bioelectron. Fennouth 13 7-8 903 1998 10.1016/S0956-5663(98)00062-1 Kinetic study of heavy metal salt effects on the activity of l-lactate dehydrogenase in solution or immobilized on an oxygen electrode
Biosens. Bioelectron. Gayet 8 177 1993 10.1016/0956-5663(93)85030-R Detection of heavy metal salts with biosensors built with an oxygen electrode coupled to various immobilized oxydases and dehydrogenases
Chem. J. Chin. Univ. Han 20 7 1036 1999 An amperometric hydrogen sensor based on supramolecular inclusion complex of β-CD polymer as immobilization matrix
Polymer J. Komiyama 19 773 1987 10.1295/polymj.19.773 Change in solutions of α- and β-cyclodextrins in water by complex formation with adamantanecarboxylate
FEBS Lett. Mattiasson 85 203 1978 10.1016/0014-5793(78)80455-4 Enzyme thermistor analysis of heavy metal ions with use of immobilized urease
Anal. Chim. Acta Ogren 96 1 1 1978 10.1016/S0003-2670(01)93389-6 Determination of traces of mercury(II) by inhibition of an enzyme reactor electrode loaded with immobilized urease
Biosens. Bioelectron. Preininger 11 10 981 1996 10.1016/0956-5663(96)87657-3 Disposable cuvette test with integrated sensor layer for enzymatic determination of heavy metals
Appl. Environ. Microbiol. Salifonova 59 9 3083 1993 10.1128/AEM.59.9.3083-3090.1993 Bioluminescent sensor for detection of bioavailable mercury(II) in the environment
Anal. Lett. Shekhovtsova 27 15 2883 1994 10.1080/00032719408000299 Determination of mercury at the picogram per milliliter levels using immobilized horseradish peroxidase
Anal. Chem. Smit 62 2429 1990 10.1021/ac00221a004 Cyanide detection using a substrate-regenerating peroxidase-based biosensor
Biotechnol. Bioeng. Tescione 42 8 945 1993 10.1002/bit.260420805 Construction and evaluation of a metal ion biosensor
Nippon Seramikkusu Kyokai Gakujutsu Ronbunshi Uo 100 430 1992 10.2109/jcersj.100.430 Preparation and properties of immobilized mercuric reductase in porous glass carriers
Anal. Chem. Virta 67 3 667 1995 10.1021/ac00099a027 A luminescence-based mercury biosensor
J. Am. Chem. Soc. Watton 112 7 2824 1990 10.1021/ja00163a067 Trigonal mercuric complex of an aliphatic thiolate: a spectroscopic and structural model for the receptor site in the Hg(II) biosensor Mer R
Fresenius J. Anal. Chem. Wollenberger 348 563 1994 10.1007/BF00323933 Enzyme and microbial sensors for phosphate, phenols pesticides and peroxides
Biosens. Bioelectron. Wong 12 2 125 1997 10.1016/S0956-5663(97)87058-3 A luminescence-based scanning respirometer for heavy metal toxicity monitoring
Rock Miner. Anal. Yuan 18 2 150 1999 Progress in the speciation of mercury in human body
Anal. Chim. Acta Yuan 389 291 1999 10.1016/S0003-2670(99)00134-8 Superamolecular inclusion complex formation and application of β-cyclodextrin heteroanthracene ring cationic dyes