최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Metrologia, v.57 no.2, 2020년, pp.025011 -
Damtew, Mulugeta Derebew (Korea Research Institute of Standards and Science (KRISS), Daejeon, Republic of Korea) , Kim, Min-Seok (Korea Research Institute of Standards and Science (KRISS), Daejeon, Republic of Korea)
Temperature and humidity sensitivity coefficients of torque transducers should be determined to improve the degree of equivalence among participants of key comparisons when torque transducers are used as transfer artifacts or secondary standards. Our experiments revealed that the temperature sensiti...
[1] Röske D 2009 Final report on the torque key comparison CCM.T-K1: measurand torque: 0 N·m, 500 N·m, 1000 N·m Metrol. Tech. Suppl. 46 07006 10.1088/0026-1394/46/1A/07002 Final report on the torque key comparison CCM.T-K1: measurand torque: 0 N·m, 500 N·m, 1000 N·m Röske D Metrol. Tech. Suppl. 46 07006 2009
[2] Brüge A 2014 Simplified measurements of the humidity coefficient of torque transducers in calibration laboratories Acta IMEKO 3 32–38 10.21014/acta_imeko.v3i2.80 Simplified measurements of the humidity coefficient of torque transducers in calibration laboratories Brüge A Acta IMEKO 0237-028X 3 2014 32 38
[3] Hoffmann K 1989 An introduction to measurements using strain gages (Dramstadt: Baldwin Messtechnik GmbH) 59–67 An introduction to measurements using strain gages (Dramstadt: Baldwin Messtechnik GmbH) Hoffmann K 1989 59 67
[4] Sanponpute T and Arksonnarong N 2014 Temperature and humidity dependence on stability of torque measuring devices IMEKO 22 Temperature and humidity dependence on stability of torque measuring devices Sanponpute T and Arksonnarong N IMEKO 22 2014
[5] Khaled K M, Röske D, Abuelezz A E and Elsherbiny M G 2015 Humidity and temperature effects on torque transducers, bridge calibration unit and amplifiers Measurement 74 31–42 10.1016/j.measurement.2015.07.007 Humidity and temperature effects on torque transducers, bridge calibration unit and amplifiers Khaled K M, Röske D, Abuelezz A E and Elsherbiny M G Measurement 74 2015 31 42
[7] Park Y-K, Kim M-S, Kim J-H, Choi J-H and Kang D-I 2007 Development of a small capacity deadweight torque standard machine Meas. Sci. Technol. 18 3273 10.1088/0957-0233/18/11/002 Development of a small capacity deadweight torque standard machine Park Y-K, Kim M-S, Kim J-H, Choi J-H and Kang D-I Meas. Sci. Technol. 0957-0233 18 11 002 2007 3273
[8] Kenney J F 1939 Mathematics of Statistics Part 2 78–83 Kenney J F Mathematics of Statistics 1939 78 83
[9] Devore J L and Berk K N 2012 Modern Mathematical Statistics with Applications 2nd edn (233 Spring Street, New York, NY 10013, USA: Springer Science+Business Media, LLC) 705–12 10.1007/978-1-4614-0391-3 Devore J L and Berk K N Modern Mathematical Statistics with Applications 1431-875X 2012 705 712
[10] BIPM, IEC, IFCC, ISO, IUPAC, IUPAP and OIML JCGM 100:2008 (GUM 1995 with minor corrections), Evaluation of measurement data — Guide to the Expression of Uncertainty in Measurement www.bipm.org/en/ publications/guides/gum.html BIPM, IEC, IFCC, ISO, IUPAC, IUPAP and OIML
[11] BIPM, IEC, IFCC, ISO, IUPAC, IUPAP and OIML JCGM 101:2008 Supplement 1 to the ‘Guide to the Expression of Uncertainty in Measurement’- Propagation of distributions using a Monte Carlo method www.bipm.org/en/publications/guides/gum.html BIPM, IEC, IFCC, ISO, IUPAC, IUPAP and OIML
해당 논문의 주제분야에서 활용도가 높은 상위 5개 콘텐츠를 보여줍니다.
더보기 버튼을 클릭하시면 더 많은 관련자료를 살펴볼 수 있습니다.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.