최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Veterinary sciences, v.8 no.3, 2021년, pp.40 -
Roh, Yoon Ho , Cho, Cheong Woon , Ryu, Chang Hun , Lee, Je Hun , Jeong, Seong Mok , Lee, Hae Beom
Corrective osteotomy has been applied to realign and stabilize the bones of dogs with lameness. However, corrective osteotomy for angular deformities requires substantial surgical experience for planning and performing accurate osteotomy. Three-dimensional printed patient-specific guides (3D-PSGs) w...
1. DeCamp C.E. Correction of Abnormal Bone Growth and Healing Brinker, Piermattei and Flo’s Handbook of Small Animal Orthopedics and Fracture Repair 5th ed. Piermattei D. Flo G. Brinker W. Elsevier Health Sciences Philadelphia, PA, USA 2016 791 796 9781437723649
2. Fox D.B. Tomlinson J.L. Principles of Angular Limb Deformity Correction Veterinary Surgery: Small Animal 2nd ed. Johnston S.A. Tobias K.M. Elsevier Health Sciences Philadelphia, PA, USA 2017 762 774 9780323320658
3. Imholt K. Möller S. Fehr M. Meyer-Lindenberg A. Lameness and osteoarthritis development following Tibial Plateau Leveling Osteotomy (TPLO) and potential prognostic predictors. A long-term retrospective study Tierarztl. Praxis. Ausg. K Kleintiere/Heimtiere 2011 39 323 335 10.1055/s-0038-1623596
4. Bäthis H. Perlick L. Tingart M. Perlick C. Lüring C. Grifka J. Intraoperative cutting errors in total knee arthroplasty Arch. Orthop. Trauma Surg. 2005 125 16 20 10.1007/s00402-004-0759-1 15538589
5. Caiti G. Dobbe J.G. Strijkers G.J. Strackee S.D. Streekstra G.J. Positioning error of custom 3D-printed surgical guides for the radius: Influence of fitting location and guide design Int. J. Comput. Assist. Radiol. Surg. 2018 13 507 518 10.1007/s11548-017-1682-6 29110185
6. Oka K. Murase T. Moritomo H. Goto A. Nakao R. Yoshikawa H. Sugamoto K. Accuracy of corrective osteotomy using a custom-designed device based on a novel computer simulation system J. Orthop. Sci. 2011 16 85 92 10.1007/s00776-010-0020-4 21359511
7. Dismukes D.I. Fox D.B. Tomlinson J.L. Essman S.C. Use of radiographic measures and three-dimensional computed tomographic imaging in surgical correction of an antebrachial deformity in a dog J. Am. Vet. Med Assoc. 2008 232 68 73 10.2460/javma.232.1.68 18167111
8. Hall E.L. Baines S. Bilmont A. Oxley B. Accuracy of patient-specific three-dimensional-printed osteotomy and reduction guides for distal femoral osteotomy in dogs with medial patella luxation Vet. Surg. 2019 48 584 591 10.1111/vsu.13126 30446995
9. Hoekstra H. Rosseels W. Sermon A. Nijs S. Corrective limb osteotomy using patient specific 3D-printed guides: A technical note Injury 2016 47 2375 2380 10.1016/j.injury.2016.07.021 27498242
10. Jaramaz B. Eckman K. 2D/3D registration for measurement of implant alignment after total hip replacement International Conference on Medical Image Computing and Computer-Assisted Intervention Springer Berlin/Heidelberg, Germany 2006 653 661
11. Sys G. Eykens H. Lenaerts G. Shumelinsky F. Robbrecht C. Poffyn B. Accuracy assessment of surgical planning and three-dimensional-printed patient-specific guides for orthopaedic osteotomies Proc. Inst. Mech. Eng. Part H J. Eng. Med. 2017 231 499 508 10.1177/0954411917702177 28639516
12. Hespel A.M. Wilhite R. Hudson J. Invited review-applications for 3D printers in veterinary medicine Vet. Radiol. Ultrasound 2014 55 347 358 10.1111/vru.12176 24889058
13. Oxley B. Bilateral shoulder arthrodesis in a Pekinese using three-dimensional printed patient-specific osteotomy and reduction guides Vet. Comp. Orthop. Traumatol. 2017 30 230 236 10.3415/VCOT-16-10-0144 28331927
14. Oxley B. Behr S. Stabilisation of a cranial cervical vertebral fracture using a 3D-printed patient-specific drill guide J. Small Anim. Pract. 2016 57 277 10.1111/jsap.12469 27004483
15. Schweizer A. Mauler F. Vlachopoulos L. Nagy L. Fürnstahl P. Computer-assisted 3-dimensional reconstructions of scaphoid fractures and nonunions with and without the use of patient-specific guides: Early clinical outcomes and postoperative assessments of reconstruction accuracy J. Hand Surg. 2016 41 59 69 10.1016/j.jhsa.2015.10.009
16. Easter T.G. Bilmont A. Pink J. Oxley B. Accuracy of three-dimensional printed patient-specific drill guides for treatment of canine humeral intracondylar fissure Vet. Surg. 2020 49 363 372 10.1111/vsu.13346 31713891
17. Elford J.H. Oxley B. Behr S. Accuracy of placement of pedicle screws in the thoracolumbar spine of dogs with spinal deformities with three-dimensionally printed patient-specific drill guides Vet. Surg. 2020 49 347 353 10.1111/vsu.13333 31617955
18. Pacchiana P.D. Morris E. Gillings S.L. Jessen C.R. Lipowitz A.J. Surgical and postoperative complications associated with tibial plateau leveling osteotomy in dogs with cranial cruciate ligament rupture: 397 cases (1998–2001) J. Am. Vet. Med. Assoc. 2003 222 184 193 10.2460/javma.2003.222.184 12555982
19. Cook J.L. Evans R. Conzemius M.G. Lascelles B.D.X. McIlwraith C.W. Pozzi A. Clegg P. Innes J. Schulz K. Houlton J. Proposed definitions and criteria for reporting time frame, outcome, and complications for clinical orthopedic studies in veterinary medicine Vet. Surg. 2010 39 905 908 10.1111/j.1532-950X.2010.00763.x 21133952
20. Swiderski J.K. Palmer R.H. Long-term outcome of distal femoral osteotomy for treatment of combined distal femoral varus and medial patellar luxation: 12 cases (1999–2004) J. Am. Vet. Med. Assoc. 2007 231 1070 1075 10.2460/javma.231.7.1070 17916032
21. Hudson J.T. Slater M.R. Taylor L. Scott H.M. Kerwin S.C. Assessing repeatability and validity of a visual analogue scale questionnaire for use in assessing pain and lameness in dogs Am. J. Vet. Res. 2004 65 1634 1643 10.2460/ajvr.2004.65.1634 15631027
22. Allpass M. Miles J.E. Case report-curved femoral osteotomy for management of medial patellar luxation Dan. Vet. 2015 98 32 36
해당 논문의 주제분야에서 활용도가 높은 상위 5개 콘텐츠를 보여줍니다.
더보기 버튼을 클릭하시면 더 많은 관련자료를 살펴볼 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.