최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine, v.46 no.5, 2001년, pp.1045 - 1048
Zhang, Xiaodong (Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota Medical School, Minneapolis, Minnesota) , Yacoub, Essa (Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota Medical School, Minneapolis, Minnesota) , Hu, Xiaoping (Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota Medical School, Minneapolis, Minnesota)
Most partial Fourier (PF) approaches use a low-resolution phase estimate in the reconstruction to account for non-zero phases of the image. These methods may fail when there are large phase errors, a situation commonly encountered in T*2-weighted functional MRI (fMRI). To mitigate this problem, a me...
Stenger, V. Andrew, Noll, Douglas C., Boada, Fernando E.. Partial fourier reconstruction for three‐dimensional gradient echo functional MRI: Comparison of phase correction methods. Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine, vol.40, no.3, 481-490.
Jesmanowicz, Andrzej, Bandettini, Peter A., Hyde, James S.. Single‐shot half k‐space high‐resolution gradient‐recalled EPI for fMRI at 3 tesla. Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine, vol.40, no.5, 754-762.
McGibney, G., Smith, M. R., Nichols, S. T., Crawley, A.. Quantitative evaluation of several partial fourier reconstruction algorithms used in mri. Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine, vol.30, no.1, 51-59.
Health Care Instrum Margosian P 195 1 1986 Faster MR imaging: imaging with half the data
Noll, D.C., Nishimura, D.G., Macovski, A.. Homodyne detection in magnetic resonance imaging. IEEE transactions on medical imaging, vol.10, no.2, 154-163.
Cuppen, J., van Est, A.. Reducing MR imaging time by one-sided reconstruction. Magnetic resonance imaging, vol.5, no.6, 526-527.
Haacke, E.M, Lindskogj, E.D, Lin, W. A fast, iterative, partial-fourier technique capable of local phase recovery. Journal of magnetic resonance, vol.92, no.1, 126-145.
Haacke, E. M.. Image reconstruction using POCS, model constraints, and linear prediction theory for the removal of phase, motion, and Gibbs artifacts in magnetic resonance and ultrasound imaging. Optical engineering : the journal of the Society of Photo-optical Instrumentation Engineers, vol.29, no.5, 555-.
Introduction to matrix computations Stewart GW 1973
Magnetic resonance imaging: physical principle and sequence design Haacke EM 1999
Hu, Xiaoping, Le, Tuong Huu, Parrish, Todd, Erhard, Peter. Retrospective estimation and correction of physiological fluctuation in functional MRI. Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine, vol.34, no.2, 201-212.
10.1002/(SICI)1522-2594(199910)42:4<636::AID-MRM4>3.0.CO;2-I
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
출판사/학술단체 등이 한시적으로 특별한 프로모션 또는 일정기간 경과 후 접근을 허용하여, 출판사/학술단체 등의 사이트에서 이용 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.