NTIS 바로가기Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine, v.86 no.5, 2021년, pp.2656 - 2665
Lee, Hyun‐Soo (MRI Laboratory, Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Korea) , Hwang, Seon‐Ha (MRI Laboratory, Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Korea) , Park, Jaeseok (Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Korea) , Park, Sung‐Hong (MRI Laboratory, Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Korea)
PurposeTo implement a single‐shot centric‐reordered EPI (1sh‐CenEPI), which reduces TE significantly, thus enabling to improve SNR for magnetization‐prepared imaging.MethodsWe proposed a 1sh‐CenEPI in which grouped oscillating readout gradients, phase‐encoding bli...
Edelman RR , Wielopolski P , Schmitt F . Echo‐planar MR imaging . Radiology . 1994 ; 192 : 600 ‐ 612 .
Turner R , Le Bihan D , Maier J , Vavrek R , Hedges LK , Pekar J . Echo‐planar imaging of intravoxel incoherent motion . Radiology . 1990 ; 177 : 407 ‐ 414 .
Poncelet BP , Koelling TM , Schmidt CJ , et al. Measurement of human myocardial perfusion by double‐gated flow alternating inversion recovery EPI . Magn Reson Med . 1999 ; 41 : 510 ‐ 519 .
Kwong KK . Functional magnetic resonance imaging with echo planar imaging . Magn Reson Q . 1995 ; 11 : 1 ‐ 20 .
Jezzard P , Clare S . Sources of distortion in functional MRI data . Hum Brain Mapp . 1999 ; 8 : 80 ‐ 85 .
Alsop DC , Detre JA , Golay X , et al. Recommended implementation of arterial spin‐labeled perfusion MRI for clinical applications: a consensus of the ISMRM perfusion study group and the European consortium for ASL in dementia . Magn Reson Med . 2015 ; 73 : 102 ‐ 116 .
Holsinger AE , Riederer SJ . The importance of phase‐encoding order in ultra‐short TR snapshot MR imaging . Magn Reson Med . 1990 ; 16 : 481 ‐ 488 .
Spincemaille P , Nguyen TD , Wang Y . View ordering for magnetization prepared steady state free precession acquisition: application in contrast‐enhanced MR angiography . Magn Reson Med . 2004 ; 52 : 461 ‐ 466 .
Feinberg DA , Hale JD , Watts JC , Kaufman L , Mark A . Halving MR imaging time by conjugation: demonstration at 3.5 kG . Radiology . 1986 ; 161 : 527 ‐ 531 .
Chen NK , Oshio K , Panych LP . Improved image reconstruction for partial Fourier gradient‐echo echo‐planar imaging (EPI) . Magn Reson Med . 2008 ; 59 : 916 ‐ 924 .
Kim SG , Hu X , Adriany G , Ugurbil K . Fast interleaved echo‐planar imaging with navigator: high resolution anatomic and functional images at 4 Tesla . Magn Reson Med . 1996 ; 35 : 895 ‐ 902 .
Lee HS , Choi SH , Park SH . Single and double acquisition strategies for compensation of artifacts from eddy current and transient oscillation in balanced steady‐state free precession . Magn Reson Med . 2017 ; 78 : 254 ‐ 263 .
Lee HS , Hwang S , Park J , Park SH . Single‐shot pseudo‐centric EPI for magnetization‐prepared imaging . In: Proceedings of the 28th Annual Meeting of ISMRM, virtual meeting, 2020 . Abstract #3735.
Bruder H , Fischer H , Reinfelder HE , Schmitt F . Image reconstruction for echo planar imaging with nonequidistant k‐space sampling . Magn Reson Med . 1992 ; 23 : 311 ‐ 323 .
Jezzard P , Balaban RS . Correction for geometric distortion in echo planar images from B0 field variations . Magn Reson Med . 1995 ; 34 : 65 ‐ 73 .
Buxton RB , Frank LR , Wong EC , Siewert B , Warach S , Edelman RR . A general kinetic model for quantitative perfusion imaging with arterial spin labeling . Magn Reson Med . 1998 ; 40 : 383 ‐ 396 .
Dolui S , Wang Z , Wang DJJ , et al. Comparison of non‐invasive MRI measurements of cerebral blood flow in a large multisite cohort . J Cereb Blood Flow Metab . 2016 ; 36 : 1244 ‐ 1256 .
Wang Y , Moeller S , Li X , et al. Simultaneous multi‐slice turbo‐FLASH imaging with CAIPIRINHA for whole brain distortion‐free pseudo‐continuous arterial spin labeling at 3 and 7 T . Neuroimage . 2015 ; 113 : 279 ‐ 288 .
Chen X , Zhu A , Du YP . Center‐out EPI (COEPI): a fast single‐shot imaging technique with a short TE . Magn Reson Med . 2020 ; 84 : 787 ‐ 799 .
Morgan PS , Bowtell RW , McIntyre DJ , Worthington BS . Correction of spatial distortion in EPI due to inhomogeneous static magnetic fields using the reversed gradient method . J Magn Reson Imaging . 2004 ; 19 : 499 ‐ 507 .
해당 논문의 주제분야에서 활용도가 높은 상위 5개 콘텐츠를 보여줍니다.
더보기 버튼을 클릭하시면 더 많은 관련자료를 살펴볼 수 있습니다.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.