최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology, v.5 no.4, 1995년, pp.239 - 243
Oberg, T. (Department of Biomechanics and Orthopaedic Technology, University College of Health Sciences, Jonkoping, Sweden)
Amplitude electromyography (EMG) is often used as an estimator of muscular load. Such measurements can, however, be biased by other factors, for example muscular fatigue. The aim of this study was to examine the influence of fatigue on amplitude parameters of the EMG. The test subjects raised the...
Arvidsson 1982 A statistical method for detecting disturbances and nonstationary events in stochastic signals with special reference to data selection in EEC and EMG analysis
Basmajian 1985
CRC Crit Rev Biomed Eng DeLuca 11 251 1984 Myoelectrical manifestation of localized muscular fatigue in humans
Edwards 1981 Human muscle fatigue: Physiological mechanisms Human muscle function and fatigue
Ergonomics Hagg 30 1541 1987 10.1080/00140138708966046 A worksite method for shoulder muscle fatigue measurements using EMG test contractions and zero crossing technique
Kadefors 10 273 1983 Computer-aided electromyography EMG data processing in ergonomics, with emphasis on studies of shoulder muscle load
Kadefors 433 1992 Computer applications in ergonomics, occupational safety and health A portable device for ambulatory assessment of workload from electromyographic signals
Knaflitz 321 1991 Electromyographical kinesiology Motor unit recruitment order in voluntary and electrically elicited contractions
J Sci Labour (Tokyo) Kogi 38 519 1962 Frequency analysis of the surface electromyogram in muscle fatigue
J Electromyogr Kinesiol Merletti 1 20 1991 10.1016/1050-6411(91)90023-X Indices of muscle fatigue
Ergonomics Mirka 34 343 1991 10.1080/00140139108967318 The quantification of EMG normalization error
Eur J Appl Physiol Oberg 61 362 1990 10.1007/BF00236054 EMG mean power frequency in non-fatigued trapezius muscle
J Electromyogr Kinesiol Oberg 1 237 1991 10.1016/1050-6411(91)90010-3 Variability of the EMG mean power frequency: A study on the trapezius muscle
Electromyogr Clin Neurophysiol Oberg 32 87 1992 Arm movement and EMG mean power frequency in the trapezius muscle: A comparison between surface and intramuscular recording techniques
Clin Biomech Oberg 9 253 1994 10.1016/0268-0033(94)90007-8 EMG mean power frequency and the need for a reference value
Ergonomics Suurkula 30 1553 1987 10.1080/00140138708966047 Relations between shoulder-neck disorders and EMG zero crossings shift in female assembly workers using the test contraction method
해당 논문의 주제분야에서 활용도가 높은 상위 5개 콘텐츠를 보여줍니다.
더보기 버튼을 클릭하시면 더 많은 관련자료를 살펴볼 수 있습니다.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.