NTIS 바로가기IEEE transactions on nuclear science, v.52 no.1 pt.1, 2005년, pp.217 - 221
Chung, Yong Hyun (Dept. of Nucl. Medicine, Sungkyunkwan Univ., Seoul, South Korea) , Choi, Yong , Cho, Gyuseong , Choe, Yearn Seong , Lee, Kyung-Han , Kim, Byung-Tae
Phoswich detectors for small animal PET have been developed to measure the depth of interaction and to improve resolution performances. The aim of this study was to perform simulations to design the optimum lengths of crystals composing a dual layer phoswich detector. A simulation tool, the Geant4 Application for Tomographic Emission (GATE), was used and validated against a commercially available small animal PET using a dual layer phoswich detector. The newly designed small PET system employed cerium doped lutetium oxyorthosilicate (LSO) -cerium doped lutetium-yttrium aluminum perovskite (LuYAP) phoswich detector modules, which consisted of 8×8 arrays of dual layer crystals, with a 2×2 mm sensitive area, coupled to a Hamamatsu R7600-00-M64 position sensitive photomultiplier tube (PSPMT). The sensitivities and variations of the radial resolutions were simulated by varying the length of the LSO front layer from 0 to 10 mm, while the total length (LSO+LuYAP) was fixed to 20 mm for 10 and 19 cm diameter ring scanners. The results support the validity of the simulation tool. The radial resolution uniformity was markedly improved using the depth of interaction (DOI) information, and the optimal lengths of the crystal layers for minimizing the variation of the radial resolutions also existed. In the 10 cm ring scanner configuration, the radial resolution was kept below 3.4 mm, over 8 cm field of view (FOV), while the sensitivity was higher than 7.4% for the LSO 5 mm : LuYAP 15 mm phoswich detector. The resolution variations were minimized to less than 3.6 mm, over 16 cm FOV, using a LSO 6 mm : LuYAP 14 mm phoswich detector for the 19 cm ring scanner. In this study, the optimal length of the dual layer phoswich detector was derived to achieve a high and uniform radial resolution.
Shao, Y., Silverman, R.W., Farrell, R., Cirignano, L., Grazioso, R., Shah, K.S., Vissel, G., Clajus, M., Tumer, T.O., Cherry, S.R.. Design studies of a high resolution PET detector using APD arrays. IEEE transactions on nuclear science, vol.47, no.3, 1051-1057.
Moisan, C., Andreaco, M.S., Rogers, J.G., Paquet, S., Vozza, D.. Segmented LSO crystals for depth-of-interaction encoding in PET. IEEE transactions on nuclear science, vol.45, no.6, 3030-3035.
Murayama, H., Ishibashi, I., Uchida, H., Omura, T., Yamashita, T.. Depth encoding multicrystal detectors for PET. IEEE transactions on nuclear science, vol.45, no.3, 1152-1157.
IEEE MIC Rec resolution uniformity and sensitivity of the nih atlas small animal pet scanner: comparison to simulated lso scanner without depth-of-interaction capability seidel 2001 m9a 5
Santin, G., Strul, D., Lazaro, D., Simon, L., Krieguer, M., Martins, M.V., Breton, V., Morel, C.. GATE: a Geant4-based simulation platform for PET and SPECT integrating movement and time management. IEEE transactions on nuclear science, vol.50, no.5, 1516-1521.
GEANT4 A Simulation Toolkit 2002
Melcher, C.L., Schweitzer, J.S.. Cerium-doped lutetium oxyorthosilicate: a fast, efficient new scintillator. IEEE transactions on nuclear science, vol.39, no.4, 502-505.
Moszyński, M, Wolski, D, Ludziejewski, T, Kapusta, M, Lempicki, A, Brecher, C, Wiśniewski, D, Wojtowicz, A.J. Properties of the new LuAP:Ce scintillator. Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, vol.385, no.1, 123-131.
Zaidi, Habib. Relevance of accurate Monte Carlo modeling in nuclear medical imaging. Medical physics, vol.26, no.4, 574-608.
Streun, M., Brandenburg, G., Larue, H., Saleh, H., Zimmermann, E., Ziemons, K., Halling, H.. Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET. IEEE transactions on nuclear science, vol.50, no.3, 344-347.
Bartzakos, P., Thompson, C.J.. A depth-encoded PET detector. IEEE transactions on nuclear science, vol.38, no.2, 732-738.
Dahlbom, M., MacDonald, L.R., Eriksson, L., Paulus, M., Andreaco, M., Casey, M.E., Moyers, C.. Performance of a YSO/LSO phoswich detector for use in a PET/SPECT system. IEEE transactions on nuclear science, vol.44, no.3, 1114-1119.
Seidel, J., Vaquero, J.J., Siegel, S., Gandler, W.R., Green, M.V.. Depth identification accuracy of a three layer phoswich PET detector module. IEEE transactions on nuclear science, vol.46, no.3, 485-490.
Yamamoto, S., Ishibashi, H.. A GSO depth of interaction detector for PET. IEEE transactions on nuclear science, vol.45, no.3, 1078-1082.
IEEE MIC Rec design optimization of the pmt-clearpet prototypes based on simulation studies with geant3 heinrichs 2002 m3 26
J Nucl Med performance evaluation of micropet: a high-resolution lutetium oxyorthosilicate pet scanner for animal imaging chatziioannou 1999 1164
Balaban, R. S., Hampshire, V. A.. Challenges in Small Animal Noninvasive Imaging. ILAR journal, vol.42, no.3, 248-262.
Moses, W.W., Derenzo, S.E., Melcher, C.L., Manente, R.A.. A room temperature LSO/PIN photodiode PET detector module that measures depth of interaction. IEEE transactions on nuclear science, vol.42, no.4, 1085-1089.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.