NTIS 바로가기Journal of quantitative spectroscopy & radiative transfer, v.105 no.2, 2007년, pp.303 - 311
Reichert, L. (Institute of Environmental Physics, University of Bremen, Otto Hahn Allee, 1, 28359 Bremen, Germany) , Andres Hernandez, M.D. , Burrows, J.P. , Tikhomirov, A.B. , Firsov, K.M. , Ptashnik, I.V.
Measurements of near-infrared water vapour continuum using continuous wave cavity ring down spectroscopy (cw-CRDS) have been performed at around 10611.6 and 10685.2cm-1. The continuum absorption coefficients for N2-broadening have been determined to be CF296K=(1.0+/-0.2)x10-24cm2mol-1atm-1 and CF278...
Science Arking 273 779 1996 10.1126/science.273.5276.779 Absorption of solar energy in the atmosphere: discrepancy between model and observations
Atmos Res Tipping 36 69 1995 10.1016/0169-8095(94)00028-C Theory of the water vapor continuum and validations
J Chem Phys Ma 92 10 7066 1990 10.1063/1.459429 The atmospheric water continuum in the infrared: extension of the statistical theory of Rosenkranz
J Chem Phys Ma 111 13 5909 1999 10.1063/1.479886 The average density matrix in the coordinate representation: application to the calculation of the far-wing line shapes for H2O
J. Chem. Phys. Ma 1166 10 4102 2002 10.1063/1.1436115 The frequency detuning correction and the asymmetry of line shapes: the far wings of H2O-H2O
Atmos Res Clough 23 229 1989 10.1016/0169-8095(89)90020-3 Line shape and the water continuum
Mlawer EJ, Clough SA, Brown PD, Tobin DC. Recent developments in the water vapor continuum. Nineth ARM Science Team Meeting Proceedings, March 22-26; 1999.
Mlawer EJ, Tobin DC, Clough SA. A revised perspective on the water vapor continuum: the MT_CKD model. JQSRT, in preparation.
Radio Sci Rosenkranz 33 4 919 1998 10.1029/98RS01182 Water vapour microwave continuum absorption: a comparison of measurements and models
Appl Opt Grant 29 4 451 1990 10.1364/AO.29.000451 Water vapour absorption coefficients in the 8-13mm spectral region: a critical review
JQSRT Kratz 90 323 2005 10.1016/j.jqsrt.2004.04.006 An inter-comparison of far-infrared line-by-line radiative transfer models
Appl Opt Tobin 35 24 4724 1996 10.1364/AO.35.004724 Experimental investigation of the self- and N2-broadened continuum within the ν2 band of water vapor
JQSRT Fomin 86 73 2004 10.1016/S0022-4073(03)00275-9 Evolution of spectroscopic information over the last decade and its effect on line-by-line calculations for validation of radiation codes for climate models
JQSRT Vogelmann 60 2 231 1998 10.1016/S0022-4073(97)00151-9 Observational constraints on non-Lorentzian continuum effects in the near-infrared solar spectrum using ARM ARESE data
10.1029/2003JD003586 Sierk B, Solomon S, Daniel JS, Portmann RW, Gutman SI, Langford AO, et al. Field measurements of water vapour continuum absorption in the visible and near-infrared. J Geophys Res 2004;109:D08307, doi:10.1029/2003JD003586.
J Chem Phys Cormier 116 3 1030 2002 10.1063/1.1425825 Cavity ringdown spectroscopy measurements of the infrared water vapor continuum
J Chem Phys Cormier 122 114 2005 10.1063/1.1862623 Infrared water vapor continuum absorption at atmospheric temperatures
J Mol Spectrosc Aldener 232 223 2005 10.1016/j.jms.2005.04.011 Near-IR absorption of water vapor: pressure dependence of line strengths and an upper limit for continuum absorption
Opt Spectrosc Tikhomirov 101 1 80 2006 10.1134/S0030400X06070150 Measurements of the continuum absorption coefficient of water vapour near 14400cm-1(0.694μm)
J Opt Soc Am Fulghum 8B 2401 1991 10.1364/JOSAB.8.002401 Interferometric calorimeter for the measurement of water vapour absorption
Quart J R Meteorol Soc Ptashnik 130 2391 2004 10.1256/qj.03.178 Laboratory measurements of water vapour continuum absorption in the spectral region 5000-5600cm-1: evidence for water dimers
Chem Phys Lett Romanini 264 316 1997 10.1016/S0009-2614(96)01351-6 CW cavity ring down spectroscopy
Chem Phys Lett Romanini 270 538 1997 10.1016/S0009-2614(97)00406-5 Diode laser cavity ring down spectroscopy
Chem Phys Lett Romanini 270 546 1997 10.1016/S0009-2614(97)00407-7 Cavity ring down spectroscopy: broad band absolute absorption measurements
Reichert L, Andres-Hernandez MD, Burrows JP. Methodologies to retrieve precise spectroscopic parameters for weak water absorption features in close vicinity to strong absorption lines, manuscript in preparation.
ESA SP-1279(3) WALES-Water Vapour Lidar, Reports for mission selection. The six candidate Earth explorer missions. Experiment in Space. ESA Publications Division, ISBN 92-9092-962-6, ISSN 0379-6566; 2004.
Atmos Oceanic Opt Mitsel’ 8 10 847 1995 Efficient technique for line-by-line calculating the transmittance of the absorbing atmosphere
JQSRT Rothman 96 2 139 2005 10.1016/j.jqsrt.2004.10.008 The HITRAN 2004 Molecular Spectroscopic Database
10.1016/j.jqsrt.2007.03.011 Ptashnik IV. Evaluation of suitable spectral intervals for near-IR laboratory detection of water vapour continuum absorption. JQSRT 2006, submitted for publication.
J Mol Spectrosc Malathy Devi 117 403 1986 10.1016/0022-2852(86)90163-3 Diode laser measurements of air and nitrogen broadening in the ν2 bands of HDO, H216O and H218O
J Opt Soc Am Gasster B5 593 1988 10.1364/JOSAB.5.000593
J Mol Spectrosc Grossmann 138 562 1989 10.1016/0022-2852(89)90019-2 Water line broadening and shifting by air, nitrogen, oxygen, and argon in the 720-nm wavelength region
J Mol Spectrosc Mandin 138 272 1989 10.1016/0022-2852(89)90117-3 N2 broadening coefficients of H216O lines between 9500 and 11500cm-1
JQSRT Varanasi 38 6 407 1987 10.1016/0022-4073(87)90094-X Self- and N2-broadened spectra of water vapour between 7.5 and 14.5mm
Phys Chem Chem Phys Schofield 5 3100 2003 10.1039/b304952c Calculated OH-stretching and HOH-bending vibrational transitions in the water dimmer
Burch DE. Continuum absorption by H2O. Air Force Geophysics Laboratory Report, AFGL-TR-81-0300, Hanscom AFB, MA; 1981.
J Phys Chem A Goldman 108 787 2004 10.1021/jp035360y Water dimers in the atmosphere II: results from the VRT(ASP-W)III potential surface