최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Physics in medicine & biology, v.53 no.1, 2008년, pp.77 - 88
Mu, G , Ludlum, E , Xia, P
The dosimetric impact of random and systematic multi-leaf collimator (MLC) leaf position errors is relatively unknown for head and neck intensity-modulated radiotherapy (IMRT) patients. In this report we studied 17 head and neck IMRT patients, including 12 treated with simple plans (100 segments). R...
Bayouth, J. E., Wendt, D., Morrill, S. M.. MLC quality assurance techniques for IMRT applications. Medical physics, vol.30, no.5, 743-750.
Chuang, Cynthia F., Verhey, Lynn J., Xia, Ping. Investigation of the use of MOSFET for clinical IMRT dosimetric verification. Medical physics, vol.29, no.6, 1109-1115.
Dutreix, J., Tubiana, M., Dutreix, A.. An approach to the interpretation of clinical data on the tumour control probability-dose relationship. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology, vol.11, no.3, 239-248.
Esthappan, Jacqueline, Mutic, Sasa, Harms, William B., Dempsey, James F., Low, Daniel A.. Dosimetry of therapeutic photon beams using an extended dose range film. Medical physics, vol.29, no.10, 2438-2445.
LoSasso, Thomas, Chui, Chen‐Shou, Ling, C. Clifton. Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode. Medical physics, vol.28, no.11, 2209-2219.
Low, Daniel A., Mutic, Sasa, Dempsey, James F., Gerber, Russell L., Bosch, Walter R., Perez, Carlos A., Purdy, James A.. Quantitative dosimetric verification of an IMRT planning and delivery system. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology, vol.49, no.3, 305-316.
Luo, Wei, Li, Jinsheng, Price Jr., Robert A., Chen, Lili, Yang, Jie, Fan, Jiajin, Chen, Zuoqun, McNeeley, Shawn, Xu, Xiu, Ma, Chang‐Ming. Monte Carlo based IMRT dose verification using MLC log files and R/V outputs. Medical physics, vol.33, no.7, 2557-2564.
Olch, Arthur J.. Dosimetric performance of an enhanced dose range radiographic film for intensity‐modulated radiation therapy quality assurance. Medical physics, vol.29, no.9, 2159-2168.
Siebers, Jeffrey V., Keall, Paul J., Wu, Qiuwen, Williamson, Jeffrey F., Schmidt-Ullrich, Rupert K.. Effect of patient setup errors on simultaneously integrated boost head and neck IMRT treatment plans. International journal of radiation oncology, biology, physics, vol.63, no.2, 422-433.
Stell, Anthony M., Li, Jonathan G., Zeidan, Omar A., Dempsey, James F.. An extensive log‐file analysis of step‐and‐shoot intensity modulated radiation therapy segment delivery errors. Medical physics, vol.31, no.6, 1593-1602.
Woo, M. K., Nico, A.. Impact of multileaf collimator leaf positioning accuracy on intensity modulation radiation therapy quality assurance ion chamber measurements. Medical physics, vol.32, no.5, 1440-1445.
2000 13th Int. Conf. Use of Computers in Radiation Therapy Xia P Chuang C Hguyen-Tan F Fu K K Verhey L J
Zeidan, Omar A, Li, Jonathan G, Ranade, Manisha, Stell, Anthony M, Dempsey, James F. Verification of step-and-shoot IMRT delivery using a fast video-based electronic portal imaging device.. Medical physics, vol.31, no.3, 463-476.
Zhu, X. R., Jursinic, P. A., Grimm, D. F., Lopez, F., Rownd, J. J., Gillin, M. T.. Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator. Medical physics, vol.29, no.8, 1687-1692.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.