최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Medical physics, v.35 no.11, 2008년, pp.5179 - 5186
Alfonso, R. , Andreo, P. , Capote, R. , Huq, M. Saiful , Kilby, W. , Kjäll, P. , Mackie, T. R. , Palmans, H. , Rosser, K. , Seuntjens, J. , Ullrich, W. , Vatnitsky, S.
The use of small fields in radiotherapy techniques has increased substantially, in particular in stereotactic treatments and large uniform or nonuniform fields that are composed of small fields such as for intensity modulated radiation therapy (IMRT). This has been facilitated by the increased avail...
Das, Indra J., Ding, George X., Ahnesjö, Anders. Small fields: Nonequilibrium radiation dosimetry. Medical physics, vol.35, no.1, 206-215.
Sanchez-Doblado, F., Hartmann, G.H., Pena, J., Rosello, J.V., Russiello, G., Gonzalez-Castano, D.M.. A new method for output factor determination in MLC shaped narrow beams. Physica medica : European journal of medical physics, vol.23, no.2, 58-66.
Absorbed dose determination in external beam radiotherapy Andreo P. 2000
Almond, Peter R., Biggs, Peter J., Coursey, B. M., Hanson, W. F., Huq, M. Saiful, Nath, Ravinder, Rogers, D. W. O.. AAPM's TG‐51 protocol for clinical reference dosimetry of high‐energy photon and electron beams. Medical physics, vol.26, no.9, 1847-1870.
Francescon, Paolo, Cora, Stefania, Cavedon, Carlo, Scalchi, Paolo, Reccanello, Sonia, Colombo, Federico. Use of a new type of radiochromic film, a new parallel-plate micro-chamber, MOSFETs, and TLD 800 microcubes in the dosimetry of small beams. Medical physics, vol.25, no.4, 503-511.
Bouchard, Hugo, Seuntjens, Jan. Ionization chamber‐based reference dosimetry of intensity modulated radiation beams. Medical physics, vol.31, no.9, 2454-2465.
Capote, Roberto, Sánchez‐Doblado, Francisco, Leal, Antonio, Lagares, Juan Ignacio, Arráns, Rafael, Hartmann, Günther H.. An EGSnrc Monte Carlo study of the microionization chamber for reference dosimetry of narrow irregular IMRT beamlets. Medical physics, vol.31, no.9, 2416-2422.
Jeraj, Robert, Mackie, Thomas R., Balog, John, Olivera, Gustavo. Dose calibration of nonconventional treatment systems applied to helical tomotherapy : Dose calibration of non-conventional treatment systems. Medical physics, vol.32, no.2, 570-577.
Thomas, S. D., Mackenzie, M., Rogers, D. W. O., Fallone, B. G.. A Monte Carlo derived TG‐51 equivalent calibration for helical tomotherapy. Medical physics, vol.32, no.5, 1346-1353.
Duane, S, Nicholas, D, Palmans, H, Schaeken, B, Sephton, J, Sharpe, P, Thomas, R, Tomsej, M, Tournel, K, Verellen, D, Vynckier, S. SU‐FF‐T‐195: Dosimetry Audit for Tomotherapy Using Alanine/EPR. Medical physics, vol.33, no.6, 2093-2094.
Sharpe, P.H.G., Rajendran, K., Sephton, J.P.. Progress towards an alanine/ESR therapy level reference dosimetry service at NPL. Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry, and medicine, vol.47, no.11, 1171-1175.
Br. J. Radiol. Suppl. 1996 25 Central axis depth dose data for use in radiotherapy
Sharma, Subhash C., Ott, Joseph T., Williams, Jamone B., Dickow, Danny. Commissioning and acceptance testing of a CyberKnife linear accelerator. Journal of applied clinical medical physics, vol.8, no.3, 119-125.
Robotic Radiosurgery Francescon P. 71 2005
Araki, Fujio. Monte Carlo study of a Cyberknife stereotactic radiosurgery system.. Medical physics, vol.33, no.8, 2955-2963.
Francescon, Paolo, Cora, Stefania, Cavedon, Carlo. Total scatter factors of small beams: A multidetector and Monte Carlo study : Total scatter factors of small beams. Medical physics, vol.35, no.2, 504-513.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
출판사/학술단체 등이 한시적으로 특별한 프로모션 또는 일정기간 경과 후 접근을 허용하여, 출판사/학술단체 등의 사이트에서 이용 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.