NTIS 바로가기Journal of neural engineering, v.6 no.6, 2009년, pp.065005 -
Stieglitz, Thomas
Microsystems engineering offers the tools to develop highly sophisticated miniaturized implants to interface with the nervous system. One challenging application field is the development of neural prostheses to restore vision in persons that have become blind by photoreceptor degeneration due to ret...
Akin, T., Najafi, K., Smoke, R.H., Bradley, R.M.. A micromachined silicon sieve electrode for nerve regeneration applications. IEEE transactions on bio-medical engineering, vol.41, no.4, 305-313.
Alteheld, N, Roessler, G, Vobig, M, Walter, P. The Retina Implant New Approach to a Visual Prosthesis / Das Retina-Implant Ein neuer Ansatz für eine Sehprothese. Biomedizinische Technik. Biomedical engineering, vol.49, no.4, 99-103.
Brummer, S. B., Turner, M. J.. Electrochemical Considerations for Safe Electrical Stimulation of the Nervous System with Platinum Electrodes. IEEE transactions on bio-medical engineering, vol.bme24, no.1, 59-63.
Chow, Alan Y, Chow, Vincent Y, Packo, Kirk H, Pollack, John S, Peyman, Gholam A, Schuchard, Ronald. The artificial silicon retina microchip for the treatment of vision loss from retinitis pigmentosa.. Archives of ophthalmology, vol.122, no.4, 460-469.
Cogan, Stuart F., Ehrlich, Julia, Plante, Timothy D., Smirnov, Anton, Shire, Douglas B., Gingerich, Marcus, Rizzo, Joseph F.. Sputtered iridium oxide films for neural stimulation electrodes. Journal of biomedical materials research. Part B, Applied biomaterials, vol.b89, no.2, 353-361.
Donaldson, N. de N., Donaldson, P. E. K.. Performance of platinum stimulating electrodes mapped on the limitvoltage plane : Part 2 Corrsionin vitro. Medical & biological engineering & computing, vol.24, no.4, 431-438.
1997 10.1159/000268026 29 281 0030-3747 Ophthalmic Res. Eckmiller R
2003 43 4486 0146-0404 Invest. Ophthalmol. Vis. Sci Eysel U T
1929 39 435 0368-3877 J. Psychol. Neurol. Foerster O
Haggerty, Holly Susan, Lusted, Hugh S.. Histological Reaction to Polyimide Films in the Cochlea. Acta oto-laryngologica, vol.107, no.1, 13-22.
2007 4 1741-2552 J. Neural Eng. Hessburg P C
2005 10.1088/1741-2560/2/1/014 2 S139 1741-2552 J. Neural Eng. Hornig R
1999 40 143 0146-0404 Invest. Ophthalmol. Vis. Sci. Humayun M S
Humayun, Mark S., Weiland, James D., Fujii, Gildo Y., Greenberg, Robert, Williamson, Richard, Little, Jim, Mech, Brian, Cimmarusti, Valerie, Van Boemel, Gretchen, Dagnelie, Gislin, de Juan Jr., Eugene. Visual perception in a blind subject with a chronic microelectronic retinal prosthesis. Vision research, vol.43, no.24, 2573-2581.
1997 ISO 10993-1
2006 10.47102/annals-acadmedsg.V35N3p137 35 137 Ann. Acad. Med. Singapore Javaheri M
Kerdraon, Yves A, Downie, John A, Suaning, GreggJ, Capon, MalcolmR, Coroneo, MinasT, Lovell, NigelH. Development and surgical implantation of a vision prosthesis modelinto the ovine eye. Clinical & experimental ophthalmology, vol.30, no.1, 36-40.
2009 0146-0404 Invest. Ophthalmol. Vis. Sci. Kim E T
Margalit, Eyal, Maia, Mauricio, Weiland, James D, Greenberg, Robert J, Fujii, Gildo Y, Torres, Gustavo, Piyathaisere, Duke V, O'Hearn, Thomas M, Liu, Wentai, Lazzi, Gianluca, Dagnelie, Gislin, Scribner, Dean A, de Juan Jr, Eugene, Humayun Jr, Mark S. Retinal Prosthesis for the Blind. Survey of ophthalmology, vol.47, no.4, 335-356.
Meyer, Jörg-Uwe. Retina implant—a bioMEMS challenge. Sensors and actuators. A, Physical, vol.97, 1-9.
Meyer, J.-U., Stieglitz, T., Scholz, O., Haberer, W., Beutel, H.. High density interconnects and flexible hybrid assemblies for active biomedical implants. IEEE transactions on advanced packaging : a publication of the IEEE Components, Packaging, and Manufacturing Technology Society and the Lasers and Electro Optics Society, vol.24, no.3, 366-374.
1997 8 14 1048-6690 Med. Device Technol. Noordegraaf J
Richardson, R.R., Miller, J.A., Reichert, W.M.. Polyimides as biomaterials: preliminary biocompatibility testing. Biomaterials, vol.14, no.8, 627-635.
Sakaguchi, Hirokazu, Fujikado, Takashi, Fang, Xiaoyun, Kanda, Hiroyuki, Osanai, Makoto, Nakauchi, Kazuaki, Ikuno, Yasushi, Kamei, Motohiro, Yagi, Tohru, Nishimura, Shigeru, Ohji, Masahito, Yagi, Tetsuya, Tano, Yasuo. Transretinal Electrical Stimulation with a Suprachoroidal Multichannel Electrode in Rabbit Eyes. Japanese journal of ophthalmology, vol.48, no.3, 256-261.
1997 10.1001/archopht.1997.01100150513011 115 511 Arch. Ophthalmol. Santos A
Schanze, Thomas, Hesse, Lutz, Lau, Carsten, Greve, Nina, Haberer, Werner, Kammer, Sascha, Doerge, Thomas, Rentzos, Andreas, Stieglitz, Thomas. An Optically Powered Single-Channel Stimulation Implant as Test System for Chronic Biocompatibility and Biostability of Miniaturized Retinal Vision Prostheses. IEEE transactions on bio-medical engineering, vol.54, no.6, 983-992.
Stensaas, Suzanne S., Stensaas, L. J.. Histopathological evaluation of materials implanted in the cerebral cortex. Acta neuropathologica, vol.41, no.2, 145-155.
1997 2307 Proc. 19th Ann. Int. Conf. of the IEEE Engineering in Medicine and Biology Society Stieglitz T Beutel H Keller R Blau C Meyer JU
Stieglitz, Thomas, Beutel, Hansjo¨rg, Schuettler,, Martin, Meyer, J.-Uwe. Micromachined, Polyimide-Based Devices for Flexible Neural Interfaces. Biomedical microdevices, vol.2, no.4, 283-294.
2000 467 Proc. MICRO.tec 2000 Stieglitz T Keller R Beutel H Meyer J U
1999 37 Suppl. 2 1102-3 Med. Biol. Eng. Com. Stieglitz T
2009 Stieglitz T Wien S Reininger-Mack A Schuettler M Doerge T Robitzki A
1992 10.1001/archopht.1992.01080230134038 110 I634 Arch. Ophthalmol. Stone J L
Veraart, Claude, Duret, Florence, Brelén, Marten, Oozeer, Medhy, Delbeke, Jean. Vision rehabilitation in the case of blindness. Expert review of medical devices, vol.1, no.1, 139-153.
Walter, Peter, Kisva´rday, Zolta´n F., Go¨rtz, Michael, Alteheld, Nils, Rossler, Gernot, Stieglitz, Thomas, Eysel, Ulf T.. Cortical Activation Via an Implanted Wireless Retinal Prosthesis. Investigative ophthalmology & visual science, vol.46, no.5, 1780-.
1998 39 S990 0146-0404 Invest. Ophthalmol. Vis. Sci. Walter P
WALTER, PETER, SZURMAN, PETER, VOBIG, MICHAEL, BERK, HÜSNÜ, LÜDTKE-HANDJERY, HANS-CHRISTIAN, RICHTER, HORST, MITTERMAYER, CHRISTIAN, HEIMANN, KLAUS, SELLHAUS, BERND. SUCCESSFUL LONG-TERM IMPLANTATION OF ELECTRICALLY INACTIVE EPIRETINAL MICROELECTRODE ARRAYS IN RABBITS. Retina, vol.19, no.6, 546-546.
Williams, D.F.. On the mechanisms of biocompatibility. Biomaterials, vol.29, no.20, 2941-2953.
WILMS, MARCUS, EGER, MARCUS, SCHANZE, THOMAS, ECKHORN[dagger], REINHARD. Visual resolution with epi-retinal electrical stimulation estimated from activation profiles in cat visual cortex. Visual neuroscience, vol.20, no.5, 543-555.
Wong, Y.T., Chen, S.C., Seo, J.M., Morley, J.W., Lovell, N.H., Suaning, G.J.. Focal activation of the feline retina via a suprachoroidal electrode array. Vision research, vol.49, no.8, 825-833.
2005 10.1088/1741-2560/2/1/007 2 S48 1741-2560 J. Neural Eng. Yamauchi Y
Zrenner, E., Stett, A., Weiss, S., Aramant, R.B., Guenther, E., Kohler, K., Miliczek, K.-D., Seiler, M.J., Haemmerle, H.. Can subretinal microphotodiodes successfully replace degenerated photoreceptors?. Vision research, vol.39, no.15, 2555-2567.