NTIS 바로가기Medical physics, v.35 no.2, 2008년, pp.480 - 486
Song, William Y. , Kamath, Srijit , Ozawa, Shuichi , Al Ani, Shlomi , Chvetsov, Alexei , Bhandare, Niranjan , Palta, Jatinder R. , Liu, Chihray , Li, Jonathan G.
The purpose of this study is to establish a comprehensive set of dose measurements data obtained from the X-ray Volumetric Imager (XVI, Elekta Oncology Systems) and the On-Board Imager (OBI, Varian Medical Systems) cone-beam CT (CBCT) systems. To this end, two uniform-density cylindrical acrylic pha...
Jaffray Flat-panel cone-beam computed tomography for image-guided radiation therapy Int. J. Radiat. Oncol. Biol. Phys. 53 1337 2002 10.1016/S0360-3016(02)02884-5
Jaffray Emergent technologies for 3-dimensional image-guided radiation delivery Semin. Radiat. Oncol. 15 208 2005 10.1016/j.semradonc.2005.01.003
Amies A multi-platform approach to image guided radiation therapy (IGRT) Med. Dosim. 31 12 2006 10.1016/j.meddos.2005.12.013
Yoo A quality assurance program for the on-board imager Med. Phys. 10.1118/1.2362872 33 4431 2006
Oldham Cone-beam-CT guided radiation therapy: A model for on-line application Radiother. Oncol. 10.1016/j.radonc.2005.03.026 75 271 2005
Thilmann Correction of patient positioning errors based on in-line cone beam CTs: Clinical implementation and first experiences Radiat. Oncol. 1 16 2006 10.1186/1748-717X-1-16
Ding Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapy Phys. Med. Biol. 10.1088/0031-9155/52/6/004 52 1595 2007
Mackie Image guidance for precise conformal radiotherapy Int. J. Radiat. Oncol. Biol. Phys. 56 89 2003 10.1016/S0360-3016(03)00090-7
Song Image-guided adaptive radiation therapy (IGART): Radiobiological and dose escalation considerations for localized carcinoma of the prostate Med. Phys. 10.1118/1.1935775 32 2193 2005
Song Dosimetric evaluation of daily rigid and non-rigid geometric correction strategies during on-line image-guided radiation therapy (IGRT) of prostate cancer Med. Phys. 10.1118/1.2405325 34 352 2007
Martinez Improvement in dose escalation using the process of adaptive radiotherapy combined with three-dimensional conformal or intensity-modulated beams for prostate cancer Int. J. Radiat. Oncol. Biol. Phys. 50 1226 2001 10.1016/S0360-3016(01)01552-8
De Crevoisier Increased risk of biochemical and local failure in patients with distended rectum on the planning CT for prostate cancer radiotherapy Int. J. Radiat. Oncol. Biol. Phys. 62 965 2005 10.1016/j.ijrobp.2004.11.032
Ghilezan Online image-guided intensity-modulated radiotherapy for prostate cancer: How much improvement can we expect? A theoretical assessment of clinical benefits and potential dose escalation by improving precision and accuracy of radiation delivery Int. J. Radiat. Oncol. Biol. Phys. 60 1602 2004 10.1016/j.ijrobp.2004.07.709
Schaly Dosimetric impact of image-guided 3D conformal radiation therapy of prostate cancer Phys. Med. Biol. 10.1088/0031-9155/50/13/008 50 3083 2005
Happersett A study of the effects of internal organ motion on dose distribution in conformal prostate treatments Radiother. Oncol. 10.1016/S0167-8140(03)00039-2 66 263 2003
Islam Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapy Med. Phys. 10.1118/1.2198169 33 1573 2006
Wen Dose delivered from Varian's CBCT to patients receiving IMRT for prostate cancer Phys. Med. Biol. 10.1088/0031-9155/52/8/015 52 2267 2007
Murphy The management of imaging dose during image-guided radiotherapy: Report of the AAPM Task Group 75 Med. Phys. 10.1118/1.2775667 34 4041 2007
Zelefsky High-dose intensity modulated radiation therapy for prostate cancer: early toxicity and biochemical outcome in 772 patients Int. J. Radiat. Oncol. Biol. Phys. 53 1111 2002 10.1016/S0360-3016(02)02857-2
Zelefsky Clinical experience with intensity modulated radiation therapy (IMRT) in prostate cancer Radiother. Oncol. 10.1016/S0167-8140(99)00100-0 55 241 2000
Ma AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology Med. Phys. 10.1118/1.1374247 28 868 2001
Cho Cone-beam CT for radiotherapy applications Phys. Med. Biol. 10.1088/0031-9155/40/11/007 40 1863 1995
Graham Compensators for dose and scatter management in cone-beam computed tomography Med. Phys. 10.1118/1.2740466 34 2691 2007
P. J. P. Lin et al. 1993 www.aapm.org
Shope A method for describing the doses delivered by transmission x-ray computed tomography Med. Phys. 10.1118/1.594995 8 488 1991
McNitt-Gray AAPM/RSNA physics tutorial for residents: Topics in CT. Radiation dose in CT Radiographics 22 1541 2002 10.1148/rg.226025128
Dixon A new look at CT dose measurement: Beyond CTDI Med. Phys. 10.1118/1.1576952 30 1272 2003
Brenner Is it time to retire the CTDI for CT quality assurance and dose optimization? Med. Phys. 10.1118/1.2040747 32 3225 2005
Fahrig Dose and image quality for a cone-beam C-arm CT system Med. Phys. 10.1118/1.2370508 33 4541 2006
Nickoloff Influence of phantom diameter, kVp and scan mode upon computed tomography dose index Med. Phys. 10.1118/1.1543149 30 395 2003
Hill The variation in biological effectiveness of x-rays and gamma rays with energy Radiat. Prot. Dosimetry 112 471 2004 10.1093/rpd/nch091
Yoo Dosimetric feasibility of cone-beam CT-based treatment planning compared to CT-based treatment planning Int. J. Radiat. Oncol. Biol. Phys. 66 1553 2006 10.1016/j.ijrobp.2006.08.031
Yang Evaluation of on-board kV cone beam CT (CBCT)-based dose calculation Phys. Med. Biol. 10.1088/0031-9155/52/3/011 52 685 2007