NTIS 바로가기Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of, v.12 no.6, 2010년, pp.811 - 816
Murgatroyd, Francis D. (Kings College Hospital, Cardiac Catheter Suite, Level 1 , Denmark Hill, SE5 9RS London , UK) , Helmling, Erhard (Westpfalzklinikum GmbH , Hellmut-Hartert Straße 1, 67655 Kaiserslautern , Germany) , Lemke, Bernd (Klinikum Lü) , Eber, Bernd (denscheid , Paulmannshö) , Mewis, Christian (her Straße 14, 58515 Lü) , van der Meer-Hensgens, Judith (denscheid , Germany) , Chang, Yanping (Klinikum Kreuzschwestern Wels , Grieskirchner Straße 42, 4600 Wels , Austria) , Khalameizer, Vladimir (Medical Clinic of University Saarland , Kirrberger Straße, 66424 Homburg) , Katz, Amos (Medtronic, Bakken Research Center , Endepolsdomein 5, 6229GW Maastricht , The Netherlands)
AimsThe Secura™ ICD and Consulta™ CRT-D are the first defibrillators to have automatic right atrial (RA), right ventricular (RV), and left ventricular (LV) capture management (CM). Complete CM was evaluated in an implantable cardioverter defibrillator (ICD) population.Methods and resultsTwo prospect...
1 Crossley GH Mead H Kleckner K Sheldon T Davenport L Harsch MR Automated left ventricular capture management Pacing Clin Electrophysiol 2007 30 1190 200 17897121
2 Silvetti MS De Santis A Grutter G Di Ciommo V Drago F Ventricular capture management in pediatric pacing: efficacy and safety Ital Heart J 2005 6 751 6 16212078
3 Suri R Harthorne JW Galvin J Automatically optimizing pacing output: an excellent idea, but with potentially lethal pitfalls Pacing Clin Electrophysiol 2001 24 520 3 11341095
4 Cohen MI Buck K Tanel RE Vetter VL Rhodes LA Cox J Capture management efficacy in children and young adults with endocardial and unipolar epicardial systems Europace 2004 6 248 55 15121079
5 Sperzel J Siemon G Presser HJ Klimek W Bub E Roesenfeld M Benefits of enhanced ventricular capture management in automated pacemakers Europace 2003 4 Suppl. B abstr. A26: B40
6 Sperzel J Milasinovic G Smith TW Mead H Brandt J Haisty WK Automatic measurement of atrial pacing thresholds in dual-chamber pacemakers: clinical experience with atrial capture management Heart Rhythm 2005 2 1203 10 16253910
7 Silvetti MS De Santis A Grovale N Grutter G Baccarini A Drago F Ventricular pacing threshold variations in the young Pacing Clin Electrophysiol 2007 30 175 81 17338712
8 Gregoratos G Abrams J Epstein AE Freedman RA Hayes DL Hlatky MA ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices—summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines) J Am Coll Cardiol 2002 40 1703 19 12427427
9 Zipes DP Camm AJ Borggrefe M Buxton AE Chaitman B Fromer M ACC/AHA/ESC 2006 guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: a report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Develop Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death) J Am Coll Cardiol 2006 48 e247 e346 16949478
10 Biffi M Spitali G Silvetti MS Argnani S Rubino I Fontana P Atrial threshold variability: implications for automatic atrial stimulation algorithms Pacing Clin Electrophysiol 2007 30 1445 54 18070297
11 Biffi M Bertini M Saporito D Ziacchi M Stabellini S Valsecchi S Automatic management of left ventricular stimulation: hints for technologic improvement Pacing Clin Electrophysiol 2009 32 346 53 19272065
12 Burri H Gerritse B Davenport L Demas M Sticherling C Fluctuation of left ventricular thresholds and required safety margin for left ventricular pacing with cardiac resynchronization therapy Europace 2009 11 931 6 19435738
13 Chen RH Chen KP Wang FZ Hua W Zhang S Impact of automatic threshold capture on pulse generator longevity Chin Med J (Engl) 2006 119 925 9 16780772
14 Boriani G Rusconi L Biffi M Pavia L Sassara M Malfitano D Role of ventricular autocapture function in increasing longevity of DDDR pacemakers: a prospective study Europace 2006 8 216 20 16627443
15 Crossley GH Gayle DD Simmons TW Haisty WK Bailey JR Davis-O'Brien K Reprogramming pacemakers enhances longevity and is cost-effective Circulation 1996 94 II245 7 8901754
16 Biffi M Sperzel J Martignani C Branzi A Boriani G Evolution of pacing for bradycardia: autocapture Eur Heart J 2007 9 I23 I32
17 Brockes C Rahn-Schonbeck M Duru F Candinas R Turina M Impact of automatic adjustment of stimulation outputs on pacemaker longevity in a new dual-chamber pacing system J Interv Card Electrophysiol 2003 8 45 8 12652177
18 Ribeiro AL Rincon LG Oliveira BG Vinha CR Melatto D Torres AA Automatic adjustment of pacing output in the clinical setting Am Heart J 2004 147 127 31 14691430