최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine, v.68 no.2, 2012년, pp.441 - 451
Frost, Robert (Centre for Functional MRI of the Brain, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK) , Porter, David A. (Siemens AG, Healthcare Sector, Erlangen, Germany) , Miller, Karla L. (Centre for Functional MRI of the Brain, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK) , Jezzard, Peter
AbstractSingle‐shot echo‐planar imaging has been used widely in diffusion magnetic resonance imaging due to the difficulties in correcting motion‐induced phase corruption in multishot data. Readout‐segmented EPI has addressed the multishot problem by introducing a two‐d...
1 Johansen‐Berg H , Behrens TEJ . Just pretty pictures? What diffusion tractography can add in clinical neuroscience . Curr Opin Neurol 2006 ; 19 : 379 – 385 .
2 Moseley ME , Kucharczyk J , Mintorovitch J , Cohen Y , Kurhanewicz J , Derugin N , Asgari H , Norman D . Diffusion‐weighted MR imaging of acute stroke: correlation with T 2 ‐weighted and magnetic susceptibility‐enhanced MR imaging in cats . AJNR Am J Neuroradiol 1990 ; 11 : 423 – 429 .
3 Warach S , Chien D , Li W , Ronthal M , Edelman RR . Fast magnetic resonance diffusion‐weighted imaging of acute human stroke . Neurology 1992 ; 42 : 1717 – 1723 .
4 van Everdingen KJ , van der Grond J , Kappelle LJ , Ramos LM , Mali WP . Diffusion‐weighted magnetic resonance imaging in acute stroke . Stroke 1998 ; 29 : 1783 – 1790 .
5 Wu O , Koroshetz WJ , Ostergaard L , Buonanno FS , Copen WA , Gonzalez RG , Rordorf G , Rosen BR , Schwamm LH , Weisskoff RM , Sorensen AG . Predicting tissue outcome in acute human cerebral ischemia using combined diffusion‐ and perfusion‐weighted MR imaging . Stroke 2001 ; 32 : 933 – 942 .
6 Redgrave JNE , Coutts SB , Schulz UG , Briley D , Rothwell PM . Systematic review of associations between the presence of acute ischemic lesions on diffusion‐weighted imaging and clinical predictors of early stroke risk after transient ischemic attack . Stroke 2007 ; 38 : 1482 – 1488 .
7 Yagci AB , Ozari N , Aybek Z , Duzcan E . The value of diffusion‐weighted MRI for prostate cancer detection and localization . Diagn Interv Radiol 2011 ; 17 : 130 – 134 .
8 Robson MD , Anderson AW , Gore JC . Diffusion‐weighted multiple shot echo planar imaging of humans without navigation . Magn Reson Med 1997 ; 38 : 82 – 88 .
9 Porter DA , Heidemann RM . High resolution diffusion‐weighted imaging using readout‐segmented echo‐planar imaging, parallel imaging and a two‐dimensional navigator‐based reacquisition . Magn Reson Med 2009 ; 62 : 468 – 475 .
10 Griswold MA , Jakob PM , Heidemann RM , Nittka M , Jellus V , Wang J , Kiefer B , Haase A . Generalized autocalibrating partially parallel acquisitions (GRAPPA) . Magn Reson Med 2002 ; 47 : 1202 – 1210 .
11 Miller KL , Pauly JM . Nonlinear phase correction for navigated diffusion imaging . Magn Reson Med 2003 ; 50 : 343 – 353 .
12 Nguyen Q , Clemence M , Ordidge RJ . The Use of Intelligent Re‐acquisition to Reduce Scan Time in MRI Degraded by Motion. In: Proceedings of the 6th Annual Meeting of ISMRM, Sydney, Australia, 1998 (abstract 134).
13 Holdsworth SJ , Skare S , Newbould RD , Bammer R . Robust GRAPPA‐accelerated diffusion‐weighted readout‐segmented (RS)‐EPI . Magn Reson Med 2009 ; 62 : 1629 – 1640 .
14 Heidemann RM , Porter DA , Anwander A , Feiweier T , Heberlein K , Knosche TR , Turner R . Diffusion imaging in humans at 7T using readout‐segmented EPI and GRAPPA . Magn Reson Med 2010 ; 64 : 9 – 14 .
15 Frost R , Porter DA , Feiweier T , Jezzard P . Homodyne Reconstruction of Partial Fourier Readout‐Segmented EPI for Diffusion Imaging. In: Proceedings of the 18th Annual Meeting of ISMRM, Stockholm, Sweden, 2010 (abstract 1625).
16 Holdsworth SJ , Skare S , Bammer R . On the application of phase correction and use of k‐space entropy in partial Fourier diffusion‐weighted EPI. In: Proceedings of the 17th Annual Meeting of ISMRM, Honolulu, Hawii, USA, 2009 (abstract 4617).
17 Holdsworth SJ , Skare S , Aksoy M , O'Halloran RL , Bammer R . Comparison of two alternative approaches for diffusion‐weighted Readout‐Segmented (RS)‐EPI. In: Proceedings of the 19th Annual Meeting of ISMRM, Montreal, Canada, 2011 (abstract 3932).
18 Noll DC , Nishimura DG , Macovski A . Homodyne detection in magnetic resonance imaging . IEEE Trans Med Imaging 1991 ; 10 : 154 – 163 .
19 Haacke EM , Lindskog ED , Lin W . A fast, iterative, partial‐Fourier technique capable of local phase recovery . J Magn Reson 1991 ; 92 : 126 – 145 .
20 Morelli JN , Runge VM , Feiweier T , Kirsch JE , Williams KW , Attenberger UI . Evaluation of a modified Stejskal‐Tanner diffusion encoding scheme, permitting a marked reduction in TE, in diffusion‐weighted imaging of stroke patients at 3 T . Invest Radiol 2010 ; 45 : 29 – 35 .
21 Smith SM , Johansen‐Berg H , Jenkinson M , Rueckert D , Nichols TE , Miller KL , Robson MD , Jones DK , Klein JC , Bartsch AJ , Behrens TEJ . Acquisition and voxelwise analysis of multi‐subject diffusion data with tract‐based spatial statistics . Nat Protoc 2007 ; 2 : 499 – 503 .
22 Jones DK . The effect of gradient sampling schemes on measures derived from diffusion tensor MRI: a Monte Carlo study . Magn Reson Med 2004 ; 51 : 807 – 815 .
23 Jones DK , Horsfield MA , Simmons A . Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging . Magn Reson Med 1999 ; 42 : 515 – 525 .
24 McGibney G , Smith MR , Nichols ST , Crawley A . Quantitative evaluation of several partial Fourier reconstruction algorithms used in MRI . Magn Reson Med 1993 ; 30 : 51 – 59 .
25 Behrens TEJ , Woolrich MW , Jenkinson M , Johansen‐Berg H , Nunes RG , Clare S , Matthews PM , Brady JM , Smith SM . Characterization and propagation of uncertainty in diffusion‐weighted MR imaging . Magn Reson Med 2003 ; 50 : 1077 – 1088 .
26 Smith SM . Fast robust automated brain extraction . Hum Brain Mapp 2002 ; 17 : 143 – 155 .
27 Behrens TEJ , Berg HJ , Jbabdi S , Rushworth MFS , Woolrich MW . Probabilistic diffusion tractography with multiple fibre orientations: what can we gain? Neuroimage 2007 ; 34 : 144 – 155 .
28 Zhang Y , Brady M , Smith S . Segmentation of brain MR images through a hidden Markov random field model and the expectation‐maximization algorithm . IEEE Trans Med Imaging 2001 ; 20 : 45 – 57 .
29 Bammer R , Augustin M , Strasser‐Fuchs S , Seifert T , Kapeller P , Stollberger R , Ebner F , Hartung HP , Fazekas F . Magnetic resonance diffusion tensor imaging for characterizing diffuse and focal white matter abnormalities in multiple sclerosis . Magn Reson Med 2000 ; 44 : 583 – 591 .
30 Ciccarelli O , Werring DJ , Wheeler‐Kingshott CA , Barker GJ , Parker GJ , Thompson AJ , Miller DH . Investigation of MS normal‐appearing brain using diffusion tensor MRI with clinical correlations . Neurology 2001 ; 56 : 926 – 933 .
31 Heiervang E , Behrens TEJ , Mackay CE , Robson MD , Johansen‐Berg H . Between session reproducibility and between subject variability of diffusion MR and tractography measures . NeuroImage 2006 ; 33 : 867 – 877 .
32 Smith SM , Jenkinson M , Johansen‐Berg H , Rueckert D , Nichols TE , Mackay CE , Watkins KE , Ciccarelli O , Cader MZ , Matthews PM , Behrens TEJ . Tract‐based spatial statistics: voxelwise analysis of multi‐subject diffusion data . Neuroimage 2006 ; 31 : 1487 – 1505 .
33 Jones DK . Determining and visualizing uncertainty in estimates of fiber orientation from diffusion tensor MRI . Magn Reson Med 2003 ; 49 : 7 – 12 .
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
출판사/학술단체 등이 한시적으로 특별한 프로모션 또는 일정기간 경과 후 접근을 허용하여, 출판사/학술단체 등의 사이트에서 이용 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.