최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기The British journal of radiology, v.86 no.1028, 2013년, pp.20130002 - 20130002
Zhang, G (Department of Radiology, University Hospitals Leuven, Leuven, Belgium) , Marshall, N (Department of Radiology, University Hospitals Leuven, Leuven, Belgium) , Jacobs, R (Oral Imaging Center, University Hospitals Leuven, Leuven, Belgium) , Liu, Q (Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, China) , Bosmans, H (Department of Radiology, University Hospitals Leuven, Leuven, Belgium)
Objective:To investigate the influence of bowtie filtration on dedicated cone beam CT (CBCT) of the head and neck.Methods:A validated hybrid simulation technique was used to model a commercial CBCT system with offset scanning geometry, 90 kV tube potential and 145×75 mm imaging field of view....
Graham, S. A., Moseley, D. J., Siewerdsen, J. H., Jaffray, D. A.. Compensators for dose and scatter management in cone‐beam computed tomography. Medical physics, vol.34, no.7, 2691-2703.
Ding, George X, Duggan, Dennis M, Coffey, Charles W. Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapy. Physics in medicine & biology, vol.52, no.6, 1595-1615.
Mail, N., Moseley, D. J., Siewerdsen, J. H., Jaffray, D. A.. The influence of bowtie filtration on cone‐beam CT image quality. Medical physics, vol.36, no.1, 22-32.
Boone, John M.. Method for evaluating bow tie filter angle‐dependent attenuation in CT: Theory and simulation results. Medical physics, vol.37, no.1, 40-48.
Handbook of medical imaging: physics and psychophysics Beutel J 1 2000
Bootsma, G. J., Verhaegen, F., Jaffray, D. A.. The effects of compensator and imaging geometry on the distribution of x‐ray scatter in CBCT. Medical physics, vol.38, no.2, 897-914.
Miracle, A.C., Mukherji, S.K.. Conebeam CT of the Head and Neck, Part 1: Physical Principles. AJNR, American journal of neuroradiology, vol.30, no.6, 1088-1095.
Zhang, G, Pauwels, R, Marshall, N, Shaheen, E, Nuyts, J, Jacobs, R, Bosmans, H. Development and validation of a hybrid simulation technique for cone beam CT: application to an oral imaging system. Physics in medicine & biology, vol.56, no.18, 5823-5843.
Wang, Ge. X‐ray micro‐CT with a displaced detector array. Medical physics, vol.29, no.7, 1634-1636.
BEAMnrc users manual. NRCC Report PIRS-0509(A)revK. Rogers DWO 2009
NRCC Report PIRS-701 Kawrakow I 2010
IEEE Nucl Sci Symp Conf Rec Wunderlich A 4379 6 2007
Zubal, I. George, Harrell, Charles R., Smith, Eileen O., Rattner, Zachary, Gindi, Gene, Hoffer, Paul B.. Computerized three‐dimensional segmented human anatomy. Medical physics, vol.21, no.2, 299-302.
Ann ICRP International Commission on Radiological Protection 1 32 2002
Schulze, R, Heil, U, Groβ, D, Bruellmann, DD, Dranischnikow, E, Schwanecke, U, Schoemer, E. Artefacts in CBCT: a review. Dento maxillo facial radiology, vol.40, no.5, 265-273.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
저자가 공개 리포지터리에 출판본, post-print, 또는 pre-print를 셀프 아카이빙 하여 자유로운 이용이 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.