NTIS 바로가기Biomedical engineering online, v.12, 2013년, pp.82 - 82
Chauhan, Munish (Department of Biomedical Engineering, Kyung Hee University, Yongin, Korea) , Jeong, Woo Chul (Department of Biomedical Engineering, Kyung Hee University, Yongin, Korea) , Kim, Hyung Joong (Department of Biomedical Engineering, Kyung Hee University, Yongin, Korea) , Kwon, Oh In (Department of Mathematics, Konkuk University, Seoul, Korea) , Woo, Eung Je (Department of Biomedical Engineering, Kyung Hee University, Yongin, Korea)
BackgroundMagnetic resonance electrical impedance tomography (MREIT) has been introduced as a non-invasive method for visualizing the internal conductivity and/or current density of an electrically conductive object by externally injected currents. The injected current through a pair of surface elec...
Joy MLG Scott GC Henkelman RM In vivo detection of applied electric currents by magnetic resonance imaging Magn Reson Imag 1989 7 89 94 10.1016/0730-725X(89)90328-7
Scott GC Joy MLG Armstrong RL Henkelman RM Measurement of nonuniform current density by magnetic resonance IEEE Trans Med Imag 1991 10 362 374 10.1109/42.97586
Ider YZ Birgul O Use of the magnetic field generated by the internal distribution of injected currents for Electrical Impedance Tomography (MR-EIT) Elektrik 1998 6 215 225
Eyuboglu M Birgul O IY Z A dual modality system for high resolution-true conductivity imaging Proc. XI Int. Conf. Electrical Bioimpedance (ICEBI) 2001 409 413
Birgul O Eyuboglu BM Ider YZ Current constrained voltage scaled reconstruction (CCVSR) algorithm for MR-EIT and its performance with different probing current patterns Phys Med Biol 2003 48 653 671 10.1088/0031-9155/48/5/307 12696801
Kwon O Woo EJ Yoon JR Seo JK Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm IEEE Trans Biomed Eng 2002 48 160 167 12066883
Kim YJ Kwon O Seo JK Woo EJ Uniqueness and convergence of conductivity image reconstruction in magnetic resonance electrical impedance tomography Inverse Probl 2003 19 1213 1225 10.1088/0266-5611/19/5/312
Ider YZ Onart S Lionheart WRB Uniqueness and reconstruction in magnetic resonance-electrical impedance tomography(MR-EIT) Physiol Meas 2003 24 591 604 10.1088/0967-3334/24/2/368 12812441
Muftuler L Hamamura M Birgul O Nalcioglu O Resolution and contrast in magnetic resonance electrical impedance tomography (MREIT) and its application to cancer imaging Tech Cancer Res Treat 2004 3 599 609
Ozdemir M Eyuboglu BM Ozbek O Equipotential projection-based magnetic resonance electrical impedance tomography and experimental realization Phys Med Biol 2004 49 4765 4783 10.1088/0031-9155/49/20/008 15566174
Seo JK Yoon JR Woo EJ Kwon O Reconstruction of conductivity and current density images using only one component of magnetic field measurements IEEE Trans Biomed Eng 2003 50 1121 1124 10.1109/TBME.2003.816080 12943280
Oh SH Lee BI Woo EJ Lee SY Cho MH Kwon O Seo JK Conductivity and current density image reconstruction using harmonic Bz algorithm in magnetic resonance electrical impedance tomography Phys Med Biol 2003 48 3101 3116 10.1088/0031-9155/48/19/001 14579854
Park C Kwon O Woo EJ Seo JK Electrical conductivity imaging using gradient Bz decomposition algorithm in magnetic resonance electrical impedance tomography (MREIT) IEEE Trans Med Imag 2004 23 388 394 10.1109/TMI.2004.824228
Joy MLG MR current density and conductivity imaging: the state of the art Proc. 26th Ann. Int. Conf. IEEE EMBS 2004 San Francisco 5315 5319
Lee BI Lee SH Kim TS Kwon O Woo EJ Seo JK Harmonic decomposition in PDE-based denoising technique for magnetic resonance electrical impedance tomography IEEE Trans Biomed Eng 2005 52 1912 1920 10.1109/TBME.2005.856258 16285395
Oh SH Lee BI Woo EJ Lee SY Kim TS Kwon O Seo JK Electrical conductivity images of biological tissue phantoms in MREIT Physiol Meas 2005 26 S279 S288 10.1088/0967-3334/26/2/026 15798241
Gao N Zhu SA He BA New magnetic resonance electrical impedance tomography (MREIT) algorithm: the RSM-MREIT algorithm with applications to estimation of human head conductivity Phys Med Biol 2006 51 3067 3083 10.1088/0031-9155/51/12/005 16757863
Birgul O Hamamura M Muftuler L Nalcioglu O Contrast and spatial resolution in MREIT using low amplitude current Phys Med Biol 2006 51 5035 5049 10.1088/0031-9155/51/19/020 16985286
Kim HJ Oh TI Kim YT Lee BI Woo EJ Seo JK Lee SY Kwon O Park C Kang BT Park HM In vivo electrical conductivity imaging of a canine brain using a 3 T MREIT system Physiol Meas 2008 29 1145 1155 10.1088/0967-3334/29/10/001 18799838
Kim HJ Kim YT Minhas AS Jeong WC Woo EJ Seo JK Kwon OJ In Vivo high-resolution conductivity imaging of the human leg using MREIT: the first human experiment IEEE Trans Med Imag 2009 99 160 167
Woo EJ Seo JK Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging Physiol Meas 2008 29 R1 R26 10.1088/0967-3334/29/10/R01 18799834
Hamamura M Muftuler L Fast imaging for magnetic resonance electrical impedance tomography Magn Reson Imaging 2008 26 739 745 10.1016/j.mri.2008.01.031 18499381
Muftuler L Chen G Hamamura M Ha SH MREIT with SENSE acceleration using a dedicated RF coil design Physiol Meas 2009 30 913 929 10.1088/0967-3334/30/9/004 19641236
Park HM Nam HS Kwon O Magnetic flux density reconstruction using interleaved partial Fourier acquisitions in MREIT Phys Med Biol 2011 56 2059 2073 10.1088/0031-9155/56/7/010 21386139
Scott GC Joy MLG Armstrong RL Henkelman RM Sensitivity of magnetic resonance current density imaging J Magn Reson 1992 97 235 254
Sadleir R Grant S Zhang SU Lee BI Pyo HC Oh SH Park C Woo EJ Lee SY Kwon O Seo JK Noise analysis in MREIT at 3 and 11 Tesla field strength Physiol Meas 2005 26 875 884 10.1088/0967-3334/26/5/023 16088075
Nam H Kwon O Optimization of multiply acquired magnetic flux density Bz using ICNE-Multiecho train in MREIT Phys Med Biol 2010 55 2743 2759 10.1088/0031-9155/55/9/021 20400810
Park C Lee BI Kwon O Woo EJ Measurement of induced magnetic flux density using injection current nonlinear encoding (ICNE) in MREIT Physiol Meas 2007 28 117 127 10.1088/0967-3334/28/2/001 17237584
Woo EJ Functional brain imaging using MREIT and EIT: Requirements and feasibility 8th Int. Conf. on Bioelectromagnetism 2011 131 134
Sadleir RJ Grant SC Woo EJ Can high-field MREIT be used to directly detect neural activity? Theoretical considerations Neuroimage 2010 52 205 216 10.1016/j.neuroimage.2010.04.005 20382240
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
오픈액세스 학술지에 출판된 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.