NTIS 바로가기PloS one, v.9 no.5, 2014년, pp.e96899 -
Wang, Jinghua (Center for Cognitive and Behavioral Brain Imaging, The Ohio State University, Columbus, Ohio, United States of America) , He, Lili (Center for Perinatal Research, Nationwide Children’s Hospital, Columbus, Ohio, United States of America) , Zheng, Hairong (Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China) , Lu, Zhong-Lin (Center for Cognitive and Behavioral Brain Imaging, The Ohio State University, Columbus, Ohio, United States of America)
The three-dimension (3D) magnetization-prepared rapid gradient-echo (MP-RAGE) sequence is one of the most popular sequences for structural brain imaging in clinical and research settings. The sequence captures high tissue contrast and provides high spatial resolution with whole brain coverage in a s...
1 Mugler JP , Brookeman JR ( 1990 ) Three-dimensional magnetization-prepared rapid gradient-echo imaging (3D MP RAGE). Magn. Reson. Med . 15 : 152 – 157 .
2 Ashburner J , Friston KJ ( 2000 ) Voxel-based morphometry - The methods . Neuroimage 11 : 805 – 821 . 10860804
3 Sastre-Garriga J , Arevalo MJ , Renom M , Alonso J , Gonzalez I , et al ( 2009 ) Brain volumetry counterparts of cognitive impairment in patients with multiple sclerosis. J. Neurol. Sci . 282 : 120 – 124 .
4 Pell GS , Briellmann RS , Pardoe H , Abbott DF , Jackson GD ( 2008 ) Composite voxel-based analysis of volume and T2 relaxometry in temporal lobe epilepsy . Neuroimage 39 : 1151 – 1161 . 18042496
5 Briellmann RS , Pell GS , Wellard RM , Mitchell LA , Abbott DF , et al ( 2003 ) MR imaging of epilepsy: State of the art at 1.5 T and potential of 3 T. Epileptic Disord . 5 : 3 – 20 .
6 Williams LA , DeVito TJ , Winter JD , Orr TN , Thompson RT , et al ( 2007 ) Optimization of 3D MP-RAGE for neonatal brain imaging at 3.0 T. Magn. Reson . Imaging 25 : 1162 – 1170 .
7 Tintore M , Sastre-Garriga J ( 2008 ) New treatment measurements for treatment effects on relapses and progression. J. Neurol. Sci . 274 : 80 – 83 .
8 Bernstein MA, King KF, Zhou XJ (2004) Handbook of MRI Pulse Sequences. Elsevier Academic Press, 1223 p.
9 Epstein FH , Mugler JP , Brookeman JR ( 1994 ) Optimization of Parameter Values for Complex Pulse Sequences by Simulated Annealing - Application to 3d Mp-Rage Imaging of the Brain. Magn. Reson. Med . 31 : 164 – 177 .
10 Deichmann R , Good CD , Josephs O , Ashburner J , Turner R ( 2000 ) Optimization of 3-D MP-RAGE sequences for structural brain imaging . Neuroimage 12 : 112 – 127 . 10875908
11 Tardif CL , Collins DL , Pike GB ( 2010 ) Regional Impact of Field Strength on Voxel-Based Morphometry Results. Hum. Brain Mapp . 31 : 943 – 957 .
12 Wu HH , Nishimura DG ( 2010 ) 3D Magnetization-Prepared Imaging Using a Stack-of-Rings Trajectory. Magn. Reson. Med . 63 : 1210 – 1218 .
13 Lin C , Bernstein MA ( 2008 ) 3D magnetization prepared elliptical centric fast gradient echo Imaging. Magn. Reson. Med . 59 : 434 – 439 .
14 Jack CR , Bernstein MA , Fox NC , Thompson P , Alexander G , et al ( 2008 ) The Alzheimer’s Disease Neuroimaging Initiative (ADNI): MRI methods. J. Magn. Reson . Imaging 27 : 685 – 691 .
15 Tardif CL , Collins DL , Pike GB ( 2009 ) Sensitivity of voxel-based morphometry analysis to choice of imaging protocol at 3 T . Neuroimage 44 : 827 – 838 . 18996205
16 MGH (2009) http://surfer.nmr.mgh.harvard.edu/fswiki/FreeSurferWiki?action=AttachFile&do=get&target=FreeSurfer_Suggested_Morphometry_Protocols.pdf (Accessed 2014 March 28).
17 Nkongchu K , Santyr G ( 2005 ) An improved 3-D Look–Locker imaging method for T(1) parameter estimation. Magn. Reson . Imaging 23 : 801 – 807 .
18 Gowland PA , Leach MO ( 1992 ) Fast and accurate measurements of T1 using a multi-readout single inversion recovery sequence. Magn. Reson. Med . 26 : 79 – 88 .
19 Marques JP , Kober T , Krueger G , van der Zwaag W , Van de Moortele PF , et al ( 2010 ) MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high field . Neuroimage 49 : 1271 – 1281 . 19819338
20 Helms G , Dathe H , Dechent P ( 2008 ) Quantitative FLASH MRI at 3T using a rational approximation of the Ernst equation. Magn. Reson. Med . 59 : 667 – 672 .
21 Wang JH , Qiu M , Kim H , Constable RT ( 2006 ) T1 measurements incorporating flip angle calibration and correction in vivo. J. Magn. Reson . Imaging 182 : 283 – 292 .
22 Firbank MJ , Coulthard A , Harrison RM , Williams ED ( 1999 ) A comparison of two methods for measuring the signal to noise ratio on MR images. Phys Med Biol . 44 : N261 – 264 .
23 Kim KA , Herigault G , Kim MJ , Chung YE , Hong HS , et al ( 2011 ) Three-dimensional contrast-enhanced hepatic MR imaging: comparison between a centric technique and a linear approach with partial Fourier along both slice and phase directions . J Magn Reson Imaging 33 : 160 – 166 . 21182134
24 Moratal D , Valles-Luch A , Marti-Bonmati L , Brummer M ( 2008 ) k-Space tutorial: an MRI educational tool for a better understanding of k-space . Biomed Imaging Interv J 4 : e15 . 21614308
25 Constable RT , Gore JC ( 1992 ) The Loss of Small Objects in Variable Te Imaging - Implications for Fse, Rare, and Epi. Magn. Reson. Med . 28 : 9 – 24 .
26 Hennig J ( 1999 ) K-space sampling strategies. Eur. Radiol . 9 : 1020 – 1031 .
27 Stocker T , Shah NJ ( 2006 ) MP-SAGE: A new MP-RAGE sequence with enhanced SNR and CNR for brain imaging utilizing square-spiral phase encoding and variable flip angles. Magn. Reson. Med . 56 : 824 – 834 .
28 Yang QX , Dardzinski BJ , Li S , Eslinger PJ , Smith MB ( 1997 ) Multi-gradient echo with susceptibility inhomogeneity compensation (MGESIC): demonstration of fMRI in the olfactory cortex at 3.0 T. Magn Reson Med . 37 : 331 – 335 .
29 Zur Y , Wood ML , Neuringer LJ ( 1991 ) Spoiling of transverse magnetization in steady-state sequences. Magn Reson Med . 21 : 251 – 263 .
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
오픈액세스 학술지에 출판된 논문