NTIS 바로가기Annals of rehabilitation medicine, v.35 no.3, 2011년, pp.412 - 417
Park, Giburm (Department of Rehabilitation Medicine, Hanyang University College of Medicine, Guri 471-701, Korea.) , Kim, Chan Woo (Department of Rehabilitation Medicine, Hanyang University College of Medicine, Guri 471-701, Korea.) , Park, Si Bog (Department of Rehabilitation Medicine, Hanyang University College of Medicine, Guri 471-701, Korea.) , Kim, Mi Jung (Department of Rehabilitation Medicine, Hanyang University College of Medicine, Guri 471-701, Korea.) , Jang, Seong Ho (Department of Rehabilitation Medicine, Hanyang University College of Medicine, Guri 471-701, Korea.)
ObjectiveTo assess the usefulness of a pressure algometer to measure pressure pain threshold (PPT) for diagnosis of myofascial pain syndrome (MPS) in the upper extremity and trunk muscles.MethodA group of 221 desk workers complaining of upper body pain participated in this study. Five physiatrists m...
1 Ohara H Nakagiri S Itani T Wake K Aoyama H Occupational health hazards resulting from elevated work rate situations J Hum Ergol (Tokyo) 1976 5 173 182 143492
2 Onishi N Nomura H Sakai K Yamamoto T Hirayama K Itani T Shoulder muscle tenderness and physical features of female industrial workers J Hum Ergol (Tokyo) 1976 5 87 102 1030453
3 Bechtol CO Grip test; the use of a dynamometer with adjustable handle spacing J Bone Joint Surg Am 1954 36 820 824 13174611
4 Sola AE Bonica JJ Myofascial pain syndromes The management of pain 1990 2nd ed Philadelphia Lea & Febiger 352
5 Hogeweg JA Langereis MJ Bernards AT Faber JA Helders PJ Algometry. Measuring pain threshold, method and characteristics in healthy subject Scand J Rehabil Med 1992 24 99 103 1604268
6 Fischer AA Pressure threshold meter: its use for quantification of tender spots Arch Phys Med Rehabil 1986 67 836 838 3778185
7 Han TR Kim JH Chun MH Choi KH Pain threshold using a pressure algometer in normal Korean young adults J Korean Acad Rehabil Med 1994 18 219 226
8 Lee GH Park SB Lee SG Lee KM Roh SC Song J Pressure threshold, grip and pinch strength in female telephone operators J Korean Acad Rehabil Med 1997 21 589 593
9 Buchanan HM Midgley JA Evaluation of pain threshold using a simple pressure algometer Clinical Rheumatology 1987 6 510 517 3449302
10 Chesterton LS Barlas P Foster NE Baxter GD Wright CC Gender differences in pressure pain threshold in healthy humans Pain 2003 101 259 266 12583868
11 Chung SC Um BY Kim HS Evaluation of pressure pain threshold in head and neck muscles by electronic algometer: intrarater and interrater reliability Cranio 1992 10 28 34 1302649
12 Chesterton LS Sim J Wright CC Foster NE Interrater reliability of algometry in measuring pressure pain thresholds in healthy humans, using multiple raters Clin J Pain 2007 23 760 766 18075402
13 Dagtekin O König E Gerbershagen HJ Marcus H Sabatowski R Petzke F Measuring pressure pain thresholds. Comparison of an electromechanically controlled algometer with established methods Schmerz 2007 21 439 444 17497183
14 Kinser AM Sands WA Stone MH Reliability and validity of a pressure algometer J Strength Cond Res 2009 23 312 314 19130648
15 Simons DG Travell JG Myofascial pain and dys function: the trigger point mannual 1999 2nd ed Baltimore Williams & Wilkins 19 44
16 Lee JH Lee JH Shin HS Yoon CH Oh MK Kwon SH Usefulness of electronic pressure algometer in evaluation of pressure pain threshold in normal Korean adults J Korean Acad Rehabil Med 2008 32 698 702
17 Kwon YE Lee SJ Yoon CS Lee JH Pressure pain threshold measurement using a pressure algometer in myofascial pain syndromes J Korean Pain Soc 2001 14 32 36
18 Reeves JL Jaeger B Graff-Radford SB Reliability of the pressure algometer as a measure of myofascial trigger point sensitivity Pain 1986 24 313 321 3960573
19 Delaney GA Mckee AC Inter- and intra-rater reliability of the pressure threshold meter in measurement of myofascial trigger point sensitivity Am J Phys Med Rehabil 1993 72 136 139 8512674
20 Vatine JJ Shapira SC Magora F Adler D Magora A Electronic pressure algometry of deep pain in healthy volunteers Arch Phys Med Rehabil 1993 74 526 530 8489364
21 Fischer AA Pressure algometry over normal muscles. Standard value, validity and reproducibility of pressure threshold Pain 1987 30 115 126 3614975