최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Korean journal of anesthesiology, v.65 no.3, 2013년, pp.237 - 243
Kim, Kyung Mi (Department of Anesthesiology and Pain Medicine, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Korea.) , Gwak, Mi Sook (Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.) , Choi, Soo Joo (Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.) , Kim, Myung Hee (Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.) , Park, Mi Hye (Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.) , Heo, Burn Young (Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.)
BackgroundDuring carotid endarterectomy (CEA), hemodynamic stability and adequate fluid management are crucial to prevent perioperative cerebral stroke, myocardial infarction and hyperperfusion syndrome. Both pulse pressure variation (PPV) and stroke volume variation (SVV), dynamic preload indices d...
1 Ederle J Dobson J Featherstone RL Bonati LH van der Worp HB de Borst GJ Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial Lancet 2010 375 985 997 20189239
2 Wilke HJ 2nd Ellis JE McKinsey JF Carotid endarterectomy: perioperative and anesthetic considerations J Cardiothorac Vasc Anesth 1996 10 928 949 8969405
3 Kumar A Anel R Bunnell E Habet K Zanotti S Marshall S Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects Crit Care Med 2004 32 691 699 15090949
4 Michard F Boussat S Chemla D Anguel N Mercat A Lecarpentier Y Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure Am J Respir Crit Care Med 2000 162 134 138 10903232
5 Michard F Teboul JL Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence Chest 2002 121 2000 2008 12065368
6 Osman D Ridel C Ray P Monnet X Anguel N Richard C Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge Crit Care Med 2007 35 64 68 17080001
7 Ellis JE Roizen MF Mantha S Schwarze ML Lubarsky DA Kenaan CA Anesthesia for vascular surgery Barash PG Cullen BF Stoelting RK Clinical anesthesia 5th ed Philadelphia Lippincott Williams & Wilkins 2006 933 973
8 Berkenstadt H Margalit N Hadani M Friedman Z Segal E Villa Y Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery Anesth Analg 2001 92 984 989 11273937
9 Signorelli SS Anzaldi M Fiore V Simili M Puccia G Libra M Patients with unrecognized peripheral arterial disease (PAD) assessed by ankle-brachial index (ABI) present a defined profile of proinflammatory markers compared to healthy subjects Cytokine 2012 59 294 298 22595645
10 Biais M Nouette-Gaulain K Cottenceau V Revel P Sztark F Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation Br J Anaesth 2008 101 761 768 18852114
11 Manecke GR Edwards FloTrac sensor and Vigileo monitor: easy, accurate, reliable cardiac output assessment using the arterial pulse wave Expert Rev Med Devices 2005 2 523 527 16293062
12 Manecke GR Jr Auger WR Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration J Cardiothorac Vasc Anesth 2007 21 3 7 17289472
13 Reuter DA Felbinger TW Schmidt C Kilger E Goedje O Lamm P Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery Intensive Care Med 2002 28 392 398 11967591
14 Hanley JA McNeil BJ A method of comparing the areas under receiver operating characteristic curves derived from the same cases Radiology 1983 148 839 843 6878708
15 Jellish WS Sheikh T Baker WH Louie EK Slogoff S Hemodynamic stability, myocardial ischemia, and perioperative outcome after carotid surgery with remifentanil/propofol or isoflurane/fentanyl anesthesia J Neurosurg Anesthesiol 2003 15 176 184 12826964
16 Lee JJ Kim GH Kim GS Lee BD The effects of intravascular volume expansion on the stability of hemodynamic responses in patients undergoing carotid endarterectomy Korean J Anesthesiol 2004 47 351 355
17 Derichard A Robin E Tavernier B Costecalde M Fleyfel M Onimus J Automated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery Br J Anaesth 2009 103 678 684 19797246
18 Khwannimit B Bhurayanontachai R Prediction of fluid responsiveness in septic shock patients: comparing stroke volume variation by FloTrac/Vigileo and automated pulse pressure variation Eur J Anaesthesiol 2012 29 64 69 21946822
19 Lahner D Kabon B Marschalek C Chiari A Pestel G Kaider A Evaluation of stroke volume variation obtained by arterial pulse contour analysis to predict fluid responsiveness intraoperatively Br J Anaesth 2009 103 346 351 19628484
20 Zhang Z Lu B Sheng X Jin N Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis J Anesth 2011 25 904 916 21892779
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
오픈액세스 학술지에 출판된 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.