NTIS 바로가기Earthquake engineering & structural dynamics, v.45 no.10, 2016년, pp.1581 - 1601
Kasai, Kazuhiko (Structural Engineering Research Center, Tokyo Institute of Technology, Yokohama, Japan) , Nam, Tran‐Tuan (Department of Built Environment, Tokyo Institute of Technology, Yokohama, Japan) , Maison, Bruce F. (Department of Built Environment, Tokyo Institute of Technology, Yokohama, Japan)
SummaryThis paper presents three‐dimensional nonlinear dynamic analyses of a full‐scale four‐story steel building tested to collapse in 2007 at the E‐Defense shake‐table facility in Japan, using strong ground motion. Local buckling and consequent strength deterioration ...
Kasai K , Ooki Y , Motoyui S , Takeuchi T , Sato E . E‐Defense tests on full‐scale steel buildings, part 1 ‐ experiments using dampers and isolators . Proceedings of Structural Congress , 247‐17 . ASCE : Long Beach , 2007 .
Suita K , Matsuoka Y , Yamada S , Shimada Y , Tada M , Kasai K . Experimental procedure and elastic response characteristics of shaking table test – complete collapse test of full‐scale 4‐story steel building part 1 (in Japanese) . Journal of Structural and Construction Engineering, Transactions of AIJ 2009 ; 635 : 157 – 166 .
Yamada S , Suita K , Matsuoka Y , Shimada Y . Elasto‐plastic responses and process leading to a collapse mechanism – complete collapse test of full‐scale 4‐story steel building part 2 (in Japanese) . Journal of Structural and Construction Engineering, Transactions of AIJ 2009 ; 644 : 1851 – 1859 .
Shimada Y , Suita K , Yamada S , Matsuoka Y , Tada M , Ohsaki M , Kasai K . Collapse behavior on shaking table test – complete collapse test of full‐scale 4‐story steel building part 3 (in Japanese) . Journal of Structural and Construction Engineering, Transactions of AIJ 2010 ; 653 : 1351 – 1360 .
Maison BF , Kasai K , Deierlein G . ASCE‐41 and FEMA‐351 evaluation of E‐Defense collapse test . Earthquake Spectra 2009 ; 25 ( 4 ): 927 – 953 .
Lignos GD , Hikino T , Matsuoka Y , Nakashima M . Collapse assessment of steel moment frames based on E‐Defense full‐scale shake table collapse test . Journal of Structural Engineering 2013 ; 139 : 120 – 132 .
Tada M , Tamai H , Ohgami K , Kuwahara S , Horimoto A . Analytical simulation utilizing collaborative structural analysis system . Proceedings of the 14 th World Conference on Earthquake Engineering . : Beijing , 2008 .
Pan P , Ohsaki M , Zhang J . Collapse analysis of 4‐story steel moment‐resisting frames . Proceedings of the 14 th World Conference on Earthquake Engineering . : Beijing , 2008 .
Isobe D , Han WS , Miyamura T . Verification and validation of a seismic response analysis code for framed structures using the ASI‐Gauss technique . Earthquake Engineering & Structural Dynamics 2013 ; 42 ( 12 ): 1767 – 1784 .
Yu YJ , Tsai KC , Weng YT , Lin BZ , Lin JL . Analytical studies of a full‐scale steel building shaken to collapse . Engineering Structures 2010 ; 32 : 3418 – 3430 .
Chen X , Han X , Jack C , Lin S , Mao G . Dynamic inelastic numerical simulation for a shaking table test of a full scale steel moment frame structure based on OpenSEES . Proceedings of the 14 th World Conference on Earthquake Engineering . : Beijing , 2008 .
Uriz P , Filippou FC , Mahin SA . Model for cyclic inelastic buckling of steel braces . Journal of Structural Engineering 2008 ; 134 ( 4 ): 619 – 628 .
Spacone E , Filippou FC , Taucer FF . Fibre beam‐column model for non‐linear analysis of R/C frames: Part I. Formulation . Earthquake Engineering & Structural Dynamics 1996 ; 25 ( 7 ): 711 – 726 .
Liang QQ , Uy B , Liew JYR . Nonlinear analysis of concrete‐filled thin‐walled steel box columns with local buckling effects . Journal of Constructional Steel Research 2006 ; 62 ( 6 ): 581 – 591 .
Hajjar JF , Gourley BC . Representation of concrete‐filled steel tube cross‐section strength . Journal of Structural Engineering 1996 ; 122 ( 11 ): 1327 – 1336 .
Varma AH , Ricles JM , Sause R , Lu LW . Seismic behavior and modeling of high‐strength composite concrete‐filled steel tube (CFT) beam–columns . Journal of Constructional Steel Research 2002 ; 58 ( 5 ): 725 – 758 .
Uy B . Local and post‐local buckling of concrete filled steel welded box columns . Journal of Constructional Steel Research 1998 ; 47 ( 1 ): 47 – 72 .
Kunnath SK , Heo Y , Mohle JF . Nonlinear uniaxial material model for reinforcing steel bars . Journal of Structural Engineering 2009 ; 135 ( 4 ): 335 – 343 .
Monti G , Nuti C . Nonlinear cyclic behavior of reinforcing bars including buckling . Journal of Structural Engineering 1992 ; 118 ( 12 ): 3268 – 3284 .
PERFORM . Components and Elements for PERFORM‐3D and PERFORM‐Collapse, Version 4 . CSI (Computers Structures) INC : Walnut Creek, CA , 2006 .
Black RG , Wenger WA , Popov EP . Inelastic Buckling of Steel Struts Under Cyclic Load Reversals UCB/EERC‐80/40. Earthquake Engineering Research Center : Berkeley, California , 1980 .
Yamada S , Akiyama H , Kuwamura H . Post‐buckling and deteriorating behavior of box‐section steel members (in Japanese) . Journal of Structural and Construction Engineering, Transactions of AIJ 1993 ; 444 : 135 – 143 .
Yamada S , Ishida T , Shimada Y , Matsunaga T . Cyclic loading test on RHS columns under bi‐directional horizontal forces (in Japanese) . Journal of Structural and Construction Engineering, Transactions of AIJ 2013 ; 683 : 203 – 212 .
Maison BF . PC‐ANSR: a computer program for nonlinear structural analysis . National Information Service for Earthquake Engineering, NISEE/Computer Applications, University of California, Berkeley, 1992 .
Architectural Institute of Japan . Recommendation for Limit State Design of Steel Structures (in Japanese). AIJ : Tokyo , 2010 .
Matsuoka Y , Suita K , Yamada S , Shimada Y , Akazawa M , Matsumiya T . Evaluation of seismic performance of exterior cladding in full‐scale 4‐story building shaking table test (in Japanese) . Journal of Structural and Construction Engineering, Transactions of AIJ 2009 ; 641 : 1353 – 1361 .