NTIS 바로가기Microchemical journal, v.131, 2017년, pp.170 - 173
An, J. , Lee, H. , Nam, K. , Yoon, H.O.
In the analysis of arsenic (As) with ICP-MS, it was observed that methanol addition to the sample decreases the amount of (ArCl+)-Ar-40-Cl-35 formed in the previous study. To investigate the effect of methanol addition on generation of isobaric polyatomic ions and its mechanism, a diluted HG solutio...
Talanta Mandal 58 201 2002 10.1016/S0039-9140(02)00268-0 Arsenic round the world: a review
Environ. Geochem. Health Das 18 5 1996 10.1007/BF01757214 Arsenic in groundwater in six districts of West Bengal, India
Appl. Geochem. Smedley 17 517 2002 10.1016/S0883-2927(02)00018-5 A review of the source, behaviour and distribution of arsenic in natural waters
Water Res. Katsoyiannis 36 5141 2002 10.1016/S0043-1354(02)00236-1 Removal of arsenic from contaminated water sources by sorption onto iron-oxide-coated polymeric materials
Talanta Hung 64 269 2004 10.1016/j.talanta.2004.01.027 Analytical methods for inorganic arsenic in water: a review
Microchem. J. An 120 77 2015 10.1016/j.microc.2015.01.001 Combined use of collision cell technique and methanol addition for the analysis of arsenic in a high-chloride-containing sample by ICP-MS
Microchem. J. Chen 87 87 2007 10.1016/j.microc.2007.05.011 Elimination of chloride interference on arsenic speciation in ion chromatography inductively coupled mass spectrometry using an octopole collision/reaction system
Microchem. J. Pick 95 315 2010 10.1016/j.microc.2010.01.008 Reduction of polyatomic interferences in biological material using dynamic reaction cell ICP-MS
Kim 2011 The study on trace heavy metal analysis and arsenic speciation using ICP-MS
Spectrochim. Acta B Atom. Spectrom. Fialho 66 389 2011 10.1016/j.sab.2011.04.001 Combination of cool plasma and collision-reaction interface for correction of polyatomic interferences on copper signals in inductively coupled plasma quadrupole mass spectrometry
J. Anal. At. Spectrom. Xie 17 1037 2002 10.1039/B202172B Determination of five arsenic species in aqueous samples by HPLC coupled with a hexapole collision cell ICP-MS
Microchem. J. Guo 97 154 2011 10.1016/j.microc.2010.08.003 Removal of spectral interferences and accuracy monitoring of trace cadmium in feeds by dynamic reaction cell inductively coupled plasma mass spectrometry
Talanta Guo 84 887 2011 10.1016/j.talanta.2011.02.026 Use of ion-molecule reactions and methanol addition to improve arsenic determination in high chlorine food samples by DRC-ICP-MS
Anal. Chim. Acta Pettine 599 191 2007 10.1016/j.aca.2007.08.016 Dissolved inorganic carbon effect in the determination of arsenic and chromium in mineral waters by inductively coupled plasma-mass spectrometry
Trac-Trends Anal. Chem. McSheehy 22 191 2003 10.1016/S0165-9936(03)00404-7 The speciation of arsenic in biological tissues and the certification of reference materials for quality control
Talanta Salazar 86 241 2011 10.1016/j.talanta.2011.09.009 Performance evaluation of collision-reaction interface and internal standardization in quadrupole ICP-MS measurements
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.