NTIS 바로가기International journal of refrigeration = Revbue internationale du froid, v.78, 2017년, pp.157 - 165
Yoo, Jin Woo (Corresponding author. Department of Mechanical and Aerospace Engineering, Seoul National University, Seoul 08826, Republic of Korea. Fax: +82-2-873-2178.) , Hong, Sung Bin , Kim, Min Soo
Refrigerant leakage is the most frequently found fault in a refrigeration system and efficient detection is highly important. For a sudden leakage, it is relatively easy to detect but slow and long-term leakage is hard to find out, therefore, a useful method for leak detection in such condition is r...
ANSI/AMCA 210 2007 Laboratory Methods of Testing Fans for Certified Aerodynamic Performance Rating
ASHRAE Guideline 2 2010 Engineering Analysis of Experimental Data
ASHRAE Handbook 2009 Fundamentals
Anal. Chem Bender 75 5262 2003 10.1021/ac034542l Selective detection of HFC and HCFC refrigerants using a surface acoustic wave sensor system
Explor. Econ. Hist Biddle 45 402 2008 10.1016/j.eeh.2008.02.004 Explaining the spread of residential air conditioning, 1955-1980
Int. J. Refrigeration Cho 28 1266 2005 10.1016/j.ijrefrig.2005.09.011 Effects of refrigerant charge amount on the performance of a transcritical CO2 heat pump
Comstock 1999 Development of analysis tools for the evaluation of fault detection and diagnostics for chillers
Int. J. Refrigeration Corberán 31 716 2008 10.1016/j.ijrefrig.2007.12.011 Charge optimisation study of a reversible water-to-water propane heat pump
Int. J. Refrigeration Corberán 34 881 2011 10.1016/j.ijrefrig.2011.01.009 Influence of the source and sink temperatures on the optimal refrigerant charge of a water-to-water heat pump
Appl. Therm. Eng Grace 25 557 2005 10.1016/j.applthermaleng.2004.07.008 Sensitivity of refrigeration system performance to charge levels and parameters for on-line leak detection
ISO 5151 2010 Non-ducted air conditioners and heat pumps - testing and rating for performance
Int. J. Refrigeration Kim 40 254 2014 10.1016/j.ijrefrig.2013.10.002 The effect of the refrigerant charge amount on single and cascade cycle heat pump systems
Int. J. Refrigeration Kim 30 43 2007 10.1016/j.ijrefrig.2006.06.008 Circulation concentration of CO2/propane mixtures and the effect of their charge on the cooling performance in an air-conditioning system
Int. J. Air-Cond. Ref Kim 24 4 1650027 2016 10.1142/S2010132516500279 Application of the natural refrigerant mixture R-290/DME to a soft ice cream refrigerator
Lemmon 2013 NIST Standard Reference Database 23: Reference Fluid Thermodynamic and Transport Properties-REFPROP, Version 9.1
J. Am. Assoc. Lab. Anim Rasmussen 46 5 64 2007 Using a refrigerant leak detector to monitor waste gases from halogenated anesthetics
Int. J. Refrigeration Roh 35 434 2012 10.1016/j.ijrefrig.2011.10.013 Comparison of the heating performance of an inverter-driven heat pump system using R410A vapor-injection into accumulator and compressor
Rossi 2004 Unitary air conditioner field performance
HVAC&R Res Rossi 3 1 19 1997 10.1080/10789669.1997.10391359 A statistical, rule-based fault detection and diagnostic method for vapor compression air conditioners
Int. J. Air-Cond. Ref Senthilkumar 25 1 1750007 2017 10.1142/S2010132517500079 Influence of silicon carbide nanopowder in R134a refrigerant used in vapor compression refrigeration system
Int. J. Air-Cond. Ref Sharifian 23 2 1550015 2015 10.1142/S2010132515500157 Impacts of room temperature on the performance of a portable propane air conditioner
Int. J. Refrigeration Tassou 28 680 2005 10.1016/j.ijrefrig.2004.12.007 Fault diagnosis and refrigerant leak detection in vapour compression refrigeration systems
U.S Energy Information Administration 2012 Annual Energy Review 2011