NTIS 바로가기Journal of biomedical materials research, v.26 no.9, 1992년, pp.1131 - 1139
Taira, Masayuki (Division of Biological Materials, Northwestern University, 311 E. Chicago Ave., Chicago, Illinois 60611) , Lautenschlager, Eugene P. (Division of Biological Materials, Northwestern University, 311 E. Chicago Ave., Chicago, Illinois 60611)
AbstractThe corrosion resistance of 316L cold worked stainless steel depends upon its thin protective oxide layer; and if this is partially broken down, corrosion resistance depends upon its tendency for repassivation. Since the intended function of stainless‐steel implants is to sustain muscu...
1 A. C. Fraker and N. W. Ruff ,“ Metallic surgical implants—state of the art ,” J. Metals , 29 ( 5 ), 22 – 28 ( 1977 ).
2 H. S. Dobbs and J. T. Scales ,“ Fracture and corrosion in stainless steel total hip replacement stems ,” Corrosion and Degradation of Implant Materials , B. C. Syrett and A. Acharya (eds.),ASTM STP 684,ASTM Philadelphia , 1979 ,pp. 248 – 258 .
3 P. Ducheyne , P. D. Meester , and E. Aernoudt ,“ Performance analysis of total hip prostheses: some particular metallurgical observations ,” J. Biomed. Mater. Res. , 14 , 31 – 40 ( 1980 ).
4 P. Ducheyne , P. D. Meester , and E. Aernoudt ,“ Fatigue fractures of the femoral component of Charnley and Charnley Muller type total hip prostheses ,” J. Biomed. Mater. Res. Symp. , 6 , 199 – 219 ( 1975 ).
5 J. T. Scales and G. P. Winter ,“ Corrosion of orthopedic implants ,” J. Bone Joint Surg. , 41B , 810 – 820 ( 1959 ).
6 A. Weinstein , H. Amstutz , G. Pavon , and V. Franceschini ,“ Orthopedic implants— A clinical and metallurgical analysis ,” J. Biomed. Mater. Res. , 4 , 297 – 325 ( 1973 ).
7 R. T. Gray ,“ Metallographic examinations of retrieved intramedullary bone pins and bone screws from the human body ,” J. Biomed. Mater. Res. Symp. , 5 , 27 – 38 ( 1974 ).
8 G. D. Winter ,“ Tissue reactions to metallic wear and corrosion products in human patients ,” J. Biomed. Mater. Res. Symp. , 5 , 11 – 25 ( 1974 ).
9 D. F. Williams and G. Meachim ,“ A combined metallurgical and histological study of tissue‐prosthesis interactions in orthopedic patients ,” J. Biomed. Mater. Res. Symp. , 5 , 1 – 9 ( 1974 ).
10 R. Duetman , T. J. Mulder , R. Brian , and J. P. Nater ,“ Metal sensitivity before and after total hip arthroplasty ,” J. Bone Joint Surg. , 59 ( A ), 862 – 865 ( 1977 ).
11 J. E. Lemons , K. M. W. Nieman , and A. B. Weiss ,“ Biocompatibility studies on surgical grade titanium, cobalt and iron‐base alloys ,” J. Biomed. Mater. Res. Symp. , 7 , 549 – 553 ( 1976 ).
12 A. W. Weinstein , W. P. Spires , J. J. Klawitter , A. J. T. Clemow , and J. O. Edmunds ,“ Orthopedic implant retrieval and analysis study ,” Corrosion and Degradation of Implant Materials , B. C. Syrett and A. Acharya (eds.),ASTM STP 684,ASTM, Philadelphia , 1979 ,pp. 212 – 228 .
13 Standard method of test for pitting and crevice corrosion of metallic surgical materials ,ASTM‐F746, Philadelphia , 1987 .
14 Source Book on Stainless Steels , Amer. Soc. for Metals Park , Ohio , 1976 ,pp. 172 – 173 .
15 M. S. Bapna , E. P. Lautenschlager , and J. B. Moser ,“ The influence of electrical potential and surface finish on the fatigue life of surgical implant materials ,” J. Biomed. Mater. Res. , 9 , 611 – 621 ( 1975 ).
16 D. C. Mears ,“ Metals in medicine and surgery, review 218 ,” Int. Metals Rev. , 22 , 119 – 155 ( 1977 ).
17 E. H. Greener , J. K. Harcourt , and E. P. Lautenschlager , Materials Science in Dentistry , Williams and Wilkins , Baltimore , 1972 ,p. 363 .