NTIS 바로가기The British journal of radiology, v.85 no.1019 = no.1019, 2012년, pp.e1067 - e1073
Palmer, A (Medical Physics Department, Queen Alexandra Hospital, Portsmouth Hospitals NHS Trust, Portsmouth, UK) , Kearton, J (Medical Physics Department, Queen Alexandra Hospital, Portsmouth Hospitals NHS Trust, Portsmouth, UK) , Hayman, O (Medical Physics Department, Queen Alexandra Hospital, Portsmouth Hospitals NHS Trust, Portsmouth, UK)
ObjectivesThe objective of this study was to determine current radiotherapy linear accelerator quality control (QC) practice in the UK, as a comparative benchmark and indicator of development needs, and to raise awareness of QC as a key performance indicator.MethodsAll UK radiotherapy centres were i...
1 Thomadsen B Critique of traditional quality assurance paradigm. Int J Radiation Oncology Biol Phys 2008 ; 71 : S166 – 9
2 Kapanen M Bly R Sipila P Jarvinen H Tenhunen M How can a cost/benefit ratio be optimized for an output measurement program of external photon radiotherapy beams? Phys Med Biol 2011 ; 56 : 2119 – 30 21389356
3 McKenzie A Briggs G Buchanan R Harvey L Iles A Kirby M Balancing costs and benefits of checking in radiotherapy. Report no. 92. York, UK : IPEM ; 2006
4 Blache L Robbins P Brown S Jones P Liu T LeFever J Risk management and its application to medical device management. Report no. 95. York, UK : IPEM ; 2008
5 Ishikura S Quality assurance of radiotherapy in cancer treatment: toward improvement of patient safety and quality of care. Jpn J Clin Oncol 2008 ; 38 : 723 – 9 18952706
6 Department of Health Quality, innovation, productivity and prevention (QIPP). London, UK : HMSO ; 2011 Available from: www.dh.gov.uk/en/Healthcare/Qualityandproductivity/QIPP/index.htm
7 Mayles WPM Lake R McKenzie A Macaulay EM Morgan HM Jordan TJ Physics aspects of quality control in radiotherapy. Report no. 81. York, UK : IPEM ; 1999
8 Klein EE Hanley J Yin F-F Simon W Dresser S Serago C Quality assurance of medical accelerators. AAPM Task Group 142 report. Med Phys 2009 ; 36 : 4197 – 212 19810494
9 Fan J Price RA Conventional linear accelerators. In: Pawlicki T Dunscombe PB Mundt AJ Scalliet P , (eds). Quality and safety in radiotherapy . Abingdon, UK : Taylor & Francis ; 2011
10 EU Guidance RP162 Radiation criteria for acceptability of medical radiological equipment used in diagnostic radiology, nuclear medicine and radiotherapy. European Commission Contract No. ENER/10/NUCL/SI2.581655. (Draft document not available for citation)
11 Williamson JF Dunscombe PB Sharpe MB Thomadsen BR Purdy JA Deye JA Quality assurance needs for modern image-based radiotherapy: recommendations from 2007 interorganizational symposium on “quality assurance of radiation therapy: challenges of advanced technology”. Int J Radiat Oncol Biol Phys 2008 ; 71 : S2 – 12 18406928
12 IPEM Radiotherapy Physics Topic Group Survey of quality control practice in UK hospitals. Scope 1992 ; 1 : 49 – 61 In: Mayles WPM Lake R McKenzie A Macaulay EM Morgan HM Jordan TJ Powley SK , (eds). Physics aspects of quality control in radiotherapy. Report no. 81. York, UK : IPEM ; 1999
13 Venables K Winefield E Deighton A Aird E Hoskin P A survey of radiotherapy quality control practice in the United Kingdom for the START trial. Radiother Oncol 2001 ; 60 : 311 – 18 11514011
14 NHS Institute for Innovation and Improvement Quality and service improvement tools: plan, do, study, act (PDS). Coventry, UK : NHS Institute ; 2008 Available from: www.institute.nhs.uk/quality_and_service_improvement_tools/quality_and_service_improvement_tools/plan_do_study_act.html
15 Aletti P Bey P Recommendations for a quality assurance programme in external beam radiotherapy. ESTRO booklet no. 2. Brussels, Belgium : ESTRO ; 1995 Available from: www.estro-education.org/publications/Documents/Booklet_n2.pdf
16 Kutcher GJ Coia L Gilin M Hanson WF Leibel S Morton RJ Comprehensive QA for radiation oncology. AAPM Task Group 40 report. Med Phys 1994 ; 21 Available from: http://www.aapm.org/pubs/reports/rpt_46.pdf
17 Hiles P Mackenzie A Scally A Wall B Recommended standards for the routine performance testing of diagnostic x-ray imaging systems. Report no. 91 York, UK : IPEM ; 2005
18 Kirby M Carpenter D Lawrence G Poynter A Studdart P Guidance for commissioning and QA of a networked radiotherapy department. Report no. 93. York, UK : IPEM ; 2006
19 Kirby M Ryde S Hall C Acceptance testing and commissioning of linear accelerators. Report no. 94 York, UK : IPEM ; 2007
20 James H Beavis A Budgell G Clark C Convery D Mott J Guidance for the clinical implementation of intensity modulated radiation therapy. Report no. 96. York, UK : IPEM ; 2008
21 Aspradakis MM (ed). Small field MV photon dosimetry. Report no. 103. York, UK : IPEM ; 2010