최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Journal of applied clinical medical physics, v.19 no.4, 2018년, pp.114 - 124
Shukaili, Khalsa Al (Centre for Medical Radiation Physics University of Wollongong Wollongong NSW Australia) , Corde, Stéphanie (Centre for Medical Radiation Physics University of Wollongong Wollongong NSW Australia) , Petasecca, Marco (Centre for Medical Radiation Physics University of Wollongong Wollongong NSW Australia) , Pereveratylo, Vladimir (SPA BIT Ukraine) , Lerch, Michael (Centre for Medical Radiation Physics University of Wollongong Wollongong NSW Australia) , Jackson, Michael (Centre for Medical Radiation Physics University of Wollongong Wollongong NSW Australia) , Rosenfeld, Anatoly (Centre for Medical Radiation Physics University of Wollongong Wollongong NSW Australia)
AbstractPurposeTo investigate the accuracy of the dosimetry of radiation fields produced by small ELEKTA cone collimators used for stereotactic radiosurgery treatments (SRS) using commercially available detectors EBT3 GafchromicTM film, IBA Stereotactic diode (SFD), and the recently developed detect...
1 Das IJ , Morales J , Francescon P . Small field dosimetry: what have we learnt? AIP Conf Proc . 2016 ; 1747 : 060001 .
2 Andreo P , Huq MS , Westermark M , et al. Protocols for the dosimetry of high‐energy photon and electron beams: a comparison of the IAEA TRS‐398 and previous international Codes of Practice . Phys Med Biol . 2002 ; 47 : 3033 – 3053 . 12361209
3 Almond PR , Biggs PJ , Coursey BM , et al. AAPM's TG‐51 protocol for clinical reference dosimetry of high‐energy photon and electron beams . Med Phys . 1999 ; 26 : 1847 – 1870 . 10505874
4 Benmakhlouf H , Sempau J , Andreo P . Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: a PENELOPE Monte Carlo study . Med Phys . 2014 ; 41 : 041711 . 24694131
5 Francescon P , Cora S , Cavedon C . Total scatter factors of small beams: a multidetector and Monte Carlo study . Med Phys . 2008 ; 35 : 504 – 513 . 18383671
6 Francescon P , Kilby W , Satariano N . Monte Carlo simulated correction factors for output factor measurement with the CyberKnife system—Results for new detectors and correction factor dependence on measurement distance and detector orientation . Phys Med Biol . 2014 ; 59 : N11 – N17 . 24594929
7 Das I . TH‐A‐213‐00: small field dosimetry: overview of AAPM TG‐155 and the IAEAAAPM Code of Practice . Med Phys . 2015 ; 42 : 3700 .
8 Goetsch S . TH‐A‐BRC‐02: AAPM TG‐178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance . Med Phys . 2016 ; 43 : 3852 – 3853 .
9 Aspradakis MM , Byrne JP , Palmans H , et al. IPEM Report 103: Small field MV photon dosimetry . 2010 .
10 IAEA TRS 483 . Dosimetry of small static fields used in external beam radiotherapy: an IAEA‐AAPM International Code of Practice for reference and relative dose determination, Technical Report Series No. 483 . IAEA ; Vienna, Austria ; 2017 .
11 McKerracher C , Thwaites DI . Assessment of new small‐field detectors against standard‐field detectors for practical stereotactic beam data acquisition . Phys Med Biol . 1999 ; 44 : 2143 – 2160 . 10495110
12 Bisello F , Menichelli D , Scaringella M , et al. Development of silicon monolithic arrays for dosimetry in external beam radiotherapy . Nucl Instrum Methods Phys Res, Sect A . 2015 ; 796 : 85 – 88 .
13 Bocci A , Cortés‐Giraldo MA , Gallardo MI , et al. Silicon strip detector for a novel 2D dosimetric method for radiotherapy treatment verification . Nucl Instrum Methods Phys Res, Sect A . 2012 ; 673 : 98 – 106 .
14 Manolopoulos S , Wojnecki C , Hugtenburg R , et al. Small field measurements with a novel silicon position sensitive diode array . Phys Med Biol . 2009 ; 54 : 485 . 19124947
15 Das IJ , Cheng CW , Watts RJ , et al. Accelerator beam data commissioning equipment and procedures: report of the TG‐106 of the Therapy Physics Committee of the AAPM . Med Phys . 2008 ; 35 : 4186 – 4215 . 18841871
16 Wilkins D , Li XA , Cygler J , Gerig L . The effect of dose rate dependence of p‐type silicon detectors on linac relative dosimetry . Med Phys . 1997 ; 24 : 879 – 881 . 9198022
17 Saini AS , Zhu TC . Dose rate and SDD dependence of commercially available diode detectors . Med Phys . 2004 ; 31 : 914 – 924 . 15125010
18 Shi J , Simon WE , Zhu TC . Modeling the instantaneous dose rate dependence of radiation diode detectors . Med Phys . 2003 ; 30 : 2509 – 2519 . 14528973
19 Grusell E , Rikner G . Evaluation of temperature effects in p‐type silicon detectors . Phys Med Biol . 1986 ; 31 : 527 .
20 Saini AS , Zhu TC . Temperature dependence of commercially available diode detectors . Med Phys . 2002 ; 29 : 622 – 630 . 11991134
21 Saini AS , Zhu TC . Energy dependence of commercially available diode detectors for in‐vivo dosimetry . Med Phys . 2007 ; 34 : 1704 – 1711 . 17555252
22 Griessbach I , Lapp M , Bohsung J , Gademann G , Harder D . Dosimetric characteristics of a new unshielded silicon diode and its application in clinical photon and electron beams . Med Phys . 2005 ; 32 : 3750 – 3754 . 16475774
23 Jursinic PA , Sharma R , Reuter J . MapCHECK used for rotational IMRT measurements: step‐and‐shoot, TomoTherapy, RapidArc . Med Phys . 2010 ; 37 : 2837 – 2846 . 20632595
24 Wolff T , Carter S , Langmack KA , Twyman NI , Dendy PP . Characterization and use of a commercial n‐type diode system . Br J Radiol . 1998 ; 71 : 1168 – 1177 . 10434912
25 Li Q , Deng X , Chen L , Huang X , Huang S . The angular dependence of a 2‐dimensional diode array and the feasibility of its application in verifying the composite dose distribution of intensity‐modulated radiation therapy . Chin J Cancer . 2010 ; 29 : 617 – 620 . 20507735
26 Jin H , Keeling VP , Johnson DA , Ahmad S . Interplay effect of angular dependence and calibration field size of MapCHECK 2 on RapidArc quality assurance . JACMP . 2014 ; 15 : 80 – 92 .
27 Zhang J . A new method to compensate angular dependence of MapCheck device in intensity modulated arc therapy . Med Phys . 2010 ; 37 : 3242 .
28 Zhou H , Wu C . Quantitative evaluation and correction of the gantry angular dependence of MapCheck2 for patient QA measurement . Med Phys . 2011 ; 38 : 3525 .
29 Petasecca M , Alhujaili S , Aldosari A , et al. Angular independent silicon detector for dosimetry in external beam radiotherapy . Med Phys . 2015 ; 42 : 2992 – 3004 . 26127052
30 Andreo P . The physics of small megavoltage photon beam dosimetry . Radiother Oncol . 2018 ; 126 : 205 – 213 . 29191457
31 Bouchard H , Seuntjens J , Duane S , Kamio Y , Palmans H . Detector dose response in megavoltage small photon beams. I. Theoretical Concepts . Med Phys . 2015 ; 42 : 6033 – 6047 . 26429279
32 Bouchard H , Kamio Y , Palmans H , Seuntjens J , Duane S . Detector dose response in megavoltage small photon beams. II. Pencil beam perturbation effects . Med Phys . 2015 ; 42 : 6048 – 6061 . 26429280
33 Liu PZ , Suchowerska N , McKenzie DR . Can small field diode correction factors be applied universally? Radiother Oncol . 2014 ; 112 : 442 – 446 . 25441057
34 Ralston A , Liu P , Warrener K , McKenzie D , Suchowerska N . Small field diode correction factors derived using an air core fibre optic scintillation dosimeter and EBT2 film . Phys Med Biol . 2012 ; 57 : 2587 . 22505592
35 Liu PZ , Reggiori G , Lobefalo F , et al. Small field correction factors for the IBA Razor . Phys Med . 2016 ; 32 : 1025 – 1029 . 27497923
36 Cranmer‐Sargison G , Weston S , Evans JA , Sidhu NP , Thwaites DI . Implementing a newly proposed Monte Carlo based small field dosimetry formalism for a comprehensive set of diode detectors . Med Phys . 2011 ; 38 : 6592 – 6602 . 22149841
37 Borzov E , Nevelsky A , Bar‐Deroma R , Orion I . Dosimetric characterization of Elekta stereotactic cones . JACMP . 2017 ; 19 : 194 – 203 . 29266744
38 Lechner W , Palmans H , Sölkner L , Grochowska P , Georg D . Detector comparison for small field output factor measurements in flattening filter free photon beams . Radiother Oncol . 2013 ; 109 : 356 – 360 . 24257020
39 Morales JE , Crowe SB , Hill R , Freeman N , Trapp JV . Dosimetry of cone‐defined stereotactic radiosurgery fields with a commercial synthetic diamond detector . Med Phys . 2014 ; 41 : 111702 . 25370616
40 Devic S , Tomic N , Lewis D . Reference radiochromic film dosimetry: review of technical aspects . Phys Med . 2016 ; 32 : 541 – 556 . 27020097
41 Al Shukaili K , Petasecca M , Newall M , et al. A 2D silicon detector array for quality assurance in small field dosimetry: DUO . Med Phys . 2017 ; 44 : 628 – 636 . 28152195
42 Tyler M , Liu PZ , Chan KW , et al. Characterization of small‐field stereotactic radiosurgery beams with modern detectors . Phys Med Biol . 2013 ; 58 : 7595 . 24107592
43 Benmakhlouf H , Andreo P . Spectral distribution of particle fluence in small field detectors and its implication on small field dosimetry . Med Phys . 2017 ; 44 : 713 – 724 . 28032369
44 Poppe B , Stelljes T , Foschepoth S , Looe H , Willborn K , Harder D . SU‐E‐T‐131: Iterative Deconvolution of Dose Profile Measurements with Ionization Chambers Based on Lorentz‐Type Lateral Response Functions of the Detectors . Med Phys . 2011 ; 38 : 3516 .
45 Wang LL , Leszczynski K . Estimation of the focal spot size and shape for a medical linear accelerator by Monte Carlo simulation . Med Phys . 2007 ; 34 : 485 – 488 . 17388165
46 Seco J , Verhaegen F . Monte Carlo Techniques in Radiation Therapy . Milton Park, UK : Taylor & Francis ; 2013 .
47 Herwiningsih S , Fielding A . Focal spot estimation of an Elekta dedicated stereotactic linear accelerator Monte Carlo model . J Phys . 2016 ; 694 : 012013 .
48 Halvorsen PH , Cirino E , Das IJ , et al. AAPM‐RSS Medical Physics Practice Guideline 9. a. for SRS‐SBRT . JACMP . 2017 ; 18 : 10 – 21 .
49 Scott AJ , Kumar S , Nahum AE , Fenwick JD . Characterizing the influence of detector density on dosimeter response in non‐equilibrium small photon fields . Phys Med Biol . 2012 ; 57 : 4461 . 22722374
50 Charles PH , Crowe SB , Kairn T , et al. The effect of very small air gaps on small field dosimetry . Phys Med Biol . 2012 ; 57 : 6947 . 23044638
51 Underwood TS , Thompson J , Bird L , et al. Validation of a prototype DiodeAir for small field dosimetry . Phys Med Biol . 2015 ; 60 : 2939 . 25789823
※ AI-Helper는 부적절한 답변을 할 수 있습니다.