NTIS 바로가기Journal of biomedical materials research. Part B, Applied biomaterials, v.107 no.3, 2019년, pp.825 - 837
Wang, Jingjing (Key Laboratory for Biorheological Science and Technology of Ministry of Education (Chongqing University), State and Local Joint Engineering Laboratory For Vascular Implants (Chongqing), Bioengineering College of Chongqing University, Chongqing, China) , Ren, Yuzhen (Key Laboratory for Biorheological Science and Technology of Ministry of Education (Chongqing University), State and Local Joint Engineering Laboratory For Vascular Implants (Chongqing), Bioengineering College of Chongqing University, Chongqing, China) , Huang, Yuhua (Key Laboratory for Biorheological Science and Technology of Ministry of Education (Chongqing University), State and Local Joint Engineering Laboratory For Vascular Implants (Chongqing), Bioengineering College of Chongqing University, Chongqing, China) , Du, Ruolin (Key Laboratory for Biorheological Science and Technology of Ministry of Education (Chongqing University), State and Local Joint) , Xi, Yadong , Yin, Tieying , Wang, Yazhou , Zhang, Dechuan , Chen, Jinju , Wang, Guixue
AbstractThis study aims to design an asymmetric dual coating (ADC) on the stent by ultrasonic atomization to solve the problem of delayed endothelialization and late or very late stent thrombosis which caused by drug eluting stent (DES) with symmetric coating. Chitosan‐loaded monoclonal platel...
Fuster V . Global burden of cardiovascular disease: time to implement feasible strategies and to monitor results . J Am Coll Cardiol 2014 ; 64 : 520 ‐ 522 .
Deaton C , Froelicher ES , Wu LH , Ho C , Shishani K , Jaarsma , T . The global burden of cardiovascular disease . Eur J Cardiovasc Nur 2011 ; 10 : S5 ‐ S13 .
Sheiban I , Villata G , Bollati M , Sillano D , Lotrionte M , Biondi‐Zoccai G . Next generation drug eluting stents in coronary artery disease focus on everolimus eluting stent . Vasc Health Risk Manag 2008 ; 4 : 31 ‐ 38 .
Khan W , Farah S , Domb AJ . Drug eluting stents: developments and current status . J Control Release 2012 ; 161 : 703 ‐ 712 .
Iqbal J , Gunn J , Serruys PW . Coronary stents: Historical development, current status and future directions . Br Med Bull 2013 ; 106 : 193 ‐ 211 .
Sun D , Zheng Y , Yin T , Tang C , Yu Q , Wang GX . Coronary drug‐eluting stents: From design optimization to newer strategies . J Biomed Mater Res A 2014 ; 102 : 1625 ‐ 1640 .
Spaulding C , Henry P , Teiger E , Beatt K , Bramucci E , Carrié D , Slama MS , Merkely B , Erglis A , Margheri M , Varenne O , Cebrian A , Stoll H , Snead DB , Bode C , Investigators T . Sirolimus‐eluting versus uncoated stents in acute myocardial infarction . N Engl J Med 2006 ; 355 : 1093 ‐ 1104 .
Ranade SV , Miller KM , Richard RE , Chan AK , Allen MJ , Helmus MN . Physical characterization of controlled release of paclitaxel from the TAXUS Express2 drug‐eluting stent . J Biomed Mater Res A 2004 ; 71 : 625 ‐ 634 .
Naganuma T , Fujino Y , Tahara S , Mitomo S , Basavarajaiah S , Nakamura S . Extremely late catch‐up phenomenon after first‐generation sirolimus‐eluting stent in the left main stem: Insights from optical coherence tomography . JACC Cardiovasc Interv 2015 ; 8 : e237 ‐ e239 .
De Luca G , Dirksen MT , Kelbæk H , Thuesen L , Vink MA , Kaiser C , Chechi T , Spaziani G , Di Lorenzo E , Suryapranata H , Stone GW . Paclitaxel‐eluting versus bare metal stents in primary PCI: A pooled patient‐level meta‐analysis of randomized trials . J Thromb Thromb 2015 ; 39 : 101 ‐ 112 .
Haiek C , Fernandez‐Pereira C , Santaera O , Mieres J , Rifourcat I , Lloberas J , Larribau M , Pocovi A , Rodriguez‐Granillo AM , Sarmiento RA , Antoniucci D , Rodriguez AE . Second vs. first generation drug eluting stents in multiple vessel disease and left main stenosis: Two‐year follow‐up of the observational, prospective, controlled, and multicenter ERACI IV registry . Catheter Cardiovasc Interv 2017 ; 89 : 37 ‐ 46 .
Meng M , Gao B , Wang X , Bai ZG , Sa RN , Ge B . Long‐term clinical outcomes of everolimus‐eluting stent versus paclitaxel‐eluting stent in patients undergoing percutaneous coronary interventions: a meta‐analysis . BMC Cardiovasc Disord 2016 ; 16 : 34 .
Pilgrim T , Piccolo R , Heg D , Roffi M , Tüller D , Vuilliomenet A , Muller O , Cook S , Weilenmann D , Kaiser C , Jamshidi P , Khattab AA , Taniwaki M , Rigamonti F , Nietlispach F , Blöchlinger S , Wenaweser P , Jüni P , Windecker S . Biodegradable polymer sirolimus‐eluting stents versus durable polymer everolimus‐eluting stents for primary percutaneous coronary revascularisation of acute myocardial infarction . EuroIntervention 2016 ; 12 : e1343 ‐ e1354 .
Cassese S , Desch S , Kastrati A , Byrne RA , King L , Tada T , Lauer B , Schomig A , Thiele H , Pache J . Polymer‐free sirolimus‐eluting versus polymer‐based paclitaxel‐eluting stents: an individual patient data analysis of randomized trials . Rev Esp Cardiol (Engl Ed). 2013 ; 66 : 435 ‐ 442 .
Kim SM , Park KS , Lih E , Hong YJ , Kang JH , Kim IH , Jeong MH , Joung YK , Han DK . Fabrication and characteristics of dual functionalized vascular stent by spatio‐temporal coating . Acta Biomater 2016 ; 38 : 143 ‐ 152 .
Zhang H , Deng W , Wang X , Wang S , Ge J , Toft E . Solely abluminal drug release from coronary stents could possibly improve reendothelialization . Catheter Cardiovasc Interv 2016 ; 88 : E59 ‐ 66 .
Wang GX , Luo LL , Yin TY , Li Y , Jiang T , Ruan CG , Guidoin R , Chen YP , Guzman R . Ultrasonic atomization and subsequent desolvation for monoclonal antibody (mAb) to the glycoprotein (GP) IIIa receptor into drug eluting stent . J Microencapsul 2010 ; 27 : 105 ‐ 114 .
Yin TY , Wang GX , Zhang DC , Du DY , Li ZG , Luo LL , Hou YB , Wang YZ , Zhao JB . Endothelialization and in‐stent restenosis on the surface of glycoprotein IIIa monoclonal antibody eluting stent . J Biomed Mater Res A. 2012 ; 100 : 1398 ‐ 1406 .
Tang C , Wang G , Wu X , Li Z , Shen Y ; Lee J , Yu Q . The impact of vascular endothelial growth factor‐transfected human endothelial cells on endothelialization and restenosis of stainless steel stents . J Vasc Surg, 2011 , 53 : 461 ‐ 471 .
McDonald RA , Halliday CA , Miller AM , Diver LA , Dakin RS , Montgomery J , McBride MW , Kennedy S , McClure JD , Robertson KE , Douglas G , Channon KM , Oldroyd KG , Baker AH . Reducing in‐stent restenosis: Therapeutic manipulation of miRNA in vascular remodeling and inflammation . J Am Coll Cardiol 2015 ; 65 : 2314 ‐ 2327 .
Simard T , Hibbert B , Ramirez FD , Froeschl M , Chen YX , O'Brien ER . The evolution of coronary stents: A brief review . Can J Cardiol 2014 ; 30 : 35 ‐ 45 .
Park , ES , Yoo , J‐M , Lim , Y , Tudev , M , Yoo , H‐S , Hong , JT , Yun , Y‐P . Inhibitory effects of docetaxel on platelet‐derived growth factor (PDGF)‐BB–induced proliferation of vascular smooth muscle cells through blocking PDGF‐receptor β phosphorylation . J Pharmacol Sci 2011 ; 116 : 204 ‐ 213 .
Luo LL , Wang GX , Li YL , Yin TY , Jiang T , Ruan CG . Layer‐by‐layer assembly of chitosan and platelet monoclonal antibody to improve biocompatibility and release character of PLLA coated stent . J Biomed Mater Res A 2011 ; 97 : 423 ‐ 432 .
Lozano , A , Amaveda , H , Barreras , F , Jordaà , X , Lozano , M . High‐frequency ultrasonic atomization with pulsed excitation . J Fluid Eng. 2003 ; 125 : 941 ‐ 945 .
Liu X , An G , Dong N , Shao B , Ruan C . The experimental research of inhibitory potency to rabbit thrombosis by McAb against human platelet membren glycoprotein IIIa . Jiangsu Med J , 2001 ; 4 : 270 ‐ 272 .
An G , Dong N , Ruan C . Construction and expression of a single chain antibody fragment of mAb SZ‐21 against platelets GP IIIa . Immunol J 2001 ; 17 : 200 ‐ 203 .
An G , Dong N , Shao B , Zhu M , Ruan C . Preparation and characterization of a single chain antibody fragment of mAb SZ‐21 against platelets GPIIIa . Chin J Hema , 2002 , 23 ( 9 ): 480 ‐ 482 .
Chaabane C , Otsuka F , Virmani R , Bochaton‐Piallat ML . Biological responses in stented arteries . Cardiovasc Res 2013 ; 99 : 253 ‐ 263 .
Alexander W , Michael G , Dsidra T . Plasma protein adsorption and platelet adhesionon poly[bis[trifiuoroethoxy) PhosPhazene] and reference material surfaces . J Colloid Interface Sci 1998 ; 197 : 263 ‐ 274 .
Ahmed F , Choudhury NR , Dutta NK , Brito e Abreu S , Zannettino A , Duncan E . Interaction of platelets with poly(vinylidene fluoride‐co‐hexafluoropropylene) electrospun surfaces . Biomacromolecules 2014 ; 15 : 744 ‐ 755 .
Nowak J , Watala C , Boncler M . Antibody binding, platelet adhesion, and protein adsorption on various polymer surfaces . Blood Coagul Fibrin 2014 ; 25 : 52 ‐ 60 .
Wang HG , Yin TY , Ge SP , Zhang Q , Dong QL , Lei DX , Sun DM , Wang GX . Biofunctionalization of titanium surface with multilayer films modified by heparin‐VEGF‐fibronectin complex to improve endothelial cell proliferation and blood compatibility . J Biomed Mater Res A. 2013 ; 101 : 413 ‐ 420 .
Shen L , Wu Y , Zhang F , Wu L , Dong C , Gao Y , Sun A , Zou Y , Qian J , Sun J , Zhong W , Ge J . Assessment of an asymmetrical coating stent with sirolimus released from ablumial matrix in porcine model . Clin Res Cardiol. 2012 ; 101 : 917 ‐ 927 .
Shi M , Yin F , Gu H , Zhu J , Yin X . Tissue factor pathway inhibitor‐coated stents inhibit restenosis in a rabbit carotid artery model . Cardiovasc Ther 2015 ; 33 : 353 ‐ 359 .
Ross R . The pathogenesis of atherosclerosis: A perspective for the 1990s . Nature 1993 ; 362 : 801 .
Glagov S . Intimal hyperplasia, vascular modeling, and the restenosis problem . Circulation 1994 ; 89 : 2888 ‐ 2891 .
Cho Y , Yang HM , Park KW , Chung WY , Choi DJ. Seo WW , Jeong KT , Chae SC , Lee MY , Hur SH , Chae JK , Seong IW , Yoon JH , Oh SK , Kim DI , Park KS , Rha SW , Jang YS , Bae JH , Hong TJ , Cho MC , Kim YJ , Jeong MH , Kim MJ , Park SK , Chae IH , Kim HS , Investigators. K . Paclitaxel‐ versus sirolimus‐eluting stents for treatment of ST‐segment elevation myocardial infarction: with analyses for diabetic and nondiabetic subpopulation . JACC Cardiovasc Interv 2010 ; 3 : 498 ‐ 506 .
Wang J , Liu L , Wu Y , Maitz MF , Wang Z , Koo Y , Zhao A , Sankar J , Kong D , Huang N , Yun Y . Ex vivo blood vessel bioreactor for analysis of the biodegradation of magnesium stent models with and without vessel wall integration . Acta Biomater 2017 ; 50 : 546 ‐ 555 .
Dick M , Jonak P , Leask RL . Statin therapy influences endothelial cell morphology and F‐actin cytoskeleton structure when exposed to static and laminar shear stress conditions . Life Sci 2013 ; 92 : 859 ‐ 865 .
Yang Y , Qi P , Wen F , Li X , Xia Q , Maitz MF , Yang Z , Shen R , Tu Q , Huang N . Mussel‐inspired one‐step adherent coating rich in amine groups for covalent immobilization of heparin: hemocompatibility, growth behaviors of vascular cells, and tissue response . ACS Appl Mater Interfaces. 2014 ; 6 : 14608 ‐ 14620 .
Osborn EA , Rabodzey A , Dewey CJ , Hartwig JH . Endothelial actin cytoskeleton remodeling during mechanostimulation with fluid shear stress . Am J Physiol Cell Physiolf 2006 ; 290 : C444 ‐ 452 .
해당 논문의 주제분야에서 활용도가 높은 상위 5개 콘텐츠를 보여줍니다.
더보기 버튼을 클릭하시면 더 많은 관련자료를 살펴볼 수 있습니다.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
저자가 공개 리포지터리에 출판본, post-print, 또는 pre-print를 셀프 아카이빙 하여 자유로운 이용이 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.