Abstract Air mixing in an air mixing chamber affects an air-conditioning system's performances. Low air mixing effectiveness is associated with several problems. In this study, modified statistical air mixing effectiveness is proposed. An experimental study and CFD (Computational fluid dynamics) si...
2017 ANSYS FLUENT MANUAL
42.1 2015 ASHRAE Handbook-HVAC Applications
2.2 2016 ASHRAE Handbook-HVAC System and Equipment
4.7 2016 ASHRAE Handbook-HVAC System and Equipment
16.2 2017 ASHRAE Handbook-Fundamentals
Boussinesq vol. 1 1897
Delaney 83 1984 Avoiding Coil Freeze up, Heating/Piping/Air-Conditioning
Environmental Protection Agency 126 1991 Building Air Quality: A Guide for Building Owners and Facility Managers
J. Res. Natl. Bur. Stand. (U.S.) Faison 70C 1 25 1966 A test apparatus for the study of forced air-mixing devices
Faison vol. 12 1967
Build. Sci. Ser. Faison 27 1970 Performance of louvered devices as air mixers, National Bureau of standards (US)
Felker 28 2009 Dampers and Airflow Control
Intell. Control Autom. Huang 9 1 2018 10.4236/ica.2018.91001 Active-disturbance-rejection-control for temperature control of the HVAC system
Jeon 2015 Air-conditioner Include Air Mixing Chamber (Patent)
ASHRAE J. Kao 28 1 100 1985 Sensor errors
ASHARE Trans. Kato 94 2 621 1988 New ventilation based on spatial distribution of contaminant concentration aided by numerical simulation efficiency scales
Launder 1972 Lectures in Mathematical Models of Turbulence
Lee 2013 An Air Conditioner of Multi-Function and its Operational Method There (Patent)
J. Energies Lee 11 9 2018 Development of economizer control method with variable mixed air temperature
No 1999 An Air Conditioning Equipment (Patent)
J. SAREK Park 18 12 999 2006 An experimental study of temperature profiles in mixing zone of AHU with an air mixer
J. Fluids Eng. Patrick 108 1 1 1986 Editorial policy statement on the control of numerical accuracy
Phalak 2016 Control Method to Improve Non-linear HVAC System Operation
ASHRAE Transact. Robinson 104 pt. 1A 629 1998 Damper control characteristics and mixing effectiveness of an air-handling unit combination mixing/filter box
Robinson 63 2000 Rating Air-Mixing Equipment
Proceedings: Indoor Air Sun 358 2002 Outdoor and return airflow mixing with parallel dampers
Tritton 1988 Physical Fluid Dynamics
J. Control Sci. Eng. Wang 2016 1 2016 Application of residual-based EWMA control charts for detecting faults in variable-air-volume Air handling unit system
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.