NTIS 바로가기The Journal of chemical thermodynamics, v.141, 2020년, pp.105934 -
Steur, Peter P.M. (Istituto Nazionale di Ricerca Metrologica (INRiM)) , Yang, Inseok (Korea Research Institute of Standards and Science) , Giraudi, Domenico (Istituto Nazionale di Ricerca Metrologica (INRiM)) , Pavese, Franco (Independent Scientist)
Abstract For the first time, high-precision measurements were performed on the temperature of the α–β transition of oxygen, both pure and affected by different amount concentrations of Ar impurity up to an amount concentration x(Ar) ≈ 1·10−3 mol. The aim of this ...
Metrologia Pavese 46 47 2009 10.1088/0026-1394/46/1/007 Critical review of information relevant to the correction of the effect of chemical impurities in gases used for the realization of ITS-90 fixed points
Metrologia Pavese 48 268 2011 10.1088/0026-1394/48/5/005 Methods for the assessment of correction for chemical-impurity effects and related uncertainty in ITS-90 fixed points, namely of e-H2, Ne, O2 and Ar
Accred. Qual. Assur. Shimosaka 22 5 281 2017 10.1007/s00769-017-1279-3 Development of primary standard gas mixtures containing 10 μmol/mol oxygen in nitrogen with verification by a two-oven GC-TCD system for effective separation of oxygen from argon in presence of plenty of nitrogen
F. Pavese, Final Report of the International Intercomparison of fixed points by means of sealed cells: 13.81 K to 90.686 K, Monograph 84/4 of Bureau International des Poids et Mesures, BIPM Sèvres (1984), pp. 219
10.1088/0026-1394/20/4/002 F. Pavese, J. Ancsin, D.N. Astrov, J. Bonhoure, G. Bonnier, G.T. Furukawa, R.C. Kemp, H. Maas, R.L. Rusby, H. Sakurai, Ling Shankang, An International Intercomparison of fixed points by means of sealed cells in the range 13.81 K to 90.686 K, Metrologia 20 (1984), 127-144.
Adv. Cryo. Eng. Pavese 33 1039 1988 Evidence of unreliability of factory analyses of argon impurity in oxygen
Pavese vol 6 251 1992 Long-term stability of permanent realizations of the triple point of gases in metal sealed cells
F. Pavese, G.F. Molinar, Modern gas-based temperature and pressure measurements, International Monograph Series on Cryogenic Engineering, Plenum Publ.Co., New York, 1st Edition (1992) and 2nd Edition (2012), pp.520.
C. Rhee, D. Chi, K.H. Kang, K.S. Gam, Y.G. Kim, J.W. Hahn, S.N, Park, Document CCT/93-31.
Szmyrka-Grzebyk 1552 204 2013 The β - γ transition of oxygen as secondary fixed point
IJOT Steur 38 2 20 2017 Evidence for argon content in pure oxygen from thermal data
10.1007/s10765-019-2582-5 P.P.M. Steur, Inseok Yang, F. Pavese, The effect of argon content on the β-γ transition of oxygen, TEMPMEKO 2019, June 2019, ChengDu, China, submitted to International Journal of Thermophysics.
Pavese 217 1982 Ten years of research on sealed cells for phase transition studies of gases at IMGC
Cryogenics Lipiński 36 921 1996 10.1016/S0011-2275(96)00074-4 Hysteresis effect in the α-β transition of solid oxygen
Szmyrka-Grzebyk 105 1997 Proc Tempmeko Evidence of anomalies in the solid-solid phase transitions of solid oxygen and impurity detection
A. Szmyrka-Grzebyk, L. Lipinski, H. Manuszkiewicz, A. Kowal, P.P.M. Steur, 2nd International Seminar and Workshop on Low-Temperature Thermometry, Wroclaw (2003), 119-125.
10.1063/1.3117963 A. Szmyrka-Grzebyk, A. Kowal, Fizika Nizkich Temperatur (in Polish), 35 (4) 2009, 427-432.
Metrologia Pavese 14 93 1978 10.1088/0026-1394/14/3/001 The triple point of argon and oxygen
Pavese 167 2003 Temperature, Its Measurement and Control in Science and Industry Century stable cryogenic temperature fixed points: problems solved and problems to be solved
Metrologia Pavese 47 499 2010 10.1088/0026-1394/47/5/001 Comparison with U ≈ 50 μK of neon samples of different isotopic composition
Pavese 161 2003 Temperature, Its Measurement and Control in Science and Industry “MULTICELLS”: A European Project on Cryogenic Temperature Fixed Points in Sealed Cells
Int. J. Thermophys. Fellmuth 32 161 2010 10.1007/s10765-010-0883-9 Investigation on the parameters of sealed triple-point cells for cryogenic gases
Metrologia Fellmuth 42 171 2005 10.1088/0026-1394/42/4/001 Isotopic and other influences on the realization of the triple point of hydrogen
F. Pavese, I. Peroni, F. Sparasci, P.P.M. Steur, D. Ferri and A. Pugliese, A closed-cycle refrigerator for realizing low temperature fixed points, In: 2nd International Seminar and Workshop on Low-Temperature Thermometry (2003), Wroclaw, 102-107.
Metrologia Steur 56 2019 10.1088/1681-7575/aaee3a Comparison of xenon triple point realizations
Pavese 1552 192 2013 Dependence of the triple point temperature of neon on isotopic composition and its implications for the ITS-90
J. Low Temp. Phys. Fagerstroem 1 3 1969 10.1007/BF00628329 The specific heat of solid oxygen
Phys. Rep. Freiman 401 165 2004 10.1016/j.physrep.2004.06.002 Solid oxygen
J. Res. Nat. Bur. Standards Hoge 44 321 1950 10.6028/jres.044.029 Vapor pressure and fixed points of oxygen and heat capacity in the critical region
Physica Muijlwijk 43 475 1969 10.1016/0031-8914(69)90179-7 The temperatures of the transition points in oxygen
Kemp 4 217 1972 Temperature, its Measurement and Control in Science and Industry The transition temperatures of solid oxygen
Phys. Conf. Series Ancsin 26 57 1975 Crystalline transformation of oxygen
Metrologia Bedford 33 133 1996 10.1088/0026-1394/33/2/3 Recommended values of temperature on the International Temperature Scale of 1990 for a selected set of secondary reference points
Metrologia Ancsin 1973 10.1088/0026-1394/9/1/007 Dew point, boiling points and triple points of “pure” and impure oxygen
Metrologia Compton 12 101 1976 10.1088/0026-1394/12/3/003 Realization of the boiling and triple points of oxygen
해당 논문의 주제분야에서 활용도가 높은 상위 5개 콘텐츠를 보여줍니다.
더보기 버튼을 클릭하시면 더 많은 관련자료를 살펴볼 수 있습니다.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.