NTIS 바로가기Physica medica : European journal of medical physics, v.70, 2020년, pp.1 - 9
Cho, Sanghoon (Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST)) , Lim, Sunho (Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST)) , Kim, Changhwan (Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST)) , Wi, Sunhee (Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST)) , Kwon, Taejin (Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST)) , Youn, Won Sik (Department of Research & Development, JPI Healthcare, Co., Ltd.) , Lee, Sang Hyun (Department of Research & Development, JPI Healthcare, Co., Ltd.) , Kang, Bo Sun (Department of Radiological Science, Konyang University) , Cho, Seungryong (Department of Nuclear and Quantum Engineering, Korea Advanced Institute)
Abstract Purpose Anti-scatter grids suppress the scatter substantially thus improving image contrast in radiography. However, its active use in cone-beam CT for the purpose of improving contrast-to-noise ratio (CNR) has not been successful mainly due to the increased noise related to Poisson statis...
Med Phys Siewerdsen 28 2 220 2000 10.1118/1.1339879 Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter
Med Phys Siewerdsen 27 8 1903 2000 10.1118/1.1286590 Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography)
Phys Med Biol Sun 55 6695 2010 10.1088/0031-9155/55/22/007 Improved scatter correction using adaptive scatter kernel superposition
Med Phys Ning 31 5 1195 2004 10.1118/1.1711475 X-ray scatter correction algorithm for cone beam CT imaging
Phys Med Biol Poludniowski 54 3847 2009 10.1088/0031-9155/54/12/016 An efficient Monte-Carlo algorithm for scatter correction in keV cone-beam CT
Phys Med Biol Kim 60 5971 2015 10.1088/0031-9155/60/15/5971 Data consistency-driven scatter kernel optimization for x-ray cone-beam CT
10.1118/1.2148916 Siewerdsen JH, Daly MJ, Bakhtiar B, Moseley DJ, Richard S, Keller H, Jaffray DA. “A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT,” Med. Phy. 33(1), pp. 187-197.
Microsyst Technol Tang 4 187 1998 10.1007/s005420050128 Anti-scattering X-ray grid
Med Phys Siewerdsen 31 12 3506 2004 10.1118/1.1819789 The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors
Proc SPIE Med Image Singh 9033 2014 Limitations of anti-scatter grids when used with high resolution image detectors
Med Phys Schafer 39 1 153 2012 10.1118/1.3666947 Antiscatter grids in mobile C-arm cone-beam CT: effect on image quality and dose
Med Phys Abbas 40 11 2013 10.1118/1.4825096 Effects of sparse sampling schemes on image quality in low-dose CT
IEEE Trans Nucl Sci Lee 63 5 2540 2016 10.1109/TNS.2016.2604343 Moving beam-blocker-based low-dose cone-beam CT
IEEE Trans Med Image Lee 36 12 2578 2017 10.1109/TMI.2017.2765760 A feasibility study of low-dose single-scan dual-energy cone-beam CT in many-view under-sampling framework
IEEE Nucl Sci Conf Rec Sidky 5 2904 2006 Accurate image reconstruction in circular cone-beam computed tomography by total variation minimization: a preliminary investigation
Phys Med Biol Persson 46 853 2001 10.1088/0031-9155/46/3/318 Total variation norm for three-dimensional iterative reconstruction in limited view angle tomography
IEEE Nucl Sci Conf Rec Sidky 5 3526 2007 Image reconstruction from few views by non-convex optimization
Phys Med Biol Sidky 53 17 119 2006 Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization
Appl Math Optim Grasmair 62 3 323 2010 10.1007/s00245-010-9105-x Anisotropic total variation filtering
Phys Med Biol Chen 58 2119 2013 10.1088/0031-9155/58/7/2119 A limited-angle CT reconstruction method based on anisotropic TV minimization
The Phantom Laboratory, “Catphan 500 and 600 manual,” Salem, NY, The Phantom Laboratory, 2006.
J Opt Soc Am A Feldkamp 1 612 1984 10.1364/JOSAA.1.000612 Practical cone-beam algorithm
IEEE Comput Vis Pattern Recogn Buades 2005 A non-local algorithm for image denoising
Med Phys Samei 46 11 e735 2019 10.1002/mp.13763 Performance evaluation of computed tomography systems: summary of AAPM Task Group 233
Med Phys Alexeev 45 2 529 2018 10.1002/mp.12724 Two-dimensional antiscatter grid: a novel scatter rejection device for Cone-beam computed tomography
IEEE Trans Rad Plas Med Sci Lee 3 2 109 2019 10.1109/TRPMS.2018.2867611 Deep-neural-network based sinogram synthesis for sparse-view CT image reconstruction
Han Y, Yoo J, Ye JC. “Deep residual learning for compressed sensing CT reconstruction via persistent homology analysis.” [Online]. Available: https://arxiv.org/abs/1611.06391, 2016.
J Nondestruct Eval Maier 37 3 57 2018 10.1007/s10921-018-0507-z Deep scatter estimation (DSE): accurate real-time scatter estimation for X-ray CT using a deep convolutional neural network
해당 논문의 주제분야에서 활용도가 높은 상위 5개 콘텐츠를 보여줍니다.
더보기 버튼을 클릭하시면 더 많은 관련자료를 살펴볼 수 있습니다.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.