NTIS 바로가기Sensors and actuators. A, Physical, v.310, 2020년, pp.112080 -
Piao, Chunguang (Institute of Advanced Machines and Design, Seoul National University) , Yang, Xiongwei (State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace, Xi’an Jiaotong University) , Kweun, Joshua Minwoo (Department of Mechanical and Aerospace Engineering, Seoul National University) , Kim, Hyunseok (Department of Mechanical and Aerospace Engineering, Seoul National University) , Park, Hyungmin (Institute of Advanced Machines and Design, Seoul National University) , Cho, Seung Hyun (Center for Safety Measurement, Korean Research Institute of Standards and Science) , Kim, Yoon Young (Institute of Advanced Machines and Design, Seoul National University)
Abstract A non-invasive ultrasonic flowmeter transmits a shear wave into the wall of the pipe hosting the fluid. The shear wave is typically generated through a plastic wedge by the mode conversion of a longitudinal wave excited by a PZT element. Because of a big impedance mismatch between a plasti...
Lynnworth 245 1989 Ultrasonic Measurements for Process Control
Meas. Sci. Technol. Hauptmann 13 8 73 2002 10.1088/0957-0233/13/8/201 Application of ultrasonic sensors in the process industry
Ultrasonics Lynnworth 44 1371 2006 10.1016/j.ultras.2006.05.046 Ultrasonic flowmeters: half-century progress report, 1955-2005
Measurement Dell’Isola 20 2 75 1997 10.1016/S0263-2241(97)00016-X Measurement of high-pressure natural gas flow using ultrasonic flowmeters
Ultrasonics Zhou 82 145 2018 10.1016/j.ultras.2017.07.010 Multipath ultrasonic gas flow-meter based on multiple reference waves
Ultrasonics Chen 54 1 285 2014 10.1016/j.ultras.2013.06.001 Realization of a multipath ultrasonic gas flowmeter based on transit-time technique
IEEE Trans. Instrum. Meas. Mahadeva 58 5 1602 2009 10.1109/TIM.2009.2012954 Further studies of accuracy of clamp-on transit-time ultrasonic flowmeters for liquids
IEEE Trans. Instrum. Meas. Xiaotang Gu 68 1 65 2019 10.1109/TIM.2018.2834118 The effect of internal pipe wall roughness on the accuracy of clamp-on ultrasonic flowmeters
IEEE Trans. Instrum. Meas. Millan-Blasco 66 11 2845 2017 10.1109/TIM.2017.2731018 Zero-flow offset variation in ultrasonic clamp-on flowmeters due to inhomogeneity and nonlinearity of pipe materials
Sens. Actuators A Phys. Wang 298 2019 10.1016/j.sna.2019.111585 Wedge design for high-temperature ultrasonic flow rate measurement
IEEE Sens. J. Kim 17 17 5741 2017 10.1109/JSEN.2017.2727340 Transit time difference flowmeter for intravenous flow rate measurement using 1-3 piezoelectric composite transducers
Busch-Vishniac 1999 Electromechanical Sensors and Actuators
Appl. Acoust. Kim 58 211 1999 10.1016/S0003-682X(98)00039-5 Vibroacoustic characteristics of ultrasonic cleaners
Miu 1993 Mechatronics: Electromechanics and Contromechanics
IEEE Trans. Sonics Ultrason. Meitzler 3 233 1973 10.1109/T-SU.1973.29750 Definition and measurement of radial mode coupling factors in piezoelectric ceramic materials with large variations in Poisson’s ratio
Ultrasonics Piao 74 72 2017 10.1016/j.ultras.2016.09.021 Vibration characteristics of an ultrasonic transducer of two piezoelectric discs
Noise Control Eng. J. Piao 64 444 2016 10.3397/1/376392 Vibration characteristics of a piezoelectric transducer laminated with piezoelectric disks
Phys. Rev. B Yang 98 14 2018 10.1103/PhysRevB.98.144110 Asymptotic theory of bimodal quarter-wave impedance matching for full mode-converting transmission
Appl. Phys. Lett. Yang 115 7 2019 10.1063/1.5109758 Monolayer metamaterial for full mode-converting transmission of elastic waves
Phys. Rev. Lett. Kweun 118 20 2017 10.1103/PhysRevLett.118.205901 Transmodal Fabry-Perot resonance: theory and realization with elastic metamaterials
Sci. Rep. Yang 8 1 1 2018 Theory for perfect transmodal Fabry-Perot interferometer