NTIS 바로가기한국지진공학회논문집 = Journal of the Earthquake Engineering Society of Korea, v.6 no.3 = no.25, 2002년, pp.87 - 93
김진구 (성균관대학교 건축공학과) , 방성혁 (한국기술신용정보)
A procedure for figuring out proper amount of additional viscous damping required to keep the inelastic deformation of a plan-wise asymmetric structure within a given target performance point was developed. To this end the behavior of an asymmetric nonlinear structure after yielding is investigated....
Hejal, R. and Chopra, A. K., “Earthquake response of torsionally-coupled frame buildings,” J. Struct. Eng., ASCE, Vol. 115, 1989, pp. 834-851.
Chandler, A. M. and Duan, X. N., “A modified static procedure for the design of torsionally unbalanced multistory frame buildings,” Earthquake Eng. and Struct. Dyn., Vol. 22, 1993, pp. 447-462.
De La Llera, J. C. and Chopra, A. K., “A simplified model for analysis and design of asymmetric-plan buildings,” Earthquake Eng. and Struct. Dyn., Vol. 24, 1995, pp. 573-594.
Bugeja, M. N., Thambiratnam, D. P., and Brameld, G. H., “The influence of stiffness and strength eccentricities on the inelastic earthquake response of asymmetric structures,” Engineering Structures, Vol. 21, 1999, pp. 856-863.
Goel, R. K., “Seismic behavior of asymmetric buildings with supplemental damping,” Earthquake Eng. and Struct. Dyn., Vol. 29, 2000, pp. 461-480.
Paulay, T., “Torsional mechanisms in ductile building systems,” Earthquake Engineering and Structural Dynamics, Vol. 27, 1998.
ATC, “Seismic evaluation and retrofit of concrete buildings,” ATC-40, Applied Technology Council, Redwood City, California, 1996.
SEAOC, “Tentative guidelines for performance-based seismic engineering,” SEAOC Blue Book, Structural Engineers Association of California, 1999.
Chopra, A. K., Dynamics of Structures : Theory and Applications to Earthquake Engineering, Prentice Hall, Inc., Englewood Cliffs, New Jersey, 1995.