The objectives of the present study are to numerically and experimentally investigate the steady and pulsatile flow phenomena in the circular tubes, to quantitatively compare the flow characteristics of Newtonian and non-Newtonian fluids, and to find meaningful hemodynamic information through the fl...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Banerjee, R. K., 1992, 'A Study of Pulsatile Flows with Non-Newtonian Viscosity of Blood in Large Arteries,' Ph. D. Thesis, Drexel University
Cho, Y. I. and Kensey, K. R., 1989, 'Effects of the Non-Newtonian Viscosity of Blood on Hemodynamics of Diseased Arterial Flows,' Advances in Bioengineering, Vol. 15, pp. 147-158
Nerem, R. M., 1992, 'Vascular Fluid Mechanics, the Arterial Wall, and Atherosclerosis,' Journal of Biomechanical Engineering, Vol. 114, pp. 274-282
Kwon, C. H. and Kim, Y. H., 2001, 'Fluid-Structure Interaction in the Axisymmetric Abdominal Aortic Aneurysm by Pulsatile Flow,' J. Biomed. Eng. Res., Vol. 2, No. 1, pp 59-68
Shim, E. B. 2000, 'Numerical Analysis of Flow in a Compliant Tube Considering Fluid-Wall Interaction,' J. Biomed. Eng. Res., Vol. 21, No. 4, pp. 391-401
Adrian, R. J., 1991, 'Particle-Imaging Techniques for Fluid Mechanics,' Annu. Rev. Fluid Mech., Vol. 23, pp. 261-304
Suh, S. H., Choi, Y., Roh, H. W., and Doh, D. H., 1999, 'Flow Analysis in the Bifurcated Duct with PIV System and Computer Simulation,' Trans. of KSME (B), Vol. 23, No. 1, pp. 123-180
Doh, D. H., and Choi, S. H., Hong, S. D, Baek, S. T., Kobayashi, T., and Saga, T., 1998, 'Quantitative Real Time Measurement of an Acoustic Energy Flow by PIV,'VSJ-SPIE98, pp. 268-269
Ni, X., Liu, S., Joyce, M. J., and Grewal, P. S., 1995, 'A Study of Velocity Vector Profile and Strain Rate Distribution for Laminar and Oscillatory Flows in a Baffled Tube Using Particle Image Velocimetry,' Journal of Flow Visualization and Image Processing, Vol. 2, pp. 135-147
Nichols, W. W. and O'Rourke, M. F., 1990, 'McDonalds' Blood Flow in Arteries, 3rd Ed., Lea & Febiger, Philadelphia, pp. 398-420
Biro, G. P., 1982, 'Comparison of Acute Cardiovascular Effects and Oxygen Supply Following Haemodilution with Dextran, Stroma-Free Haemoglobin Solution and Fluorocarbon Suspension,' Cardovascular Res. 16, pp. 194-204
Skalak, R., Keller, S. R., and Secomb, T. W., 1981, 'Mechanics of Blood Flow,' Journal of Biomechanical Engineering, Vol. 103, pp. 102-115
Suh, S. H., Yoo, S. S., and Roh, H. W., 1994, 'Numerical Analysis of Branch Flows for Newtonian and Non-Newtonian Fluids,' Trans. of KSME Vol. 18, no. 10, pp. 2762-2772
Lowe, M. L. and Kutt, P. H., 1992, 'Refraction Through Cylindrical Tubes,' Experiments in Fluids, Vol. 13, pp. 315-320