NTIS 바로가기방사선방어학회지 = Radiation protection : the journal of the Korean association for radiation protection, v.29 no.2, 2004년, pp.105 - 115
정광호 (가톨릭의대 의공학교실) , 서태석 (가톨릭의대 의공학교실) , 조병철 (한림성심병원 방사선종양학과)
The Monte Carlo simulation requires very much time to obtain a result of acceptable accuracy. Therefore we should know the optimum number of history not to sacrifice time as well as the accuracy. In this study, we have investigated the effects of statistical uncertainties of the photon dose calculat...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
P. Andero, 'Monte Carlo techniques in medical radiation physics', Phys. Med. Bio., 36, 861-920(1991)
C.M. MA, B.A. Faddegon, D.W.O. Rogers and TR Mackie, 'Accurate characterization of Monte Carlo calculation electron beams for radiotherapy', Med. Phys., 24 401-416(1997)
J. Sempau, S.J. Wilderman and A.F. Bielajew, 'DPM : a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planningdose calculations', Phys: Med. BioI., 45, 2263-2291(2000)
P.J. Keall, J.V. Siebers, R. Jeraj and R. Mohan, 'The effect of dose calculation uncertainty on the evaluation of radiotherapy plans', Med. Phys., 27(3) 478-484(2000)
I. Kawrakow and M. Fippel, 'Investigation of variance reduction techniques for Monte Carlo photon dose calculation using XVMC', Phys. Med. Biol,. 45, 2163-2184(2000)
F.M. Buffa and A.E. Nahum, 'Monte Carlo dose calculations and radiobiological modelling : analysis of the effect of the statistical noise of the dose distribution on the probability of tumor control', Phys. Med. Biol., 45, 3009-3023(2000)
F. Salvat, J.M. Fernandez-Varea, J. Sempau, 'PENELOPE, a code system for Monte Carlo simulation of electron and photon transport', PENELOPE user manual, 4-33, Universitat de Baecelona, Barcelona, Spain(2003)
J. Sempau, A. Sanchez-Reyes, F. Salvat, H.O.B. Tahar, S.B. Jiang and J.M FernandezVerea, 'Monte Carlo simulation of electron beams from an accelerator head using PENELOPE', Phys. Med. Biol., 46, 1163-1186(2001)
B.R.B. Walters, I. Kawrakow and D.W.O. Rogers, 'History by history statistical estimators in the BEAM code system', NRCC Report PIRS-0791,National Research Council of Canada, Ottawa, Canada(2002)
I. Kawrakow and D.W.O. Rogers, 'The EGSnrc code system : Monte Carlo simulation of electron and photon transport', Technical report PIRS-701, National Research Council of Canada, Ottawa, Canada(2000)
C.M. Ma, J.S. Li, T. Pawlicki, S.B. Jiang, J. Deng, M.C.Lee, T. Koumrian, M. Luxton and S. Brain, 'A Monte Carlo dose calculation tool for radiotherapy treatment planning' Phys. Med: Biol., 47, 1671-1689(2002)
I. Kawrakow and M. Fippel, 'VMC++, a fast MC algorithm for radiation treatment planning', Proceedings of The Use of Computers in Radiotherapy, Xlllth Int'1 Conf., Heidelberg, 126-128, SpringerVerlag, Heidelberg(2000)
D.W.O. Rogers and A.F. Bielajew, 'Monte Carlo techniques of electron and photon transport for radiation dosimetry', in:The dosimetry of ionizing radiation vol.3, K.R. Kase, B.E. Barngard and F.H. Attix, 427-539, Academic Press, New York(1990)
D.W.O. Rogers and R. Mohan, 'Questions for comparison of clinical Monte Carlo codes', Proceedings of The Use of Computers in Radiotherapy, XIIIth Int'l Conf., Heidelberg, 120-122, Springer-Verlag, Heidelberg(2000)
DW.O. Rogers, B.A.F addegon, G,X, Ding, C.M. Ma. and J.We, 'BEAM:A Monte Carlo code to simulate radiotherapy treatment units', Med. Phys., 22, 503-524(1995)
S.B. Jiang, T. Pawlicki and C.M. Ma, 'Removing the effect of statistical uncertainty on dose-volume histogram from Monte Carlo dose calculations', Phys. Med. Biol., 45, 2151-216l(2000)
I. Kawrakow, 'On the de-noising of Monte Carlo calculated dose distributions', Phys. Med. Biol., 47, 3087-3103(2002)