NTIS 바로가기大韓機械學會論文集. Transactions of the Korean Society of Mechanical Engineers. A. A, v.28 no.8 = no.227, 2004년, pp.1183 - 1189
손상욱 (한국과학기술원 기계공학과) , 최요한 (한국과학기술원 기계공학과) , 이승섭 (한국과학기술원 기계공학과)
A novel cell count method, which can improve the count efficiency and reduce contamination problem, was presented using micro lattice engraved on culture dish. The micro lattice has feature of
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Coulter, W. H., 1956, 'High Speed Automatic Blood Cell Counter and Cell Size Analyzer,' Proc. National Elecuonics Conf. 12, pp.1034-1040
Sergent-Tanguy, S., Chagneau, C., Neveu, I. and Naveilhan, P., 2003, 'Fluorescent Activated Cell Sorting (FACS): a Rapid and Reliable Method to Estimate the Number of Neurons in a Mixed Population,' J. Neuroscience Methods, Vol. 129, pp. 73-79
Asai, J., Suzuki, R, Fujimoto, T., Nagashima, G, Miyo, T., Takahashi, M. and Hokaku, H., 1997, 'Fluorescent Automatic Cell Sorter (FACS) and Irrnnunohistological Investigations of CD-68 Positive Mononuclear Cell Infiltrates in Meningiomas,' Clinical Neurology and Neurosurgery, Vol. 99, pp. S133-S134
Benjumovich, M. S., 2002, 'Use of Poisson Units in Radiology,' Radiation Physics and Chemistry, Vol. 66, pp. 7-9
Tezcaner, A., Bugra, K. and Hasirci, V., 2003, 'Retinal Pigment Epithelium Cell Culture on Surface Modified Poly (hydroxybutyrate-co-hydroxyvalerate) Thin Films,' Biomaterials, Vol. 24, pp. 4573-4583
Freshney, R. I., 1994, 'Culture of Animal Cells,' 3rd ed., Wiley-Liss, pp. 243-252
Johnson, D. W., Jeffries, A., Minsek, D. W. and Urditch, R. J., 'Improving the Process Capability of SU-8,' www.microchem.com/resources/materials.htm.
Han, M. H., Huh, J. -K., Lee, S. S. and Lee, S. -J., 2002, 'Fabrication of a Micro-Riblet Film Using MEMS Technology and Its Application to Drag Reduction,' Transactions of the KSME, B, Vol. 26, No.7, pp. 991-996
Jo, B. -H., Van Lerberghe, L. M., Motsegood, K. M. and Beebe, D.J., 2000, 'Three-Dimensional MicroChannel Fabrication in Polydimethylsiloxane (PDMS) Elastomer,' J. Microelectromech. Sys., Vol. 9, No.1, pp.76-81
Kaji, H., Nishizawa, M. and Matsue, O., 2003, 'Localized Chemical Stimulation to Micropatterned Cells Using Multiple Laminar Fluid Flows,' Lab on a chip, Vol. 3, pp. 208-211
Ephrussi, A. and Pourquie, O., 2003, 'Pattern Formation and Developmental Mechanisms from Cell Patterning to Organogenesis,' Current Opinion in Genetics & Development, Vol. 13, pp. 323-325