NTIS 바로가기上下水道學會誌 = Journal of Korean Society of Water and Wastewater, v.18 no.3, 2004년, pp.351 - 356
Selecting appropriate G values in flocculator operation is important to produce high quality filter effluent in water treatment plants. However, misunderstanding and misleading of G calculation for the case of having power sources more than one or many paddles with one power source in a flocculation...
Camp, T.R. and Stein, P.C. (1943) Velocity Gradients and Internal Work in Fluid Motion, J. Boston Soc. Civil Engineers, 30, pp. 219-237
Camp, T.R. (1955) Flocculation and Flocculation Basins, Trans., ASCE, 120, pp. 1-16
Clark, M.M. (1985) Critique of Camp and Stein's rms velocity gradient, Jour. of Environ. Engineering, ASCE, 111(6), pp. 741-764
Han, M., and Lawler, D.F. (1992)The (relative) Insignificance of G in Flocculation, JAWWA, 84(10), pp. 79-91
Johnson, C.P., Li, X.Y., and Logan, B.E., (1996) Settling Velocities of Fractal Aggregates, Environ, Sci. Technol., 30, pp.1911-1918
Kawamura, S. (2000) Integrated Design and Operation of Water Treatment Facilities. 2nd Ed. p. 131, John Wiley & Sons, Inc., New York
Li, X.Y., and Yuan, Y. (2002) Settling Velocities and Permeabilities of Microbial Aggregates, Water Research, 36, pp.3110-3120
O'Melia, C.R. (1978) Coagulation in Water Treatment in The Scientific Basis of Flocculation, K.J. Ives ed., p. 73, KLEWAR Academic Publishers, The Netherlands
Smoluchowski, M. (1917) Versuch einer mathematischen Theorie der Koagulationskinetic kolloider Losunger, Zeitschrift Physicalische Chemie, 92, pp. 129