최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기방사선방어학회지 = Radiation protection : the journal of the Korean association for radiation protection, v.30 no.3, 2005년, pp.113 - 119
장기원 (방사선 안전 신기술 연구센터) , 이춘식 (방사선 안전 신기술 연구센터) , 권정완 (한양대학교 원자력공학과) , 이재기 (한양대학교 원자력공학과)
The computed tomogrpahy(CT) provides a high quality in images of human body but contributes to the relatively high patient dose. The frequency of CT examination is increasing and, therefore, the concerns about the patient dose are also increasing. In this study the experimental determination of pati...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
ICRP, Managing Patient Dose in Computed Tomography, International Commission on Radiological Protection, ICRP Publication 87 (2001)
NRPB, Survey of CT Practice in the UK Part 3: Normalised Organ Doses Calculated using Monte Carlo Techniques, National Radiological Protection Board, NRPB-R250(1991)
GSF, The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods, Part VI: Organ doses from tomographic examinations, Gesellschaft Fur Strahlen-und Umweltforschung mbH, GSF Rep 30/91(1991)
K.K.L. Fung, W. B. Gilboy, 'Anode heel effect on patient dose in lumbar spine radiography,' Br. J. Radiol, 73, 531-536 (2000)
J. Geleijns, J. G. Van Unnik, J. Zoeteliff, D. Zweers, J. J. Broerse, 'Comparison of two methods for assessing patient dose from computed tomography,' Br. J. Radiol, 67, 360-365(1994)
A. Calzado, S. Ruiz Sanz, M. Melochor, E. Vano, 'A comparison of measured and calculated organ doses from CT examinations,' Radial Prot. Dosim, 57 (1-4), 381-385(1995)
ICRU, Tissue Substitutes in Radiation Dosimetry and Measurement, International Commission on Radiation Units and Measurements, ICRU Publication 44(1989)
ICRP, Recommendations of the InternatCommission on Radiological Protectionional , International Commission on Radiological Protection, ICRP Publication 60(1991)
W. S. Snyder, M. R. Ford, G. G. Warner, 'Estimates of Specific Absorbed Fraction for Photon Sources Uniformly Distributed in Various Organs of a Heterogeneous Phantom,' Society of Nuclear Medicine, New York, MIRD Pamphlet No. 5. Revised (1978)
J. L. Muniz et al, 'A study of LiF GR-200 for radiotherapy mailed dosimetry,' Phys. Med. Biol, 42, 2569-2576(1997)
J. L. Ioppolo, R. I. Price, T. Tuchyna, C. E. Buckley, ' Diagnostic x-ray dosimetry using Monte Carlo simulation,' Phys. Med Biol., 47, 1707-1720(2002)
K. Cranley, B. J. Gilmore, G. W. A. Fogarty, L. Desponds, Catalogue of Diagnostic X-ray Spectra and Other Data, The Institute of Physics and Engineering in Medicine Report No.78(1997)
J. H. Hubbell, S. M. Seltzer, 'Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients,' National Institute of Standards and Technology, Gaithersburg (at http://phvsics.nist.gov/PhvsRefData/XravMassCoef /cover.html)(1996)
G. Drexler, 'Verlauf der lonendosis an Grenzschichten, In Microdosimetry', Proc. Symp. Microdosimetry, Ispra, 13-15, EIR3747 d-f-e, European Communities, Brussels(1968)
Rosenstein M., 'Organ Doses in Diagnostic Radiology,' US Department of Health, Education and Welfare, Bureau of Radiological Health BRH Tech. Publ., DA 76-8030(1976)
Michael F. McNitt-Gray, Christopher H. Cagnon, 'Radiation dose in Sprial CT: The relative effects of collimation and pitch,' Med. Phys., 26(3), 409-414(1999)
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.