NTIS 바로가기한국지진공학회논문집 = Journal of the Earthquake Engineering Society of Korea, v.9 no.2 = no.42, 2005년, pp.1 - 6
이상현 (서울대학교 공학연구소) , 민경원 (단국대학교 건축대학 건축공학과) , 이명규 (단국대학교 건축대학 건축공학과)
The purpose of this paper is to evaluate the performance of an MR fluid damper for seismic vibration control of a structure in terms of equivalent linear damping based on linearization technique and to experimentally verify the results from linearization technique by comparing them to those from sys...
Dyke, S.J., Spencer, Jr. B.F., Sain, M.K. and Carlson, J.D., 'Modeling and control of magnetorheological dampers for seismic response reduction,' Smart Materials and Structures, Vol.5, pp.565-575
Jansen, L.M. and Dyke S.J., 'Semi-active control strategies for MR dampers: comparative study,' Journal of Engineering Mechanics, ASCE Vol.126, No.8, 2000, pp. 795-803
Proppe, C., Pradlwarter, H.J. and Schueller, G.I., 'Equivalent linearization and Monte Carlo simulation in stochastic dynamics,' Journal of Probabilistic Engineering Mechanics, Vol.18, 2003, pp.1-15
Caughy, T.K., 'Random excitation of a system with bilinear hysteresis', Journal of Applied Mechanics, ASME, Vol.27,1960, pp.649-652
Li, C. and Reinhorn, L.C., 'Experimental and analytical investigation of seismic retrofit of structures with supplemental damping: part II-friction devices,' Technical Report NCEER-95-0009, State University of New York at Buffalo, Buffalo, Ny, 1995
Barber, T.T and Wen, Y.K, 'Random vibration of hysteretic, degrading systems,' Journal of the Engineering Mechanics Division, Vol.107, No. EM6, 1981, pp.1069-1087
Yalla, S.K., 'Liquid dampers for mitigation of structural response : theoretical development and experimental validation,' Ph.D dissertation, University of Notre Dame, Indiana, 2001
Chang, K.C., Lai, M.L., Soong, T.T., Hao, D.S. and Yeh, Y.C., 'Seismic behavior and design guidelines for steel frame structures with added viscoelastic dampers,' Technical Peport NCEER-93-0009, National Center for Earthquake Engineering Research, Buffalo, N.Y., 1993
Lee, S.H., Min, K.W., Kim, J. K. and Hwang, J.S., 'Equivalent damping ratio of a structure with added dampers,' Engineering Structures, Vol.26, No.3, 2004, pp.335-346
문석준, 정정훈, 김병현, 'Bouc-Wen 모델을 이용한 면진장치의 최적설계', 한국지진공학회 추계학술발표회논문집, Vol.7, No.2, 2003, pp.395-400
Friswell, M. I. and Mottershead, J. E., Finite Element Model updating in Structural Dynamics, Kluwer Academic Publishers, Boston, London, 1995
Yang, G., 'Large-scale magnetorheological Fluid Damper for Vibration Mitigation: Modeling, Testing and Control,' Ph.D dissertation, University of Notre Dame, Indiana, 2001
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
오픈액세스 학술지에 출판된 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.