NTIS 바로가기대한치과교정학회지 = Korean journal of orthodontics, v.36 no.1 = no.114, 2006년, pp.55 - 62
김종완 (서울대학교 치과병원 교정과) , 조일식 (서울대학교 치과병원 교정과) , 이신재 (서울대학교 치과대학 교정학교실) , 김태우 (서울대학교 치과대학 교정학교실) , 장영일 (서울대학교 치과대학 교정학교실)
Orthodontic mini-implants, despite its usefulness as anchorage, have some limits such as loosening. Therefore, various shapes and lengths have been studied. The aim of this study is to analyze the shape and length of mini-implants mechanically. The shapes of mini-implants (1.6 mm, Dual Top, Jeil Med...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Burstone CJ, Manhartsberger C. Precision lingual arches. Passive applications. J Clin Orthod 1988:22:444-51
Kuhlberg AJ, Burstone CJ, T-loop position and anchorage control. Am J Orthod Dentofacial Orthop 1997:112:12-8
Albrektsson T. Direct bone anchorage of dental implants. J Prosthet Dent 1983;50:255-61
Linkow LI. The endosseous blade implant and its use in orthodontics. Int J Orthod 1969:24:149-54
Block MS, Hoffman DR. A new device for absolute anchorage for orthodontics. Am J Orthod Dentofacial Orthop 1995;107:251-8
Wehrbein H, Feifel H, Diedrich P. Palatal implant anchorage reinforcement of posterior teeth: A prospective study. Am J Orthod Dentofacial Orthop 1999:116:678-86
Kanomi R. Mini-implant for orthodontic anchorage. J Clin Orthod 1997:31:763-7
Umemori M, Sugawara J, Mitani H, Nagasaka H, Kawamura H. Skeletal anchorage system for open-bite correction. Am J Orthod Dentofacial Orthop 1999:115:166-74
Kyung SH, Lim JK, Park YC. The use of miniscrew as an anchorage for the orthodontic tooth movement. Korean J Orthod 2001:31:415-24
Costa A, Raffainl M, Melsen B. Miniscrews as orthodontic anchorage: a preliminary report. Int J Adult Orthodon Orthognath Surg 1998:13:201-9
Himmlova L, Dostalova T, Kacovsky A, Konvickova S. Influence of implant length and diameter on stress distribution: a finite element analysis. J Prosthot Dent 2004:91:20-5
Kim JW, Ahn SJ, Chang YI. Histomorphometric and mechanical analyses of the drill-free screw as orthodontic anchorage. Am J Orthod Dentofacial Orthop 2005;128:190-4
Hermann I, Lekholm D, Holm S, Kultie C. Evaluation of patient and implant characteristics as potential prognostic factors for oral implant failures. Int J Oral Maxillofac Implants 2005;20:220-30
Martinez H, Davarpanah M, Missika P, Celletti R, Lazzara R. Optimal implant stabilization in low density bone. Clinical Oral Implant Research 2001;12:423-32
O'Sullivan D, Sennerby L, Meredith N. Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants. Clin Oral Implants Res 2004;15:474-80
Ueda M, Matsuki M, Jacobsson M, Tjellstrom A. Relationship between insertion torque and removal torque analyzed in fresh in temporal bone. Int J Oral Maxillofac Implants 1991;6:442-7
Zdeblick TA, Kunz DN, Cooke ME, McCabe R. Pedicle screw Pullout strength. Correlation with insertional torque. Spine 1993;18:1673-6
Ozawa T, Takahashi K, Yamagata M, Ohtori S, Aoki Y, Saito T, et al. Insertional torque of the lumbar pedicle screw during surgery. J Orthop Sci 2005;10:133-6
Sennerby L, Dasmah A, Larsson B, Iverhed M. Bone tissue responses to surface-modified zirconia implants: A histomorphometric and removal torque study in the rabbit. Clin Implant Dent Relat Res 2005;7 Suppl 1:S13-20
Steinemann S. The properties of titanium. In: Schoeder A, Sutter F, Buser D, Krekeler G editors. 2nd Edition, Oral Implantology. New York: Thieme Medical Publishers, Inc.; 1996. p. 38
Carano A, Lonardo P, Velo S, Incorvati C. Mechanical properties of three different commercially available miniscrews for skeletal anchorage. Prog Orthod 2005;6:82-97
Huiskes R, Nunamaker D. Local stresses and bone adaptation around orthopedic implants. Calcif Tissue Int 1984;36 Suppl 1:S110-7
Hansson S, Werke M. The implant thread as a retention element in cortical bone: the effect of thread size and thread profile: a finite element study. J Biomech 2003;36:1247-58
Palmer RM, Palmer PJ, Smith BJ, A 5-year prospective study of Astra single tooth implants. Clin Oral Implants Res 2000;11:179-82
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.