최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기International journal of precision engineering and manufacturing, v.7 no.3, 2006년, pp.60 - 65
Kang Sung-Hoon (Department of Mechanical Engineering, KAIST) , Kang Dong-Woo (Department of Mechanical Engineering, KAIST) , Gweon Dae-Gab (Department of Mechanical Engineering, KAIST) , Yoon Gwon-Ha (Department of Radiology, Wonkwang University School of Medicine) , Min Jin-Young (LISTEM Co, Ltd)
This paper proposes a new type of six degree-of-freedom fine positioner that can be used to align the condenser in X-ray microscopy precisely. The new concept was based on the requirements for an X-ray microscope. A proposed modeling method was used to obtain an optimal design, which was verified wi...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Takeuchi, A., Aoki, S., Yamamoto, K., Takano, H., Watanabe, N. and Ando, M., 'Full-field x-ray fluorescence imaging microscope with a Wolter mirror,' Review of Scientific Instruments, Vol. 71, No. 3, pp. 1279-1285, 2000
Ninorniya, K. and Hasegawa, M., 'Scanning photoelectron microscope with sub micron lateral resolution using a Wolter-type x-ray focusing mirror,' Journal of Vacuum Science Technology A, Vol. 13, No.3, pp. 1224-1228, 1995
Watanabe, N., Yamamoto, K., Takano, H., Ohigashi, T, Yokosuka, H., Aota, T and Aoki, S., 'X-ray fluorescence microtomography with a Wolter mirror system,' Nuclear Instruments and Methods in Physics Research A, Vol. 467-468, No.2, pp. 837-840, 2001
Aoki, S., Kumegawa, M., Watanabe, N., Ohigashi, T, Aota, T, Yamamoto, K., Yokosuka, H., Tanoue, R., Tsujita, Y and Anto, M., 'X-ray scattering microscope with a Wolter mirror,' Review of Scientific Instruments, Vol. 73, No.7, pp. 2629-2633, 2002
Hasagawa, M., Yoneyama, A. and Ninorniya, K., 'Soft x-ray scanning photoelectron microscope using Wolter-type focusing mirror,' Journal of Electron Spectroscopy and Related Phenomena, Vol. 80, pp. 361-364, 1996
Voss, J., 'The scanning soft X-ray microscope at Hasylab: imaging and spectroscopy of photoelectrons, photoluminescence, desorbed ions, reflected, scattered and transmitted light,' Journal of Electron Spectroscopy and Related Phenomena, Vol. 84, No. 1/3, pp. 29-44, 1997
Horikawa, Y, 'Consideration on the condenser for an imaging type Schwarzschild soft X-ray microscope,' Journal of Modern Optics, Vol. 40, No.2, pp. 289-298, 1993
Berglund, M., Rymell, L., Peuker, M., Wilhein, T and Hertz, H. M., 'Compact water-window transmission X-ray microscope,' Journal of Microscopy, Vol. 197, pp. 268-273, 1999
Matyi, R. J., Moran, P. D., Hagquist, W. W. D. and Volz, H. M., 'Alignment system for crossed parabolic x-ray mirrors,' Review of Scientific Instruments, Vol. 71, No.6, pp.2292-2295, 2000
Ryu, J. W., '6-Axis ultraprecision positioning mechanism design and positioning control,' Ph.D. dissertation, KAIST, Daejon, South Korea, 1997
Kang, D. W., 'The design and test of ultraprecision XY stage using leaf spring mechanism and voice-coil motor,' Masters dissertation, KAIST, Daejon, South Korea, 1997
Mohammadi Diniali, H. R., Zsombor-Murray, P. J. and Angeles, J., 'Singularity analysis of planar parallel manipulators,' Mech. Mach. Theory, Vol. 30, No.5, pp. 665-678, 1995
※ AI-Helper는 부적절한 답변을 할 수 있습니다.