NTIS 바로가기Journal of biomedical engineering research : the official journal of the Korean Society of Medical & Biological Engineering, v.28 no.1, 2007년, pp.132 - 138
장봉렬 (연세대학교 보건과학대학 의공학과) , 박호동 (연세대학교 보건과학대학 의공학과) , 이경중 (연세대학교 보건과학대학 의공학과)
MR(magnetic resonance) image of moving organ such as heart shows serious distortion of MR image due to motion itself. To eliminate motion artifacts, MRI(magnetic resonance imaging) scan sequences requires a trigger pulse like ECG(electro-cardiography) R-wave. ECG-gating using cardiac cycle synchroni...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
M.K. Laudon, J.G. Webster, R. Frayne, T.M. Grist, 'Minimizing interference from magnetic resonance imagers during electrocardiography,' Ieee Transactions on Biomedical Engineering, vol. 45, no. 2, pp.160-164, 1998
J. Felblinger, C. Lehmann, C. Boesch, 'Electrocardiogram acquisition during MR examinations for patient monitoring and sequence triggering,' Magnetic Resonance in Medicine, vol. 32, no. 4, pp. 523-529, 1994
R. Rokey, R.E. Wendt, D.L. Johnston, 'Monitoring of acutely ill patients during nuclear magnetic resonance imaging : Using of a time-varing filter electrocardiographic gating device to reduce gradient artifacts,' Magnetic Resonance In Medicine, vol. 6, no. 2, pp.240-245, 1988
A.N. Shetty, 'Supression of radiofrequency interference in cardiac gated MRI : A simple design,' Magnetic Resonance In Medicine, vol. 8, no. 1, pp.84-88, 1988
R.E. Wendt 3rd, R. Rokey, G.W. Vick 3rd, 'Electrocardiographic gating and monitoring in NMR imaging,' Magnetic Resonance Imaging, vol. 6, no. 1, pp.89-95, 1988
S. Jones, W. Jaffe, R. Alvi, 'Burns associated with electrocardiographic monitoring during magnetic resonance imaging,' Burns, vol. 22, no. 5, pp.420-421, 1996
S.J. Keens, A.S. Laurence, 'Burns caused by ECG monitoring during MRI imaging,' Anaesthesia, vol. 51, no. 12, pp.1188-1189, 1996
R.N. Dimick, L.W. Hedlund, R.J. Herfkens, E.K. Fram, J. UTZ, 'Optimizing electrocardiograph electrode placement for cardiacgated magnetic resonance imaging,' Invest Radiology, vol. 22, no. 1, pp.17-22, 1987
R. Abacherli, C. Pasquier, F. Odille, M. Kraemer, J.J. Schmid, J. Felblinger, 'Suppression of MR gradient artefacts on electrophysiological signals based on an adaptive real-time filter with LMS coefficient updates,' MAGMA, vol. 18, no. 1, pp.41-50, 2005
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
출판사/학술단체 등이 한시적으로 특별한 프로모션 또는 일정기간 경과 후 접근을 허용하여, 출판사/학술단체 등의 사이트에서 이용 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.